TD 68 Thermally Improved Commercial Door & Framing System Tested to and compliant with PAS 24 in a UKAS approved test rig. SPECIFICATION MANUAL All about Security . . . All about Thermal Efficiency . . . All about Performance . . . Issue 15 v 15.05.26

 Open the catalogue to page 1

Contents Design Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Inertia Data and Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 U-Value Calculations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 PAS 23...

 Open the catalogue to page 3

Design Concept Jack Thermally Improved Ground Floor Treatments A door designed specifically to meet the demands of today and tomorrows commercial market The Jack Thermal Door was designed with four key objectives in mind: architectural hardware is key to this improvement. To meet the standard required of the industry for thermal performance, durability and sustainability. Versatility The system will enable the architect or specifier to confidently design for new build or retro fit on refurbishment projects. Security Increasing Security is demanded and using PAS24 and PAS23 one can measure improvement....

 Open the catalogue to page 5

Performance Data TD 68mm Thermally Broken Commercial and Entrance Door and Framing door plus a 1.5 KN load parallel to the plane of the door. The purpose of the parallel load at the locking pint is to exert a force trying to separate the lock stile from the keep whilst also exerting the perpendicular load on the same position, thus simulating someone using a Jemmy or Crow Bar on the locking system. This test is also applied at other points on the door including the bottom pivot and top arm positions as these could be prone to the same level of attack. Composition and Manufacture The Aluminum profiles...

 Open the catalogue to page 7

Performance Data For centre pivot doors suitable strength closures must be fitted according to the width and height of the door Maximum door height has been tested to 2300 mm and width 1250 mm. The use of heavy duty Exidoor bottom pivots are recommended. BS6262 Code of practice for glazing buildings. BS EN 755-9 Aluminium and aluminium alloys. Profile tolerances on dimension and shape. © BS 3987 Specification for anodic coatings and BS EN 12206-1:2004 for powder coated organic coating for application to aluminium alloy for external architectural applications.

 Open the catalogue to page 8

ALUMINIUM SYSTEMS Inertia Data FROM EXTREME BOTTOM AXIS ORIENTATION. SLIM LOCK STILE STANDARD LOCK MULTI POINT LOCK ANTI FINGER TRAP ANTI FINGER TRAP PANIC STILE BOTTOM RAIL

 Open the catalogue to page 9

Inertia Data ALUMINIUM SYSTEMS ANTI FINGER TRAP POCKET PLATE POCKET CHANNEL POCKET PLATE SLIM DOOR JAMB AUTO HEADER FROM EXTREME BOTTOM AXIS ORIENTATION.

 Open the catalogue to page 10

ALUMINIUM SYSTEMS Inertia Data FROM EXTREME BOTTOM AXIS ORIENTATION.

 Open the catalogue to page 11

Sample Style: Fully glazed residential door Blue line Illustrates opening light length Upper Panel dim's and properties: Thickness of upper panel, dg/p1 Panel type: Glazing panel Thermal Transmittance of panel - 3DP Door air leakage heat loss, W/(m K) Simulator Name: BFRC Certified

 Open the catalogue to page 13

Report Number: Sample Style: Report Date: Project Details: Fully glazed residential door with mid rail Report Issue Status: Jack Aluminium - Anti Finger Polyamide System THIS SPREADSHEET IS THE PROPERTY OF THE BFRC AND CAN ONLY BE USED IN CONJUNCTION WITH A BFRC LICENCE APPLICATION Input Values: Yellow input, green intermediary, blue finals X' D is no.of decimal places to enter P 2 1 Blue line illustrates opening light length (air leakage) Total door height 0DP Total door width 0DP Frame dimensions (All frame dimensions to nearest 0.5mm) F3 top hinge (LH) jamb (moving sash) F4 top hinge (LH) jamb...

 Open the catalogue to page 14

ALUMINIUM SYSTEMS U-Value Calculations Butyl (isobutene), solid / hot mell 0.240 EPDM (ethylene propylene diene monomer] 0.250 Mohair (polyester) sweep 0.140 Polyamk) 6.6 with 26% glasstibre 0.300 Soda lime glass 1.000 G:\Simulation PA Door and Window\Jack Commercial Door\SGG Panitherm Total + 1.219 [new header bar]\antifinger -1.219.flx

 Open the catalogue to page 15

U-Value Calculations ALUMINIUM SYSTEMS EPDM (ethylene propylene diene monomer) 0.250 Mohair (polyester) sweep 0.140 Polyamld 6.6 with 25% glassfibre 0.300 G:\Simulation PA Door and WindowvJack Commercial DoorVSGG Panitherm Total + 1.219 [new header bar]\antifinger.flx

 Open the catalogue to page 16

ALUMINIUM SYSTEMS U-Value Calculations Butyl (isobulene), solid ■ hot melt 0.240 I EPDM (ethylene propylene diene monomer) 0.250 I Mohair (polyester) sweep 0.140 H Polyamid 6-6 with 25% glasstibre 0.300 Slightly ventilated air cavity Eps=0.9/0.9 Soda lime glass 1.000 G:\Simulation PA Door and WindowUack Commercial DoonSGG Panitherm Total + 1.219 [new header bar] no foam\bottom rail -1.219.flx

 Open the catalogue to page 17

Value Calculations ALUMINIUM SYSTEMS _ EPDM (ethylene propylene diene monomer) 0.250 I Mohair (polyester) sweep 0.140 I Polyamid 6.6 with 25% glasstibre 0,300 Slightly ventilated air cavily Eps=0.9/0,9 G:\Simulation PA Door and WindowNJack Commercial Door\SGG Panitherm Total + 1.219 [new header bar] no foam\bottom rail - panel.flx

 Open the catalogue to page 18

ALUMINIUM SYSTEMS U-Value Calculations Material [W/(rrvK)] I Butyl (isobutene). solid / hot melt 0.240 I EPDM (ethylene propylene diene monomer) 0.211 H Mohair (po^ester) sweep 0.140 ■ Polyamid 6.6 with 25% glassfibre 0.300 _ Soda lime glass 1.000 G:\Simulation PA Door and WindowUack Commercial Door\SGG Panitherm Total + 1.219\hingestile -1.219.fix

 Open the catalogue to page 19

U-Value Calculations ALUMINIUM SYSTEMS Material [W/(m-K>] EPDM (ethylene propylene diene monomer) 0.2T 1 Mohair (polyester) sweep 0,140 Polyamid 6.6 with 25% olassfibre 0.300 G:\Simulation PA Door and Window\Jack Commercial Door\SGG Panitherm Total + 1.219\hingestile - panel.flx

 Open the catalogue to page 20

ALUMINIUM SYSTEMS U-Value Calculations Butyl (isobutene). solid / hot melt 0.240 EPDM (ethylene propylene dlene monomer) 0.211 Polyamid 6.6 with 25% glassfibre 0,300 Soda lime glass 1.000 G:\Simulation PA Door and WindouAJack Commercial DoorVSGG Panitherm Total + 1.219 + Foam\mid rail -1.219.flx