Catalogue excerpts

Industrial Diffusers Model ILV Description, Area of Application and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Method of operation and Aerodynamic Data . . . . . . . . . . . . . . . . . . . . . . . . . . Diagrams - Horizontal stream without ceiling influence and example . . . . . . . . . . - Vertical penetration depth, vertical jet deflection in cooling mode - Vertical stream temperature ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalogue to page 2

Industrial Diffuser Description, Area of Application and Benefits Industrial Air Displacement Diffuser ILV Diffuser ILV was specially developed for industrial applications. This diffuser has many different discharge patterns available and thus can be used in many situations, for example horizontal (cooling) and vertical (heating) jets as well as localized displacement flow are possible. The latter being especially important for areas that are thermally loaded or polluted, because the displacement flow quickly discharges the load. ILV can be deployed directly under the ceiling or in a suspended...

 Open the catalogue to page 3

NAD Klima Industrial Diffuser Diffuser ILV consists of an external perforated galvanized sheet steel shell plate with attached spigots and an internal perforated air control corpus with small diameter, whereby several impermeable diffuser rings are situated between the plate and the corpus. The lower end of the interior air control corpus acts as a rotatable damper, which opens or closes the air control mechanism and thus creates a The damper is situated on a shaft that extrudes on one side from the shell plate. An adjustment mechanism (chain lever or actuator) is fitted on the outer end of the...

 Open the catalogue to page 4

Industrial Diffuser Method of Operation and Aerodynamic Data Method of Operation With the bottom damper closed, air entering the diffuser is diverted and is discharged through the opening in the diffuser shell. The ideal arrangement of the diffuser rings guarantees a consistent flow across the entire height of the diffuser shell. Rotating the bottom damper 90° opens the air control mechanism downwards and thus generates a distinct vertical jet that reached large penetration depths even at high temperatures. The jet is controlled via a chain lever or a motor. Aerodynamic Data Nominal Size Note:...

 Open the catalogue to page 5

Industrial Diffuser Rating Diagrams and example Horizontal stream without ceiling influence ˙ Air ow V [m / h] Specifications : Airflow / diffuser : V = 1700 m3/h Nominal Size : DN 450 Airflow velocity : Vmax = 0.25 m/s Temperature difference : ∆T0 = 10°C Required : 1- Acoustic power level LWA and pressure loss ∆Pt 2- Airflow distance : X 3- Vertical penetration :YMAX 4-Vertical jet deflection : Y 5- Airflow velocity : VMAX 6- Temperature Solution : 1. With an airflow of 1700 m3/h, we read on diagram “ Horizontal stream without ceiling influence” : LWA = 35 dB (A) 3 and ∆Pt = 15 Pa 4 2. And, we...

 Open the catalogue to page 6

NAD Klima Industrial Diffuser Vertical penetration depth in cooling Vertical jet deflection y to bottom [m] Vertical jet deflection y to bottom [m] Vertical jet deflection y to bottom [m] Subject to technical changes. Version 18 / 09 / 2012

 Open the catalogue to page 7

Industrial Diffuser Diagrams Vertical stream temperature ratio ˙ Air ow V [m / h] 6 Airow distance x or x+y [m] respectively Vertical airow distance y [m] Subject to technical changes. Version 18 / 09 / 2012

 Open the catalogue to page 8

Industrial Diffuser Specifications and Codification Specifications 1 - Description and Physical characteristics 1.1 ILV diffuser consist of a circular grid for diffusion, three rings guiding the air flow and a manual or motorized adjusting mechanist. 2.1 The performance of ILV diffuser will be demonstrate on diagrams showing the pressure loss and the sound power level generated and the air flow distance in cooling and heating mode. 1.2 Adjustment mechanism consists of a damper mounted on a horizontal transverse axis and a gear wheel. 1.3 The diffuser, its components and the damper are made of...

 Open the catalogue to page 9

Industrial Diffuser Description, Area of Application and Benefits Aerodynamic Data Variable Air Displacement Diffuser VVA This diffuser was specially developed for industrial applications in which comparatively large amounts of air can be effectively yet draft-free supplied to working areas. The VVA can be adapted to suit many different cases of operation and conditions. Areas of Application - Industrial halls - Commercial space - Thermally loaded workspaces - Polluted workspaces - Rooms with heights from 4 m to 15 m - Volume flows from 1000 m3/h to 10000 m3/h The diffuser consists of a hexagonal...

 Open the catalogue to page 10

Industrial Diffuser Jet setting Specifications and codification Setting the Jet The basic jet settings during cooling are achieved by varying the type and order of the clips. In addition to this, a continuous transition from a horizontal to vertical jet can be achieved by adjusting via the bottom opening. 1. Description and Physical Characteristics The following adjustment variations are available: - Manual adjustment with cord-pull mechanism - Manual adjustment with control cable - Continuously adjustable motor 1.1 The hexagonal diffuser VVA is made of galvanized steel . 1.2 It has horizontal...

 Open the catalogue to page 11

NAD Klima 144, Léger St., Sherbrooke (Québec), Canada J1L 1L9 • T : 819 780-0111 • 1 866 531-1739 • F : 819 780-1660 • info@nadklima.com

 Open the catalogue to page 12

All NAD Klima catalogues and technical brochures

  1. VAL diffuser

    10 Pages

    En
  2. NAC air curtain

    12 Pages

    En
  3. FDD diffuser

    20 Pages

    En
  4. RRA diffuser

    26 Pages

    En
  5. DAL 358 diffuser

    22 Pages

    En
  6. BD Diffuser

    10 Pages

    En
  7. HDQ Diffuser

    8 Pages

    En
  8. Inducto Diffuser

    8 Pages

    En
  9. VLD-VLV Diffusers

    12 Pages

    En
  10. LDI Diffuser

    16 Pages

    En
  11. WKD 381 Diffuser

    12 Pages

    En
  12. WKD 380 Diffuser

    12 Pages

    En
  13. SAL 35 Diffuser

    22 Pages

    En
  14. DAL 382 Diffuser

    12 Pages

    En
  15. MSA Diffuser

    12 Pages

    En
  16. LDK Diffuser

    16 Pages

    En
  17. DAL 359 Diffuser

    16 Pages

    En
  18. Swirl diffuser DRS

    16 Pages

    En

Archived catalogues