Catalogue Jøtul Cast Iron Stoves and Fireplaces Part 2
www.jotul.com
print switch display
Page / 13
Contact the
Manufacturer
Where to buy
this product ?
Jøtul - 20656, 25864, 19838
/ 13
See other catalogues for Jøtul
Text version of the page
1 ~J yt V- w I I
J0tul F 602
Finish Options: Matt Black paint
(Standard) Matt Black paint Blue-black enamel (Cleanburn with glass contemporary door)
Heat Output: Min 1 kW,
Rated 6 kW Max 8.5 kW
Maximum Log Length: 400 mm
Flue Outlet: Top / Rear
Flue Size: 125 mm / 5" dia.
(adapter required)
Accessories:
• Glass Door (Black paint) (320073)
540
302
o
? o
u5
I ,280 , I
Catalogue Number:
• 320036 Cast iron door - standard (Black paint)
• 320086 Glass door - cleanburn (Blue-black enamel)
• 320089 Glass door - cleanburn (Black paint)
SI
J0tul F 118 CB
Finish Options: Matt Black paint
Heat Output: Min 4.0 kW,
Rated 7.0 kW Max 11.0 kW Maximum Log Length: 600 mm Flue Outlet: Top / Rear / Both sides
Flue Size: 150 mm / 6" dia.
(adapter included)
Accessories:
• Rear Heat Shield (320098)
• Side Heat Shield (320099)
o 00
It
734
841
Catalogue Number: • 320096 (Black paint)
□ c
J0tul F 100
Finish Options:
Matt Black paint Blue-black enamel Pewter enamel
526
TTT
ra— -<№- ~ko|
I
fil
Heat Output:
Min 2.7 kW,
Rated 5.5 kW Max 7.5 kW Maximum Log Length: 400 mm Flue Outlet: Top / Rear
Flue Size: 125 mm / 5" dia.
Accessories:
• Multi-fuel Kit (350718)
• Long legs - Black paint (350735), Blue-black enamel (350736) or Pewter enamel (10192546)
r-~ A in
. 336 .
445
528
Catalogue Number:
•35°738 Woodburner(Blackpaint)
• 35°739 Wood burner(Blue-blackenamel)
• 35°927 Wood burner (Pewter enamel) •350710 Multi Fuel (Black paint)
• 350711 Multi Fuel (Blue-blackenamel) •350926 MultiFuel(Pewterenamel)
• 35°794 Multi Fuel (Black paint) Plain Door
General note for all stoves manufacturer and design fireplaces
1. Please note that the minimum heat output is achieved with the cleanburn system (where applicable) performing ( See Page 49)
2. Please note that the rated output is based on laboratory achieved results when tested under DIN, EN or CE approval conditions
3. Figures given for heat output are based on refuelling with wood every two hours. Outputs vary depending on the quality of the fuel used and refuelling periods.