Function

Air quality sensor, differential temperature controllerAir flow switch

Casing Compact casing with air change slots made from light-grey polymer for surface mounting. Technical data Air quality controller Voltage 230 V / 1 ph. / 50/60 Hz Overrun time, adjustable 1 – 10 minutes Delayed startapprox. 5 seconds Current2 A (ind.) Protection toIP 30 Dimensions mmW 125 x H 65 x D 30 Weight 0.2 kg Wiring diagram No. SS-485.1

NEW!

ACL Ref. No. 0492 On/off operation of one or anumber of fans in relation to the room’s air quality. Operation Electronic air quality sensor tocontrol:–1 ph. fans up to max. 1 Amp. –3 ph. fans via contactor The unit has an integrated sensor which reacts on oxidable gases and pollutants like carbon monoxide, alcohol,formaldehydes,methane, tabacco etc. Designed to control ventilation ofpublic buildings like conference rooms, restaurants, shops, domestic rooms etc. Features The unit switches the fan on ifthe set pollution level is exceeded or if the concentration rises quickly. Adjustable (from outside)overrun timer after sensor hasswitched off. Indicator lamp show automaticor manual operation and operation and overrun time. Operation and on/off switch onfront plate. Electronic air flow switch

NEW!

SWE Ref. No. 0065 Technical data Operation Voltage230 V / 1 ph. / 50/60 Hz Current2 A (ind.) Rated value setting range1-9 m/s Air flow temperaturemax. 60 °CAmbient temperaturemax. 60 °CProtection toIP 40 Dimensions mmW 23 x H 78 x D 105 Weight0.4 kg Wiring diagram No. SS-689 To sense air flow speed in ducting. Optional closing oropening contact when no airflow.
N and position ofthe output relay. It’s possible to connect an external failure display via relay output Volt free contact (single poledouble throw), max. current 5 A / AC 250 V). Function Installation The air flow speed sensor (connected to controller) registers the air flow and compares it with the preset rate value. That can be set on the front of the unit (in the range from1 – 9 m/s). Relay contacts if the set valueis reached or exceeded. Thisfunction can be inverted on the bottom of the unit. TwoLED’s show U Controller suitable to be mountedin fuse board on 35 mm rails. Mechanical air flow switch Features Technical data SWT Ref. No. 0080 Can be used to make or brakecircuit connections. Voltage230 V / 1 ph. / 50/60 HzCurrent8 A (ind.)Air flow temperaturemax. 80 °C Ambient temperaturemax. 55 °C Protection toIP 54 Dimensions mm– PaddleW 55. L 175– CasingW 100 x H 60 x D 62 Weight0.5 kg Wiring diagram No. SS-557 Operation Adjustable mechanical air flowswitch to sense minimum/maximum air flow speed inducting. Suitable from duct size 250 on. Unit may be set to respond if aminimum or maximum air flow isachieved. Description Adjustable min. air flow setting:…Lower than 1.5 m/sec.…Higher than 3 m/sec. Differential temperature Robust design with a sensingpaddle from high-grade steel.Comes with a mounting plate to fix unit in the casing. Suitable from duct size 250 on. Installation The unit must be installed in a way that the weight of the paddle does not affect the spring mechanism inside the unit. Function Technical data Voltage230 V / 1 ph. / 50/60 Hz Current max.2.5 A (D 40 E) Control range, adjust.1 – 10 K Protection toIP 20Dimensions mmW 210 x H 85 x D 55Weight 0.7 kg Wiring diagram No.SS-438 Features

NEW!

controller The fan speed is controlled stepless from 0 – 100 % in relation to temperature difference between the two remote sensors and the setrate value. EDTW Ref. No. 1613 Operation and advantages Electronical, stepless differentialtemperature controller forconnection of electronically speed controllable –ceiling fans and all 1 ph. fans. Two sensors with a flying lead(1 x 10 m for installation beneaththe ceiling; 1 x 2 m for installation above the floor). For continuous speed control tothe temperature difference. On/off (with function control) If the temperature differencerises, the fan speed increasesproportionally and slows downfor falling temperature. Automatic or manual operation. Designed for use in combinationwith ceiling fans or fans whichmove room air towards the floorto save heating energy. The unit optimises the differencebetween floor and ceiling temp. Reversing of air flow. Proportional range. Casing Summer operation:as manual speed controller.Depending on the fan type, motorhumming might be caused. Air flow sensor with mountingrosette for in-duct installation withcable, that is to be connected tothe controller. Impact resistant white polymer casing for flush or surface installation. Proportional range can be adjusted stepless from 1 … 10 K. 289
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 251 p.251
page 252 p.252
page 253 p.253
page 254 p.254
page 255 p.255
page 256 p.256
page 257 p.257
page 258 p.258
page 259 p.259
page 260 p.260
page 261 p.261
page 262 p.262
page 263 p.263
page 264 p.264
page 265 p.265
page 266 p.266
page 267 p.267
page 268 p.268
page 269 p.269
page 270 p.270
page 271 p.271
page 272 p.272
page 273 p.273
page 274 p.274
page 275 p.275
page 276 p.276
page 277 p.277
page 278 p.278
page 279 p.279
page 280 p.280
page 281 p.281
page 282 p.282
page 283 p.283
page 284 p.284
page 285 p.285
page 286 p.286
page 287 p.287
page 288 p.288
page 289 p.289
page 290 p.290
page 291 p.291
page 292 p.292
page 293 p.293
page 294 p.294
page 295 p.295
page 296 p.296
page 297 p.297
page 298 p.298
page 299 p.299
page 300 p.300
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
pdf-page pdf ae En 2008-12-49-04