Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Electronic Power Supplies iGuzzini | | | | | | | | | | Electronic Transformers | | | | | | | | | | A | | W | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | code | W output | h Average operational life | dimmer guarantee device | V output voltage | maximum absorbed current | temperature test Tc | mains dissipated power | V spike protection | Electronic Safety Transformer | N° input terminals | N° output terminals | Kg weight | mm dimensions | | | | 5586 | 50-200 | 50.000/70.000 | 6 | IGBT | 11,7 | 0,86 | +80 | <10 | >1800 | SELV | 4 | 8 | 0,345 | 238x50x43 | | | | G400 | 50-150 | 50.000/70.000 | 6 | IGBT | 11,7 | 0,65 | +75 | <6 | >1800 | SELV | 4 | 6 | 0,320 | 238x50x43 | | | | 5587 | 50-200 | 30.000/45.000 | 4 | IGBT | 11,7 | 0,86 | +80 | <10 | >1400 | SELV | 2 | 8 | 0,345 | 238x50x43 | | | | G401 | 50-105 | 30.000/45.000 | 4 | IGBT | 12 | 0,65 | +75 | <6 | >1400 | SELV | 2 | 6 | 0,365 | 238x50x43 | | | | G402 | 50-200 | 30.000/45.000 | 4 | IGBT-TRIAC | 11,7 | 0,86 | +80 | <10 | >1400 | SELV | 2 | 8 | 0,345 | 238x50x43 | | | | G407 | 50-200 | 20.000/25.000 | 3 | IGBT | 11,5 | 0,87 | +80 | <11 | >1100 | SELV | 2 | 8 | 0,330 | 238x50x34 | | | | 6071 | 50-150 | 20.000/25.000 | 3 | IGBT | 11,5 | 0,65 | +75 | <8 | >1100 | SELV | 2 | 8 | 0,330 | 238x50x34 | | | | 5585 | 50-105 | 30.000/45.000 | 4 | IGBT-TRIAC | 11,7 | 0,49 | +75 | <4,5 | >1400 | SELV | 2 | 4 | 0,210 | 178x47x34 | | | | 5584 | 20-60 | 30.000/45.000 | 4 | IGBT-TRIAC | 11,7 | 0,29 | +70 | <4 | >1400 | SELV | 2 | 4 | 0,165 | 178x47x34 | | | | G404 | 35-105 | 30.000/45.000 | 4 | IGBT | 11,6 | 0,49 | +85 | <4,5 | >1400 | SELV | 2 | 6 | 0,130 | 168x48x17 | | | | 5583 | 35-105 | 30.000/45.000 | 4 | IGBT | 11,6 | 0,49 | +85 | <4,5 | >1400 | SELV | 2 | 2 | 0,130 | 168x48x17 | | | | G403 | 10-60 | 30.000/45.000 | 4 | IGBT | 11,6 | 0,26 | +80 | <4 | >1400 | SELV | 2 | 6 | 0,120 | 168x48x17 | | | | 5581 | 10-60 | 30.000/45.000 | 4 | IGBT | 11,6 | 0,26 | +80 | <4 | >1400 | SELV | 2 | 2 | 0,120 | 168x48x17 | | | | 5582 | 50-105 | 50.000/70.000 | 6 | IGBT | 11,6 | 0,49 | +85 | <4,5 | >1800 | SELV | 2 | 6 | 0,130 | 168x48x17 | | | | 5580 | 20-60 | 50.000/70.000 | 6 | IGBT | 11,6 | 0,26 | +80 | <4 | >1800 | SELV | 2 | 6 | 0,120 | 168x48x17 | | | | G406 | 35-105 | 20.000/25.000 | 3 | IGBT | 11,6 | 0,49 | +75 | <4,5 | >1100 | SELV | 2 | 2 | 0,105 | 114x52x23 | | | | G405 | 20-70 | 20.000/25.000 | 3 | IGBT | 11,6 | 0,33 | +75 | <4 | >1100 | SELV | 2 | 2 | 0,100 | 114x52x23 | | | | 6070 | 35-105 | 20.000/25.000 | 3 | IGBT-TRIAC | 11,6 | 0,49 | +75 | <4,5 | >1100 | SELV | 2 | 2 | 0,105 | 114x52x23 | | | | 6002 | 20-70 | 20.000/25.000 | 3 | IGBT-TRIAC | 11,6 | 0,33 | +75 | <4 | >1100 | SELV | 2 | 2 | 0,100 | 114x52x23 | | | | G409 | 35-105 | 10.000/15.000 | 2 | IGBT | 11,5 | 0,49 | +75 | <4 | >1000 | EQUIV. SELV | 2 | 2 | 0,080 | 100x38x32 | | | | G408 | 20-60 | 10.000/15.000 | 2 | IGBT | 11,6 | 0,29 | +75 | <4 | >1000 | EQUIV. SELV | 2 | 2 | 0,080 | 100x38x32 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | The electronic transformers have the following features in common: 230 V ±10% /12 V o 240 V +6/-10% / 12V Power factor 0,97/0,98 iQ Independent electronic transformer: can be installed separately, externally of a lighting appliance, without an additional housing. I □ J Class II insulation: no earth connection required. \^ Thermally