MAC 2000 PROFILESPECIFICATIONS

Installation Details Photometrics (Standard) Ordering information
•Mounting points: 8 pairs of 1/4-turnlocks, offset 45°•Orientation: any •Light output: 19,000 lumens •Illuminance (lux or fc): 713,500 cd/distance2 (m or ft)•Field angle at full spot(30 mm image on gobo wheel 1): 10°•Field angle at full flood (30 mm image on gobo wheel 1): 28°•Measurement conditions: 230 V, 50 Hz; 13°rustic beam•Measurement source: Osram HMI 1200 W/S•Ballast - magnetic •MAC 2000 Home profile II in 1-unit flight case: P/N 90205610•2 MAC 2000 Profile IIs in a 2-unit flight case: P/N 90205600•MAC 2000 Profile II E in 1-unit flight case:P/N 90205810•2 MAC 2000 Profile II Es in a 2-unit flight case: P/N 90205800•White MAC 2000 Profile II in a 1-unit flight case: P/N 90205620•White MAC 2000 Profile II E in a 1-unit flight case: P/N 90205820 Source
Lamp suppliers: 1200 W short arc discharge •Base: Double-ended SFc 10-4 with key •Approved models: Osram HMI 1200 W/S •Control: automatic and remote on/off Gobos
•Outside diameter: 37.5 +0/-0.3 mm (1.48 +0/-0.01 in.)•Image diameter: 30 mm (1.18 in.)•Thickness: 1.1 mm in static slots,up to 7 mm in rotating slots•Material: high-temperature Borofloat or better glass•Coating: dichroic or enhanced aluminum Control & Programming Included items
•Protocol: USITT DMX-512 •Control channels: 20 or 24•Receiver: Opto-isolated RS-485 •Data I/O: locking 3-pin & 5-pin XLR, pin 1 shield, pin 2 cold (-), pin 3 hot (+)•Setting and addressing: LED control panel, remote w/ MP-2 uploader•Pan/tilt resolution: 8- or 16-bit •Gobo indexing: 8- or 16-bit •Movement control: tracking and vector •Architectural software installation: serial upload (MUF) •2 x Omega bracket, 1/4-turn•User manual •XLR cable •Fuses Description
The MAC 2000 Profile II is a 1200 W movinghead building spotlight that provides CMY color mixing, continuous color correction, a color/gobo wheel with 4 color filters and 3 static gobos, 10 indexable gobos on 2wheels, rotating 3-facet prism, rotatingbeam shaper, variable frost, combined dimmer/shutter, iris, focus, zoom, 540°of pan, and 267°of tilt.The MAC 2000 Profile II has an auto-sensing,auto-ranging, Switch Mode Power Supply(SMPS), and is available in both magnetic and electronic ballast versions (desiginated as 'E'). Electromechanical effects
•Cyan: 0 - 100% •Magenta: 0 - 100% •Yellow: 0 - 100% •Color correction: 0 - 178 mireds •Color/gobo wheel: 4 color filters and 3 gobos•Gobo wheel 1: 5 rotating slots •Gobo wheel 2: 5 rotating slots •Effect wheel: rotating 3-facet prism, rotating beam shaper, variable frost•Dimmer/shutter: full range dimming and variable speed flash•Focus: 2 m (6.5 ft.) - infinity •Zoom: 10°- 28°•Iris: 15- 100% open•Pan: 540° •Tilt: 267° Physical
•Length: 408 mm (16.0 in)•Width: 490 mm (19.3 in) •Height: 743 mm (29.3 in) Weight:
•Profile II (magnetic ballast): 45 kg (99 lbs)•Profile II E (electronic ballast): 38 kg (84lbs) Accessories Thermal
•MP-2 Uploader: P/N 90758420•G-clamp: P/N 91602003•Half-coupler clamp: P/N 91602005 •Wide angle kit: P/N 91610020 •"The Wife" DMX Tester: P/N 91611038 •Maximum ambient temperature (Ta): 40°C (104°F)•Maximum surface temperature: 140°C (284°F)•Total heat dissipation: ca. 5120 Btu/hr Design standards
•EU EMC: EN 50 081-1, EN 50 082-1•EU safety: EN 60598-1, EN 60598-2-17•Canadian safety: CSA C22.2 No. 166 •US safety: ANSI/UL 157 Construction
•Housing:UV-resistant fiber-reinforcedcomposite•Colors: black, white•Protection factor: IP 20 Electrical
•AC input: 3 m trailing cable w/o cord cap •Power supply: Auto-sensing, auto ranging, switch-mode power supply•Operating ranges (electronic ballast):100-130/200-260 V, 50/60 Hz•Operating ranges (magnetic ballast):200- 260 V, 50/60 Hz•Main fuses (x 2 - when local AC supply is 200 - 250 V): 15 A•Main fuses (x 2 - when local AC supply is 100 - 120 V): T 20 A•Fuse F101 (on printed circuit board): T 6.3 A•Fuse F102 (on PCB): T 10 A •Fuse F103 (on PCB): T 3.15 A•Fuse F104 (on PCB): T 3.15 A Maximum power and current Magnetic ballastElectronic ballast
VoltHzWattAmppower VoltHzWattAmppower factorfactor100 V 50 Hz1590 W19.8 APF 0.8 100 V 60 Hz1560 W19.3 APF 0.8 120 V 50 Hz1560 W16.8 APF 0.8 120 V 60 Hz1540 W16.3 APF 0.8208 V 50 Hz1520 W9.3 APF 0.8208 V 50 Hz1470 W10.5 APF 0.7208 V 60 Hz1410 W7.5 APF 0.9208 V 60 Hz1470 W10.3 APF 0.7 230 V 50 Hz1470 W7.6 APF 0.8230 V 50 Hz1480 W9.6 APF 0.7 230 V 60 Hz1450 W7.0 APF 0.9230 V 60 Hz1470 W9.4 APF 0.7 250 V 50 Hz1480 W7.4 APF 0.8250 V 50 Hz1480 W8.6 APF 0.7 230 V 50 Hz1470 W7.6 APF 0.8250 V 60 Hz1480 W8.5 APF 0.7
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
 
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
pdf-page pdf ae En 2009-11-48-24