MultiBase G63 outdoor
5Pages

{{requestButtons}}

Catalog excerpts

MultiBase G63 outdoor - 1

PRODUCT DATA Width dim. Function Approach Outdoor installation All space requirements are minimum finished dimensions. Tolerances for space requirements + 3 . 0 Dimensions in cm. EB (single platform) = 3 vehicles DB (double platform) = 6 vehicles Load per park. space Load plan Page 4 Technical data Standard passenger cars: Limousine, station wagon, SUV, van according to clearance and maximal surface load. To be performed by the customer Description car height lower level 150 car height middle level 160 car height lower level car height middle level 520 for vehicle up to 5.00 m = 16’4’’ long (540 for vehicle up to 5.20 m 17’ long) 11 Standard Special 190 cm 4 190 cm see page 3 see page 3 wheel load Cutting through width weight Electrical installation car height middle level car height lower level 170 To the extent that the conditions of the construction do not restrict the height, the car height on the upper parking slots is not restricted. 1 2 3 4 5 6 7 Standard type Special system: maximum load (only EB) for extra charge. To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202. Car width for platform width 230 cm. If wider platforms are used it is also possible to park wider cars. For dividing walls: cutting through 10 x 10 cm. Potential equalization from foundation grounding connection to system (provided by the customer). Slope with drainage channel and sump. With direct connection to the sewerage system. Three-sided barrier compliant to DIN EN ISO 13857. In compliance with DIN EN 14010, 10 cm wide yellow-black markings compliant to ISO 3864 must be applied by the customer to the edge of the pit in the entry area to mark the danger zone (see „load plan“ page 3). At the transition section between pit floor and walls no hollow mouldings/coves are possible. If hollow mouldings/coves are required, the systems must be designed smaller or the pits accordingly wider. For convenient use of your parking space and due to the fact that the cars keep becoming longer we recommend a pit length of 540 cm. MultiBase G63 Outdoor installation | Code number 586.50.230-00

Open the catalog to page 1
MultiBase G63 outdoor - 2

Width dim. Function Approach Load per park. space Load plan Page 4 Electrical installation Technical data To be performed by the customer Description MultiBase G63 Outdoor installation | Code number 586.50.230-003 | Version 12.2016 Width dimensions Single and Double Platform (EB + DB) – Example EB Carriageway in accordance with local regulations For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm for single platforms and 500 for double platforms. Problems may occur if smaller platform widths are used (depending on car type,...

Open the catalog to page 2
MultiBase G63 outdoor - 3

Width dim. Function Approach Load per park. space Load plan Page 4 Electrical installation Technical data MultiBase G63 Outdoor installation | Code number 586.50.230-003 | Version 12.2016 Load per parking space For countries where snow loads are a crucial factor wheel load parking spaces wheel load upper parking space upper parking space middle parking space middle parking space lower parking space lower parking space MultiBase G63 2,5 to. (only EB) – for extra charge MultiBase G63 2,5 to. (only EB) – for extra charge parking spaces wheel load parking spaces wheel load upper parking space...

Open the catalog to page 3
MultiBase G63 outdoor - 4

MultiBase G63 Outdoor installation | Code number 586.50.230-003 | Version 12.2016 Electrical installation Installation diagram Function Approach Technical data Stand for operating device Foundation earth connector Supply line 5 x 2.5 mm2 (3 PH + N + PE) with marked wire and protective conductor Equipotential bonding in accordance with DIN EN 60204 from foundation earth connector to the system Electrical data (included in delivery of KLAUS Multiparking) Main fuse: 3 x fuse 20 A (slow) or circuit breaker 3 x 20 A (trigger characteristic K or C) Electrical installation Electricity meter Load...

Open the catalog to page 4
MultiBase G63 outdoor - 5

Width dim. Function Approach Load per park. space Load plan Page 4 Electrical installation Technical data To be performed by the customer Description MultiBase G63 Outdoor installation | Code number 586.50.230-003 | Version 12.2016 To be performed by the customer Safety fences Constraints according to DIN EN ISO 13857 must be put in place on three sides (all except the entrance side), unless buildings border the pit. Numbering of parking spaces Consecutive numbering of parking spaces. Building services Any required lighting, ventilation, fire extinguishing and fire alarm systems as well as...

Open the catalog to page 5