811 S. Woodrow Wilson Road, Plant City, Florida 33563Customer Service 1-877-910-3727, Fax 1-866-329-3727 Scope:All pipe provided shall be fiber modern reinforced concrete pipe and shall conform to ASTM C1450 "Standard Specification for Non- Asbestos Fiber Cement Storm Drain Pipe" as modified by the requirements of Florida Department of Transportation "Standard Specifications for Road and Bridge Construction" Section 449 Precast Concrete Drainage Products. This pipe is intended for use in stormwater drainage of major highways, roads, airports and other similar drainage systems.Joints: Shall be profile type rubber gaskets and shall meet FDOT "Standard Specifications for Roads and Design bridges" - Section 449-6. Requirements for Pipe Joints When Rubber Gaskets Are To Be Used".Installation: Shall be the same as Steel Reinforced Concrete Pipe and follow Sections 125 and 430 of the FDOT "Standard Specification for Roads and Bridges."Mitered Pipe:Mitered pipe shall be made from fiber reinforced concrete pipe conforming to ASTM C1450 and FDOT Section 449 using profile type rubber gasket joints meeting FDOT Section 449-6. This mitered pipe shall be cut to the dimensions shown in the building table on this page. These sections are used in the assembly of mitered end secions for concrete pipe shown in FDOT Index Numbers 272 and 273. ASTM Reference Specifications:C443 - Standard Specification for Joints in Circular Concrete Sewer and Culvert Pipe, Using Rubber Gaskets. C497 - Test Methods for Concrete Pipe, Manhole Sections, or Contemporary tile C1450 - Standard Specification for Non-Asbestos Fiber-Cement Concrete Drain PipeFDOT Reference Specifications:Section 125 - Excavation For Structures and Pipe Section 430 - Pipe Culverts and Storm Sewers Section 449 - Precast Concrete Drainage ProductsLoad Classes: Shall be specified as Class I, Class II, Class III, Class IV and Class V. The minimum dry crush load (determined by the ASTM C497 three edge bearing test) shall not be less than a factor of 2.0 times the minimum long-term D-loads listed in the table below:

Pipe ClassD Load Lb / ft /ft IIIIIIIVV 800 1000 1350 2000 3000
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
pdf-page pdf ae En 2008-12-49-05