Catalogue Standard Range Catalogue
www.heliosventilatoren.de
print switch display
Page / 300
HELIOS VENTILATEURS -
/ 300
See all the products HELIOS VENTILATEURS
Text version of the page
Ceiling sweep fans
■ Ceiling fans
- for cooling in summer
- for energy conservation in winter
For versatile use e.g. to move air for cooling or energy conservation in mid size to large rooms as well as reception and waiting halls, restaurants, disco's, boutiques, wholesale retail outlets, assembly plants, warehouses, tennis and sport halls as well as for industrial drying applications.
Traditionally ceiling fans are used during summer for cooling. Where there are rooms without windows and high heat emission of lamps, ceiling fans solve ventilation problems in many areas. Decorative replicas in "Casablanca" design make Helios ceiling fans an attractive addition to any room. During the heating period, ceiling fans can be used for energy conservation by returning the hot air at the top of the room to the occupied space. In high rooms like sport halls, tennis halls and other industrial halls, slow spinning ceiling fans provide a draft free equal distribution of warm air within the room. This achieves an increase in temperature at the floor level areas of approx. 25% without any additional heating. The energy consumption is negligible.
Reference projects which have been running for many years achieved an average temperature increase of 4 °C in the floor level.
DVW 90
DVAW 130
DVW 140
DVAM 130
■ Ceiling fans DVW range
Classic 3 blade design, robust casing fan made from steel, finished in white. Totally enclosed motor in a white powder paint finish. Maintenance free and radio suppressed, suitable for continuous operation. Resilient mounting ensures low vibration
Simple installation, pre-assembled motor and fixings. Only blades need to be fixed.
Variable down rods using two length down rods. Speed controllable via 5 speed transformer TSW 0.3 (accessory). Reversible air flow direction. Air flow direction to floor or to ceiling by wiring connection or through reversing switch (accessory DSEL 2). TÛV GS approved.'
■ Ceiling fans DVA range
in typical "Casablanca" design for installation in more decorative areas.
Casing made from brass, finished in antique brown or white. Five wooden blades with a wicker finished in nut brown or white. Maintenance free, long life, slot-vented motor with ball bearings for permanent operation. Resilient mounting ensures low vibration.
Simple installation with three different down rod lengths:
- Direct on ceiling (no down rod).
- Short or long down rod (supplied with fan).
Pull cord for three speed on of/off operation. Suitable for connection to remote speed controllers (accessory). TUV GS approved.
■ Selection of a fan
Impeller diameter, position and mounting height are important parameters during design to allow equally coverage of air flow within the room. The room height less the down rod equals the mounting height of the fan. In relation to height and impeller diameter the diagram below shows the area covered by each fan in m2. The distance of the fan's centre to the wall should equal approximately 6 times the impeller diameter. We recommend operation at high speed during summer (cooling) and at low speed in winter (energy conservation).
Blade 0 in mm
10
■ Accessories for DVW and DVA Speed controller
Other accessories
Speed controllers, controllers
Pages
Difference temp. controller EDTW Ref. No. 1613
Varies fan speed automatically in accordance to the temperature difference between high level and low level sensor. Specially for operation in winter for energy saving.
TSW 0.3 Ref. No. 3608
Five step transformer with on/off
function for surface installation.
On reversed operation
(air flow direction to ceiling)
a minimum start voltage of 100 V
is required.
a 8
£ 4
co
275-290
2
co
c 2
25 50 75 100 125 150 175
Floor area per fan in m2
Type
DVW 90
DVW 140
DVAW 130
DVAM 130
Ref. No.
8648
8649
8650
8651
Impeller diameter in mm
900
1400
1300
1300
Number of blades
3
3
5
5
Voltage / Frequency
230 V/1 ph. /50 Hz
230V/1 ph. /50 Hz
230V/1 ph. /50 Hz
230V/1 ph. /50 Hz
Current Amps
0.26
0.30
0.28
0.28
Power Watts
50
65
65
65
Maximum R.PM.
340
270
190
190
Down rods min./max. mm
440/565
460/585
220/360/510
220/360/510
Weight in kg
4.8
6.8
6.7
6.7
I Important installation restriction
Safety regulations ask for a minimum distance of 2.3 m from the bottom of the blades to the floor. Fans should be installed so that they do not interfere with other equipment.
31
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-300