General product information

The perfect technical solution isof highest priority for HELIOS. Experience and consistent development of ideas and methods has resulted in world wide acceptance of HELIOS products.Research and development arereflected in an extensive productrange which offers the technical solution for most applications. HELIOS is also your partner if more sophisticated specials arerequired. The combination of thelatest technology with the hig- hest quality and design lead to many product advantages like:–Economical operation throughhigh efficiency products. Impel-lers and motors were developed in house and are perfectly tuned for each other. –Highest reliability even undertoughest working conditions isgained by use of impregnated windings, sealed for life ball bearings, quality checks etc.–Economic adjustment of performance through speed controllable motors using transformer or electronic speed controllers.–Innovative aerodynamical designof parts and components.–Low noise levels make HELIOSfans some of the quietest availa- ble.–Easy installation and maintenancefree operation in combinationwith highest electrical and mechanical safety standards are most beneficial for installer and user. Design of HELIOS motors Electrical data Voltage, frequency, current, absorbed or nominal motor power, protection class and the wiring diagram number for the fan can be found in the fan’s data table. The figures relate to normal operating conditions (density –Casing made of aluminium orcast iron, totally enclosed with cooling fins. Protection class: see individual model.–Bearings: maintenance free (sealed for life) and dust proof through double lip sealing. Lubrication graded from -40 to+140 °C.–Full immersion, tropical moistureprotection to windings, insulation class B. Ï = 1.2 kg/m Operation of fans Motors Factors which are individual to each installation have an influence on the fan’s performance as well as the electrical and mechanicalsafety.Before installation/use of fan and accessories, the operation and requirements of the fan system must be clarified. The equipmentmust not be used for purposesfor which it is not intended. Fans make special demands on motors. Therefore HELIOS develop and manufacture many of their own motors, especially the speed controllable models.This guarantees optimal matching to the fan’s needs. This results in a range of specia- lised drives serving the individual fan’s requirement.This guarantees for example:–Superb speed control –Low consumption –Low maintenance –Trouble free operation evenunder difficult conditions. –Conformance to all relevantregulations likeVDE 0530 and 0700, DINIEC 2J and IEC 61.
3 , temperatureT = 20 °C, 50 Hz). The actual figures may vary depending on the installationconditions. When installing theequipment the electrical figures stated on the rating plate must be observed. For other environmental condi-tions, in particular at low tempe-ratures, an increase in the current and power figures can be expected. This needs to be considered when sizing the electrcial supply (wires, contac-tors, circuit breakers). If in doubtconsult HELIOS. All other motors used byHELIOS are manufactured toIEC standard and conform withall relevant regulations. Theirspecification may vary. Specialsare available on request. Performance curves Technical data (power, noise figures, etc.) are stated in accor-dance with DIN24166 ‘Technicalconditions of sale’, tolerance classes 2 or 3, DIN44974, Pt.1-3 ‘electrical domestic appliances’, DINVDE0700. Noise levels Noise figures are given as A rated sound power levels and/or sound pressure levels at a distance of 1 or 4 metres. The levels are illustrated in theperformance curves and fandata tables. The sound pressure levels are for freefield conditions and may be affected by reflections of wallsetc. The figures relate to thedetails given in chapter ‘perfor- mance data’ and are in accor- dance with DIN 24166. Installa- tion conditions may increasenoise levels, in some cases substantially. If no other references are made, the noise levels represent the air noise on the intake. All figureswere measured in accordancewith DIN 45635, Part 38. The Air performance Available pressure and air flow volume are stated in performancecurves on the individual productpages. All performance data is determi-ned on test stands to DIN24163, Pt.2. and Pt. 3. Air flow volume and staticpressure total pressure ∆ p ∆ p
stat. for air flowdirection A(at free intake and extract) are measured. The
tot is calculated by adding the dynamic pressure p
dyn. (from the crosssectional area). Ducted fans are measured witha bell mouth on the intake andducting of 1 diameter of the fanin length attached on the outlet.If the installation varies from this(obstructions, bends, etc.) areduction in performance mustbe taken into account. HELIOS – reverberent chamber to DIN24163, Pt. 2
Unit under test The performance curves relateto an air density of
Determination of air flow volume Chamber Damper Ï =1.2 kg/m
3 and to the given nominal R.P.M.figure. The actual speed of the individual fans may vary and arestated in the related tables.The air flow velocity c and the dynamic pressure p
dyn. relate tothe extract cross sectional area (casing cross sectional area). 17
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-300