museum collection
28Pages

{{requestButtons}}

Catalog excerpts

museum collection - 2

Litelab’s Museum Collection was designed with the professional in mind. Throughout the Museum Collection, Litelab has incorporated features that allow for all focus angles to be lockable by touch or by tool. Lamps are replaceable without changing focus. Accessories are made to highgrade professional standards and sized in such a way that professionals focusing exhibits can create almost any effect using a minimal number of components. In addition, each fixture is paired as an object light and a wall wash so that either choice is available for any lamp selection. Finally, glare control is...

Open the catalog to page 2
museum collection - 3

Front Cover and Inside Spread: The Museum of Modern Art | New York, NY Architect: Yoshio Taniguchi | Lighting Design: George Sexton Associates

Open the catalog to page 3
museum collection - 4

Object Wallwash Object Wallwash Object Wallwash Q Object Wallwash Object Wallwash Object Wallwash Object Wallwash Object Wallwash Object Wallwash

Open the catalog to page 4
museum collection - 5

National Gallery of Australia | Canberra, Australia The Museum of Modern Art | New York, NY Louisiana Museum | Copenhagen, Denmark From Australia to Denmark and New York, our portfolio spans the globe. For more than 35 years, Litelab has serviced the international markets. With factories in the United States, China, and Europe, Litelab is uniquely equipped to manufacture and service clients on a local basis. We manufacture in accordance with local codes so that conformity is never an issue. We are proud to have worked with many of the world’s preeminent architects and designers and in many...

Open the catalog to page 5
museum collection - 6

6 Museum Collection Lighting Instruments Institute of Contemporary Art | Boston, MA Architect: Diller Scofidio + Renfro | Lighting Design: ARUP

Open the catalog to page 6
museum collection - 7

Halogen Fixtures Litelab offers a full range of wattages and sources for halogen fixtures, still the gold standard for bringing out the best in art objects. Compared to newer lighting technologies, halogen – we believe – is still the premium for crisp, accurate color portrayal of valuable art objects. For those clients who need simply the best color rendering source, halogen remains the one to beat.

Open the catalog to page 7
museum collection - 8

Lighting Specs: 12V Halogen 75W Maximum* Lighting Specs: 12V Halogen 75W Maximum* Lighting Specs: 2.0”[51] 120V/230V Halogen 75W Maximum 4.5”[115] 8.0”[203] Lighting Specs: 120V/230V Halogen 75W Maximum 8 Museum Collection Lighting Instruments * Fixture shown accepts wattages up to 75W. Over 75W please consult www.litelab.com.

Open the catalog to page 8
museum collection - 9

Lighting Specs: 12V Halogen 75W Maximum* 120mm Lighting Specs: 8.0”[203] 12V Halogen 75W Maximum* Lighting Specs: 120V/230V Halogen 2.0”[51] 250W Maximum Lighting Specs: 120V/230V Halogen 2.0”[51] 250W Maximum For additional information, consult www.litelab.com and review Luminaires|Surface – Museum Collection.

Open the catalog to page 9
museum collection - 10

Lighting Specs: 120/230V Halogen 500W Maximum Lighting Specs: Transformer within yoke. 120/230V Halogen 500W Maximum Transformer within yoke. Transformer within yoke. Transformer within yoke. Lighting Specs: 12V Halogen 8.75”[222] 230W Maximum Transformer within yoke. Transformer within yoke. Lighting Specs: Transformer within 12V Halogen yoke. 8.75”[222] 230W Maximum Transformer within yoke. 10 Museum Collection Lighting Instruments C

Open the catalog to page 10
museum collection - 11

Grand Rapids Museum of Art | Grand Rapids, MI Photo: Scott McDonald/Hedrich Blessing | Architect: wHY Architecture | Lighting Design: Isometrix

Open the catalog to page 11
museum collection - 12

12 12 Museum Collection Lighting Instruments Museum Collection Lighting Instruments Salvador Dali Museum | St. Petersburg, FL Photo: Moris Moreno | Architect: HOK | Lighting Design: George Sexton Associates

Open the catalog to page 12
museum collection - 13

Metal Halide Fixtures In response to our clients who want longer lamp life and less power consumption for the power light level produced – Litelab provides a viable option. For years, metal halide was considered a poor source for museums because of its high UV output and low-color rendering index. Today, designers can consider this a creative application and specify it with confidence. Recent advancements in color resolution, combined with Litelab’s unique color correction lensing system and a longer lamp life, now makes this source a strong contender. Litelab is proud to offer a complete...

Open the catalog to page 13
museum collection - 14

M U S E U M CO L L E C T I O N METAL HALIDE MR16 Object M15MR16M Lighting Specs: 120/230V Metal Halide 39W Maximum Lighting Specs: 120/230V Metal Halide 39W Maximum Lighting Specs: 2.0”[51] 120V/230V Metal Halide 70W Maximum* Lighting Specs: 120V/230V Metal Halide 70W Maximum* 14 Museum Collection Lighting Instruments * Fixture shown accepts wattages up to 39W. Over 39W please consult www.litelab.com.

Open the catalog to page 14
museum collection - 15

METAL HALIDE T4MH Object M27T4MH Lighting Specs: T4 Metal Halide [G8.5] 70W Maximum* Lose the ballast – specify the 9M Fitter. 2.0”[51] Litelab’s new 9M fitter integrates the metal halide ballast components into a compact horizontal bar that neatly plugs into BusRun Busway® – eliminating the 2.38”[60] unsightly ballast box and providing clean, linear lines of bus and fixtures. 4.69”[119] Lighting Specs: T4 Metal Halide [G8.5] 70W Maximum* • Metal halide ballast 9M by Litelab for use with 20 and 39 watt; MR16, T4, T6, Par 20 and Par 30 CMH lamps. • Available in 120V and 230V. • For use with...

Open the catalog to page 15
museum collection - 16

M U S E U M CO L L E C T I O N METAL HALIDE R111 Object M19R111 Lighting Specs: 120/230V Metal Halide 70W Maximum* Lighting Specs: 120/230V Metal Halide 70W Maximum* Lighting Specs: 2.0”[51] 120V/230V Metal Halide 150W Maximum Lighting Specs: 120V/230V Metal Halide 150W Maximum 8.0”[203] 16 Museum Collection Lighting Instruments * Fixture shown accepts wattages up to 39W. Over 39W please consult www.litelab.com.

Open the catalog to page 16
museum collection - 17

METAL HALIDE T6MH Object M13T6MH Lighting Specs: 120/230V Metal Halide 150W Maximum Transformer within yoke. 13.38”[340 ] Lighting Specs: Transformer within yoke. 120/230V Metal Halide 150W Maximum Transformer within yoke. Transformer within yoke. Relamping normal lighting fixtures can change the focus to one degree or another – with the Museum Collection it does not. Both the horizontal and the vertical focuses are lockable and the lamp can be changed without ever touching the lock. When an accessory cartridge is involved, it too can be removed without changing the focus or the...

Open the catalog to page 17

All LITELAB Corp. catalogs and technical brochures

  1. busrun-busway

    36 Pages

  2. busport

    20 Pages

  3. fluobus

    12 Pages