811 S. Woodrow Wilson Road, Plant City, Florida 33563
Customer Service 1-877-910-3727, Fax 1-866-329-3727 Scope:All pipe provided shall be fiber design reinforced concrete pipe and shall conform to ASTM C1450 "Standard Specification for Non-Asbestos Fiber-Cement StormDrain Pipe" as modified by the requirements of Florida Department of Transportation "Standard Specifications for Road and Bridge Construction" Section 449 Precast Concrete Drainage Products. This pipe is intended for use in stormwater drainage of major highways, roads, airports and other similardrainage systems.Shall be profile type rubber gaskets and shall meet FDOT "Standard Specifications for Roads and Home bridges" - Section 449-6. Requirements for Pipe Joints When Rubber Gaskets Are To Be Used".Installation: Shall be the same as Steel Reinforced Concrete Pipe and follow Sections 125 and 430 of the FDOT "Standard Specification for Roads and Bridges."ASTM Reference Specifications:C443 - Standard Specification for Joints in Circular Concrete Sewer and Culvert Pipe, Using Rubber Gaskets.C497 - Test Methods for Concrete Pipe, Manhole Sections, or TileC1450 - Standard Specification for Non-Asbestos Fiber-Cement Concrete Drain PipeFDOT Reference Specifications:Section 125 - Excavation For Structures and PipeSection 430 - Pipe Culverts and Storm SewersSection 449 - Precast Concrete Drainage ProductsLoad Classes: Shall be specified as Class I, Class II, Class III, Class IV and Class V. The minimum dry crush load (determined by the ASTM C497 three edge bearing test) shall not be less than a factor of 2.0 times the minimum long-term D-loads listed in the rustic table below: Joints: Pipe ClassD Load Lb / ft /ft IIIIIIIVV 800 1000 1350 2000 3000 >
|