Venduct® tile & slate vents
26Pages

{{requestButtons}}

Catalog excerpts

Venduct® tile & slate vents - 1

Venduct® tile & slate vents KLBER Professional roofing accessories A f Ԡw

Open the catalog to page 1
Venduct® tile & slate vents - 3

Contents KLOBER Overview of Klober Page 2 Contact dtails & product range Page 3 Introduction to Venduct® Pages 4-5 The Ventilation Process Pages 6-7 Uni-line® Tile Vent Page 8 Universal Tile Vent Page 9 Profile-Line® Tile Vent Page 10-11 Clay Plain Tile Vent Page 12 Uni-Plain Tile Vent Page 13 Small Slate Vent Page 14 10K Slate Vent Page 15 Uni-Line Slate Vent Page 16 Mini Uni-Line Slate Vent Page 17 Large Slate Vent Page 18 Solar Outlet Page 19 Soil/Mechanical Adaptors, Flexipipes Page 20 Pipe Sealing collar Page 21 Permo®TR tape Page 22 Easy-Form® tape Page 23 1

Open the catalog to page 3
Venduct® tile & slate vents - 4

KLOBER Overview of Klober History Klober was founded in i960 in Schwelm, Germany. The philosophy of the company was to manufacture ventilation pipes on an industrial scale which could be installed on any roof - no matter what the pitch. During the seventies, the product range grew to include safety and support products as well as walkway systems and roof windows. By the start of the 1990's Klober entered the market with vapour permeable membranes which strongly influenced the way roofs were constructed. The development of a ridge and hip solution also changed the installation methods within...

Open the catalog to page 4
Venduct® tile & slate vents - 5

Contact dtails & product range KLBER You can contact us by: Phone Sales: Technical: Switchboard: Email General: Technical: 0800 783 3216 +44 (0)1509 500 675 +44 (0)1509 500 660 J info@klober.co.uk technical@klober.co.uk Website For information on Klober products, how to find your nearest stockist, literature downloads, training days, useful industry links, regulations and Klober's product certifications visit: www.klober.co.uk Area account manager See map opposite 07764 907 138 07764 907138 07702 952061 Fax Sales: General: +44 (0)1509 505 535 +44 (0)1509 600 061 07702 952052 Post Klober...

Open the catalog to page 5
Venduct® tile & slate vents - 6

KI0BER Introduction to Venduct® Ventilation for cold and warm pitched roofs Whenever non-breather underlays are used on pitched roofs, it is essential to provide cross ventilation of the roof voids in order to avoid condensation. For some more complex roof shapes and mono-pitched roofs, tile ventilators may be needed to ensure there are no stagnant air pockets in any part of the roof. Klober provides a wide range of ventilation options to enable those involved in the roofing to select the most appropriate solution for providing ventilation for a particular design. Klober's strength lies in...

Open the catalog to page 6
Venduct® tile & slate vents - 7

Introduction to Venduct® KLOBER Klober offer a wide range of flexipipes and adaptors in order that its tile vent range can be used in conjunction with mechanical/soil extraction. Klober offers a range of high-quality, high performing vents which, when used in conjunction with its adhesive tapes, help reduce heat loss through the roof while providing roof space ventilation. Klober is happy to offer advice on how best to combine and incorporate its products to ensure energy loss through the roof is kept to a minimum. Flexipipes & mechanical adaptors These provide a quick and simple connection...

Open the catalog to page 7
Venduct® tile & slate vents - 8

KI0BER The Ventilation Process Condensation - a rising problem Condensation is a symptom of modern living and of today's proccupation with saving energy by minimising heat loss. The increased presence of central heating, showers and modern domestic appliances produces greater amounts of water vapour in the home. An unvented tumble drier alone can emit as much as 7.5 litres per day. Matters are made worse by the fact that these moisture-producing activities are often concen-trated at certain times of the day, followed by long periods when the house is either unoccupied or unheated. In...

Open the catalog to page 8
Venduct® tile & slate vents - 9

The Ventilation Process KLBER B Lean-to or mono-pitch roof 15° pitch and above 10mm continuous opening at eaves, with additional high level ventilation of 5mm. Below 15°, the opening at the eaves should be increased to 25mm. Solution There are two solutions to prevent excessive condensation forming in a roof void, one is to ventilate in the traditional way and the other is to use an air open or vapour permeable underlay that allows the roof structure to breathe. Klober can offer both, providing a wide range of eaves ventilation systems, slate ventilators and tile ventilators along with a...

Open the catalog to page 9
Venduct® tile & slate vents - 10

KI0BER Uni-line® Tile Vent Product features & benefits In-line design Օ Choice of four colours Fully wind tunnel tested Օ Built in downpipe allows direct ventilation to roof space No mechanical adaptor required Area of application Suitable for: Օ Most popular interlocking and plain tile roofs with a pitch over 20° Roof space ventilation or soil ventilation and mechanical extraction Օ High or low level roof ventilation Material Soft and rigid UPVC Colours Antique red Brown Slate grey Terracotta Dimensions 455 mm long x 440 mm wide x 33 mm deep (excluding downpipe) Weight (per carton)...

Open the catalog to page 10
Venduct® tile & slate vents - 11

Universel Tile Vent KLBER Product features & benefits ԕ Low profile design Choice of four colours Օ Fully wind tunnel tested Built in downpipe allows direct ventilation to roof space Օ Adaptor available for soil ventilation or mechanical extraction Adaptor available for 125 mm diameter ducting Area of application Suitable for: Օ Most popular interlocking and plain tile roofs with a pitch over 17.5° Roof space ventilation or for soil ventilation or mechanical extraction when used with the soil/mechanical adaptor Օ High or low level roof ventilation Material Soft and rigid UPVC Colours...

Open the catalog to page 11
Venduct® tile & slate vents - 12

KI0BER Profile-Line® Tile Vent Product features & benefits In-line design - virtually invisible from the ground Օ Universally designed 6 profiles Օ Choice of four colours Fully wind tunnel tested Օ Built in downpipe allows direct ventilation to roof space Adaptor available for soil ventilation or mechanical extraction Օ Robust construction Area of application Suitable for: High and low level ventilation Օ Mechanical extraction when used with the soil/mechanical adaptor Roof pitches over 17.5° (Double Roman, Double Pantile & Limarech) & 20° (15 x 9, Flat Vent & Single Pantile) Material...

Open the catalog to page 12