| | | • Aluminium track. • The track houses the wires that are shielded by rigid extruded isolating material The isolating material has very high dielectric resistance. • The 3-phase wires with a common ground provide 3 separate circuits that allow the use of 3 distinct building switches. Powering the track to the one phase network, the maximum load is 16° (3500 VA), divided up in 3 circuits. • Connection to the 3-phase power network allows the system to have a total load of 16° (10500 VA) divided into 3 circuits (3x3500 VA). • The lateral position of the grounding element makes the track structure asymmetrical. Therefore, the connecting joints must be chosen by keeping this in mind. | | • Also available: versions with T16 fluorescent modules for uplight emission. These modules have electronic and dimmable DALI control gear. The electronic version features multi-power ballasts that allow users to select the power of the fluorescent tube. • The technical characteristics of the fitting comply with EN60598-1 standard. • Linear mass: 1,5 kg/m • IP20 • IMQ-ENEC approval • Class of Insulation I | | |
| | | For installations other than the ones specified, calculate the hanging structure bearing in mind that the weight of the track is 1,5 kg (approx 1,5daN) per linear metre and that each suspension element supports the following loads with a safety rating of 5: 10 kg (approx. 10daN) for 9179-9180-9181; 20 kg (approx. 20daN) for 9182. Track installation for Le Perroquet fittings (art. 4867-4868-4869) is recommended with rigid systems (art. 9179-9180-9181-9182). | | |