Ceiling diffuser VAL Model Description, areas of application et benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration and mode of operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aerodynamic data and scopes of application . . . . . . . . . . . . . . . . . . . . . . . . . . Diagrams - Horizontal and vertical airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Cooling and heating / examples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalogue to page 2

Ceiling diffuser Description, areas of application and benefits The VAL variable air diffuser includes an internal control dial which allows manual or motorized adjustment to adapt to diverse situations. The distinctive characteristics of the airflow allow installation of the diffuser recessed into the ceiling or suspended at heights of up to 15m with a feed flow which can reach 3000 m3/h. Areas of application - Individual offices - Administration areas - Large retail stores - Meeting rooms - Multi-purpose rooms - Cinemas - Sports rooms - Industrial halls - Conference or convention halls Benefits...

 Open the catalogue to page 3

Ceiling diffuser Configuration and mode of operation The VAL air diffuser comprises a valve (1), a throttle ring (2), a connecting frame (3) and a second control ring (4). The design of the outer rings gives a conical appearance. The different parts are attached to the main body (6) of the diffuser with spacers (5) forming a perfectly symmetrical unit. The valve is equipped with a regulating mechanism (7) which permits a manual vertical movement of the connecting frame (3). As an option, the diffuser can be motorized. Radial airflow When the connection plate is in the lower position, the flow...

 Open the catalogue to page 4

Ceiling diffuser Aerodynamic data and scopes of application Nominal size [-] Specification : Minimum ceiling height of 3m so that the airflow does not exceed 0.20 m / s in the occupied zone. The depth of penetration in heating mode y is ∆T = 10K (raised plate). Critical airflow trajectory ∆T = -8K (plate not raised) * The values LWA apply to the cooling and heating functions Ranges of application = minimum range of application = Optimal range of application = maximum range of application Subject to technical changes. Version 17 / 04 / 2015

 Open the catalogue to page 5

Ceiling diffuser VAL vertical airflow In the 50% radial / 50% axial position, the data will be corrected: LWA = LWA-3dB ∆Pt = ∆Pt x 0.61 Vertical airflow distance after conjunction (y[m]) VAL horizontal air flow In the case of ceiling level installation, speeds are multiplied by 1.4. Note: Acoustic power in dB (A) = Sound level NR +5 LWA [dB(A)] = The absorption or the space has not been considered Subject to technical changes. Version 17 / 04

 Open the catalogue to page 6

Ceiling diffuser Critical airflow distance in cooling mode Subject to technical changes. Version 17 / 04 / 2015 Vertical penetration depth ymax [m] 471 588 Critical airflow distance xcrit [m] m 3/ h cfm 235 · Air Flow V Vertical penetration depth ymax [m] Critical airflow distance xcrit [m] Research : 1) Nominal dimension 2) Acoustic power LWA 3) Loss of pressure 4) Minimal distance between the diffusers. Vertical penetration depth ymax [m] Example 1 - Data : Height of the space 6m Height of installation 4m (freely suspended) Speed of the airflow at head height (1.8m): 0.2 m/s . Airflow Vo: 1000...

 Open the catalogue to page 7

Ceiling diffuser manual adjustment motorized adjustment Nominal size Subject to technical changes. Version 01 / 01 / 2

 Open the catalogue to page 8

Ceiling diffuser Specification 1 - Description and physical characteristics 1.1 The adjustable VAL diffusers shall consist of a circular duct with three (3) rings which guide the airflow with a manual or motorized adjustment mechanism. 1.2 The adjustment mechanism shall be composed of a deflector, a reduction ring and an adjustable control dial. 2.1 The performance shall be guarantee by using performance curves or simulation software for critical areas. These shall indicate the loss of pressure and the acoustic power generated and shows a cross-section of the critical airflow trajectory in cooling...

 Open the catalogue to page 9

NAD Klima 144, rue Léger, Sherbrooke (Québec), Canada J1L 1L9 T : 819 780-0111 • 1 866 531-1739 F : 819 780-1660 info@nadklima.com NAD Klima Ontario 2840, Argentia Road, Unit 6, Mississauga (Ontario), Canada L5N 8G4 T : 416-860-1067 ontario@nadklima.co

 Open the catalogue to page 10

All NAD Klima catalogues and technical brochures

  1. NAC air curtain

    12 Pages

    En
  2. FDD diffuser

    20 Pages

    En
  3. RRA diffuser

    26 Pages

    En
  4. DAL 358 diffuser

    22 Pages

    En
  5. BD Diffuser

    10 Pages

    En
  6. HDQ Diffuser

    8 Pages

    En
  7. Inducto Diffuser

    8 Pages

    En
  8. VLD-VLV Diffusers

    12 Pages

    En
  9. LDI Diffuser

    16 Pages

    En
  10. WKD 381 Diffuser

    12 Pages

    En
  11. WKD 380 Diffuser

    12 Pages

    En
  12. SAL 35 Diffuser

    22 Pages

    En
  13. DAL 382 Diffuser

    12 Pages

    En
  14. MSA Diffuser

    12 Pages

    En
  15. LDK Diffuser

    16 Pages

    En
  16. DAL 359 Diffuser

    16 Pages

    En
  17. Swirl diffuser DRS

    16 Pages

    En

Archived catalogues