Air extract elements AESelection chart, elements with constant air flow volume
Selection Operation AE..
NEW!
Use the table below to select the correct extract element, selection depends
on volume and application. There is a choice of element designs, with
constant airflow with one or two air volume steps, two volume steps with
timer and with humidity controlled operation. Air extract elements with self contr olling constant air flow are the ideal components for
extraction of kitchen, bathroom
and toilet for central ventilationsystems in houses. Advantages
MediumLowHigh >
Constant air flow volume between 40 and 160 Pa.
TypeRef. No.TypeRef. No.TypeRef. No. >
Adjusting and balancing of system are not necessary.
Constant air flow volume controller , self controlling >
Attractive design.
AE 45* 2031 AE 30* 2030 AE 75* 2033 >
High quality construction in anaerodynamic shape with lowsound levels.
Two air flow volumes , (trickle and general ventilation) constant air flow control, self controlling. >
Offering an airtight seal againstthe wall.
AE GB 20/75* 2036 AEGB 15/30* 2035 AEGB45/120* 2038 >
Easy cleaning without the risk ofair flow volume changing.
Two air flow volumes with electrical timer (without constant air flow volume control) AEGBE30/60* 2047 AEGBE15/30* 2044 AEGBE 45/120* 2048 >
Specification Extract element with mounting
ring, ready to install, made from
white polymers to be inserted inducts with nominal diameter
Humidity controlled with variable, limited air flow volume, page 260 AEHygro 10/45* 2049 Humidity controlled with electrically controlled general ventilation, page 260 >
125 mm. Lip rubber seal on mounting ring to avoid air leakage on the sides.
AEHygro GBE 5/40/75* 2053 AEHygro GBE 10/45/120* 2054 * Air flow volume in m³/h >
Function Effects constant air flow volume at different pressure conditions between 40 and 160 Pa. Contents Supplied as one element incl. mounting ring.
Dimensions in mm Installation Accessory Suitable for wall and ceiling installation. Mounting ring to be
fixed via screws on duct or wall
openings and extract element tobe inserted. For an even air flow a straight
duct of approximately 300 mm
is required. Attenuator AESD to be insertedbehind the element.
(Ref. No. 2059) Filter elements: on request
140120
100806040
200
/h 3 AE 75 AE 45 AE 30
Air flow curve AE.. Acoustical data for extract elements of models AE..
Air flow volume m Following sound levels are relevant for the extract elements:–Sound levels created by the air flow (L
w in dB (A) >
)–Acoustical damping between ducting system and room to be ventilated. (D
40 60 80 100 120 140 160
n,e in dB (A) >
). Differencial pressure in Pa This sound data is given in the table. Measured according to regulationE51701.
The attenuation can be increased by using attenuators„AESD“ or „AESE“(accessory). To be positioned and inserted behind the extract element. Cross talk attenuators are available for further acoustical reduction (page 263).
Order dataSound levesAttenuation L >
w in dB(A)D >
n,e in dB(A) 100 Pa130 Pa160 PawithoutwithTypeRef. No.AESDAESDAE 30* 20303033366064 >
1) AE 45* 20313334375663 >
1) AE 75* 20333536395764 >
1) 1) Equiped with attenuator AESD (accessory). *Air flow volume in m >
3 /h >
258