Flush mounted QuietVent ELS-programone room ventilation

Spare permanent filter for ELSfans, can be cleaned in dish washer (Contents: 2 pcs.). Spacer frame if casing protrudes from wall or ceiling. Electronic overrun timer with adjustable run on time3, 7, 10, 15 minutes. Overrun and interval timer.Run on times as ZNE, intervals4,8, 12,24 hours. Electronic overrun timer with stepless adjustable run on time (4-15 minutes). Thermal overrun timer with variable run on time. Used with light switch.

Fan unit includingfacia Type, Ref. No., Specification

Specification see pages 277-278. Coloured facias.Overview see page 56.

(For final fix)

ELF/ELSD Ref. No. 0587 ELS-WF/.. ZT Ref. No. 1277 ZNE Ref. No. 0342 ZNI Ref. No. 0343 ZV Ref. No. 1279 DSEL 2 Ref. No. 1306 2 speed on/off switch. ELS-AR Ref. No. 20698 Accessory

60 m

3

/hDesigned air flow volume

ELS-VE 60/30 Ref. No. 0535 Fan unit with 2 speeds (60/30 m 3 /h) for general and trickle ventilation
.With facia, attenuation plate and quick plug connector for electrical connection. Insulationclass II, protection to IP 55, for installation in zone 1 of bathrooms. Maintenance free, energy saving ball bearing motor 230 V / 1 ph. / 50 Hz, 16/8 W. Flat facia (white), acoustically linedfor low noise levels.Indicator to monitor the pemanent filter. Filter changed in seconds. Sound levels: sound power: 40/33 dB(A), sound pressure 36/29 dB(A). Approval No. Z-51.1-56ELS-VEZ 60/30 Ref. No. 0536 ELS-VE 60 Ref. No. 0425 Fan unit with 60 m With built-in overrun timer and delayed start (approx.1 min.) Run on time 5 – 6 min. (variable by running time and temperature). Other details asELS-VE 60/30. 3 /hair flow volume, 230 V / 1 ph. / 50 Hz, 16 W. Sound levels: sound power: 40 dB(A), sound pressure 36 dB(A). Other details as ELS-VE 60/30. ELS-VEB 60 Ref. No. 0509 Fan unit with 60 m ELS-VEZ 60 Ref. No. 0426 Fan unit with 60 m 3 /hair flow volume, built-in overrun timer and delayed start (approx. 1 min.). Run on time 5 – 6 min. (variable byrunning time and temperature). 230 V / 1 ph. / 50 Hz, 19 W. Other details as ELS-VE 60. 3 /hair flow volume and built-in PIR detector for automatic runwhen room is occupied and run on (3, 7, 10, 15 min. adjustable). Electrical activation without using aswitch. Other details as ELS-VE 60. ELS-VEI 60 Ref. No. 0427 Fan unit with 60 m 3 /hair flow volume with built-in electronic interval timer,overrun timer anddelayed start. Factory set interval 8 hours, run on time 32 minutes. Other intervals and run ontime are adjustable.Maintenance free, energy saving ball bearing motor 230 V / 1 ph. / 50 Hz, 16 W. Sound levels: sound power: 40 dB(A), sound pressure 36 dB(A). Other details as ELS-VE 60. ELS-VEF 60/30 Ref. No. 0515 Fan unit with 2 speeds (60/30 m
3 /h) with built-in electronic dynamic humidity sensor
. Function: Background ventilation at continuous operation. If the set humidity level is reachedthe fan runs automatically on high speed until the room humidity is back to normal. Whenswitched manually (e.g. via light switch) high air flow volume with overrun timer. ELS-VEF 60 Ref. No. 0431 Fan unit with 60 m 3 /hair flow volume. Other details as ELS-VEF 60/30.

100 m

3

/hDesigned air flow volume

ELS-VE 100 Ref. No. 0429
Fan unit with 100 m 3 /hair flow volume.Maintenance free, energy saving ball bearing motor 230 V / 1 ph. / 50 Hz, 33 W.
Sound levels:sound power: 47 dB(A),
sound pressure 43 dB(A).
Other details as ELS-VE 60/30. ELS-VEZ 100 Ref. No. 0434
Fan unit with 100 m 3 /hair flow volume and built-in overrun timer (Function as ELS-VEZ ..).
Other details as ELS-VE 100. ELS-VEZ 100/60 Ref. No. 0430
Fan unit with 2 speeds (100/60 m
3 /h) and
overrun timer .
Sound levels :
sound power: 47/40 dB(A),
sound pressure 43/36 dB(A).
Other details as ELS-VEZ 60/30. ELS-VE 100/60/40 Ref. No. 0432
Fan unit with 3 speeds (100/60/30 m
3 /h) for general and trickle ventilation.
Sound levels:sound power: DSEL 3 47/40/33 dB(A),
sound pressure 43/36/29 dB(A).
Other details as ELS-VE 60/30.
Ref. No.1611

60 m

3

/hDesigned air flow volume

ELS-VE 60/30 Ref. No. 0535 (Specification see above) ELS-VE 60 Ref. No. 0425 (Specification see above) ELS-VEZ 60/30 Ref. No. 0536 (Specification see above) ELS-VEZ 60 Ref. No. 0426 (Specification see above) ELS-VEB 60 Ref. No. 0509 (Specification see above) ELS-VEI 60 Ref. No. 0427 (Specification see above) ELS-VEF 60/30 Ref. No. 0515 (Specification see above) ELS-VEF 60 Ref. No. 0431 (Specification see above) Only for wiring on high speed (60 or 100 m
3 /h).

49

ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-250
251-300