Catalogue New 2007/2008
www.iguzzini.it
print switch display
Page / 686
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
iGUZZINI ILLUMINAZIONE - 110087
/ 686
See other catalogues for iGUZZINI ILLUMINAZIONE
Text version of the page

Scene Equalizer

design Maurizio Varratta iGuzzini Example of a project with the SceneEqualizer control system This example is to scale and depictsa multifunctional space with 2conference rooms (space 1 and 2), 1 meeting room (space 3),and 1 reception area (space 4).The Scene Equalizer system allows us to adapt the lighting to the different ways the space couldpotentially be used. The fittings connected to the system are managed via the DALI protocol. In this particular example, the lightingproject was designed with electronicDALI Base Lighting and halogen Frames with DALI electronictransformers.Light management is performed via: •a control unit positioned on theinside of the electric panel•1 Scene Central panel placedin the area where the main stage is located•2 Scene Zone panels placed in theareas where the stage and thereception area are located •4 interfaces for standard push-button panels placed at the exitof each space Comprehensively, this system manages 38 Base lightings and 25 Frames for a total of 60 DALIs(it can handle up to 128).
AMBIENTE 1 AMBIENTE 2 AMBIENTE 3AMBIENTE 4 The fittings can be controlled singularly from the Scene Centralpanel and grouped into spaces (up toa maximum of 32) and within each space you can recall up to 16 different set light sequences.These light sequences can be timedand therefore can create patterns of light. 1 Scene Centralpanel 3 interfaces forstandard buttonpanel Recessed BASE LIGHTING 2x54W T5 G5 DALI control gear. What can you do with the system? 2 Scene Zone panels Example of sequences for space 3: •“general meeting” all the fittingswith 100% light emission •“speaker” central Frame ON 100% •“diashow projection” fittings near thewalls ON 50% and central fittingsOFFExample of sequences for space 4: •“day sequence”- all fittings at 100%light flow.•“night sequence”- all lights off exceptbase lighting, dimmed to 20%Example of timed starting forenvironment 4:•“day sequence” activated at 8:00 a.m.•“ night sequence” activated at 8:00 p.m. Control unit
entry General meeting Speaker Projection large round FRAME version:75 W QR 111 24°with DALI electronic transformer.
649
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 651 p.651
page 652 p.652
page 653 p.653
page 654 p.654
page 655 p.655
page 656 p.656
page 657 p.657
page 658 p.658
page 659 p.659
page 660 p.660
page 661 p.661
page 662 p.662
page 663 p.663
page 664 p.664
page 665 p.665
page 666 p.666
page 667 p.667
page 668 p.668
page 669 p.669
page 670 p.670
page 671 p.671
page 672 p.672
page 673 p.673
page 674 p.674
page 675 p.675
page 676 p.676
page 677 p.677
page 678 p.678
page 679 p.679
page 680 p.680
page 681 p.681
page 682 p.682
page 683 p.683
page 684 p.684
page 685 p.685
page 686 p.686
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-400
401-450
451-500
501-550
551-600
601-650
651-686
pdf-page pdf ae En 2008-11-47-22