protected electronic transformer; the number within the triangle indicates the nominal maximum temperature of the casing in °C. ^ Electronic transformer suitable for installation on normally inflammable surfaces Electronic transformer suitable for installation on wood surfaces in compliance with DIN VDE 0710/14. ^3 Safety transformer with short circuit protection.ti. | | Ta | | Ambient temperature -20°+55°C Overload protection Active Protection Permanent short circuit protection Thermal protection No load protection CE mark Compliance with Norm EN 61347-2-2 Compliance with Norm 55015 Soft Start lamp ignition "Soft Start" | | | | | | | | | | | | | | | | | | Electronic power supplies with HIT long life | | | | | | | | | | | | | | | | | | | | | | | | | | | | code | W output | h Average operational life | guarantee | efficiency | A maximum absorbed current | °C temperature test Tc | mm Lamp cable length | min max switch-on time | N° input terminals | exit | Kg weight | mm dimensions | | | | G603 ' ■■■■■ | 70 | 50.000/70.000 | 6 | >90% | 0,35 | +70 | 500 | 20 | 6 | lamp cable | 0,400 | 152x87x39 | | | | U_-_l G602 | 35 | 50.000/70.000 | 6 | >90% | 0,18 | +75 | 500 | 20 | 6 | lamp cable | 0,400 | 152x87x39 | | | | | | | | | | | | | | | | | | | | | | | | | | | | Electronic power supplies have the following features in common: 230 V ±10% /240 V +6/-10% Power factor >0,97 (Q Independent electronic power supplies: can be installed separately, externally of a lighting appliance, without an additional housing I □ J Class II insulation: no earth connection required. y^y Thermally protected electronic power supplies the number within the triangle indicates the nominal maximum temperature of the casing in °C. ■\j7 Electronic power supplies suitable for installation on wood surfaces in compliance with DIN | | Ta | | Ambient temperature -20°+50°C Active Protection Permanent short circuit protection Thermal protection No load protection grounding operational for EMC grounding operational relaunching CE mark Compliance with Norm EN 61347-2-12 | | | | | | | | | | | | | | | | | | electronic dimmers | | | | | | | | | | temperature | | | | | | | | | | | | | | | | | | | | | | | | | code | W output | Average operational life | guarantee | dimmer technology | feature | test Tc | type of application | type of connection | type of command | Kg weight | mm dimensions | | | | .ffi= | =^ G744 | 50-700 | 30.000/45.000 | 4 | IGBT | Booster | +70 | independent | terminals | via G743 | 0,400 | 212x49x46 | | | | -41 | «\ G743 | 50-700 | 30.000/45.000 | 4 | IGBT | Dimmer | +70 | independent | terminals | button normally open | 0,400 | 212x49x46 | | | | | | | | | | | | | | | | | | | | n—1 | G742 | 60-300 | 30.000/45.000 | 4 | TRIAC | Dimmer | +75 | can be added | three wires | button normally open | 0,200 | 81x43x20 | | | | | | | | | | | | | | | | | | | | | | | | | | | | The electronic dimmers and the boosters have the following features in common: 230 V ±10% Ambient temperature 40°/45°C Permanent short circuit protection Thermal protection CE mark Compliance with Norm EN 60669-2-1 | | The dimmers and the boosters allow users to regulate the halogen low voltage lamp intensity with electronic transformers, 230 V incandescent lamps and halogen AV lamps. Max of 10 G744 can be connected to the G743 | | | | | | | | | | | | | | 664 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|