ABLUVENT ABVCross talk attenuator ETS

ABV 100 ETS
Valve ETS attenuator verticalshaft All dim. in mm Unit setting Vm ρ = 1,20 kg/m 3 Attenuation of ETS,installation with valveWithout cross talk attenuator, only with valve Installation example Cross talk attenuator ETS (shown inserted in ducting with valve) ∆ p Pa fa 50321T* ETS 100 ETS 125 Function Advantages
T* = Trickle ventilation 3 /h The ABLUVENT is a grille with an electrically operated shutter to control the air flow. The unit includes a filter. It is ideally operated via the light switch. The louvres open when the room is in use (light is switched on). A trickle ventilation is given when the room is not used, as a minimum air flow will be extracted when the shutter is closed. ABLUVENT ABV 100 Delayed operation on closure of5 minutes. Cross talk attenuator ETS Advantages Optimises the economic efficiency of central ventilation systems. Ventilation systems for toilets and bathrooms withoutwindows must operate 24 hours.If traditional valves are installed, the full air flow is extracted e.g. for 18 hours and half the air flow for 6 hours at night no matterof how often the room is used.This means a lot of energy is lost. Using of ABLUVENT can, depending on the building, bring energy savings of up to30%. Surprisingly simple and cost effective solution to reduce noise transmission in central ventilation systems. Installation direct into ducting behind the valve. Optimal solution to avoid noisetransmission by duct system. Stepless adjustment of air flowvolume. Attenuation figure The attenuation figure can be doubled if you have two facingrooms which both have an ETSattenuator in the ducting. Excellent attenuation figures(see diagram). Noiseless operation. Incorporating (changeable) filterto keep duct system clean. Simple installation by pressinginto ducting (behind valve). Material Air flow volume Polyurethane foam with improved reaction in case of fire, fulfills DIN 4102, class B1, UL-94-HF 1, MVSS 302 and others. Virtually no additional resistanceto the system. The opening pitch of the louvres can be set stepless between 15and 80 degrees (covered, insidefacia). The diagram above shows the air flow in relation to the setting (under pressure). Technical data Connection Minimizing system cost by usingsimpler ducting. The unit can be operated using a standard on/off switch, ideally combined with the light switch.Supply: 220/240 V / 1 ph., power: 5 W. Double insulated, radio suppressed, protection to IP 44. Casing made from white polymer. The thermal shutter works withshort delay (approx. 30 secondsto open and 5 minutes to close). Can be used with any brand ofvalve. ETS 100 Ref. No. 4521 Nominal duct 100 mm ETS 125 Ref. No. 4522 Nominal duct 125 mm
Cut: Vertical system Cut: Horizontal system ABV 100 Ref. No. 0452 Energy savings. Accessory Cost effective solution. ELF/ABV Ref. No. 6906Spare filter mats, contents = 5 pcs.
Valve Valve Quick installation.
ETS attenuator ETSAttenuator Is always an optimum solution. 263
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 251 p.251
page 252 p.252
page 253 p.253
page 254 p.254
page 255 p.255
page 256 p.256
page 257 p.257
page 258 p.258
page 259 p.259
page 260 p.260
page 261 p.261
page 262 p.262
page 263 p.263
page 264 p.264
page 265 p.265
page 266 p.266
page 267 p.267
page 268 p.268
page 269 p.269
page 270 p.270
page 271 p.271
page 272 p.272
page 273 p.273
page 274 p.274
page 275 p.275
page 276 p.276
page 277 p.277
page 278 p.278
page 279 p.279
page 280 p.280
page 281 p.281
page 282 p.282
page 283 p.283
page 284 p.284
page 285 p.285
page 286 p.286
page 287 p.287
page 288 p.288
page 289 p.289
page 290 p.290
page 291 p.291
page 292 p.292
page 293 p.293
page 294 p.294
page 295 p.295
page 296 p.296
page 297 p.297
page 298 p.298
page 299 p.299
page 300 p.300
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
pdf-page pdf ae En 2008-12-49-01