Centrifugal in-line fan 250 mm InLineVent


RR, RRK and SilentBox

Accessories for RRand RRKPipe clamp connectors RR 250 A
FrequencyHzTotal1252505001k2k4k8k L WA Case breakoutdB(A)5535424550484633 L WA IntakedB(A)7262676767646247 BM 250 Ref. No. 5079A quick-fix method for connecting fans to ducting, reducing vibrationtransmission. When installing leavea little gap between fan and ducting. Supplied in pairs. RR 250 CRRK 250SB 250 C
FrequencyHzTotal1252505001k2k4k8k L WA Case breakoutdB(A)6240425258585250 L WA IntakedB(A)7352666768656460 FrequencyHzTotal1252505001k2k4k8k L WA Case breakoutdB(A)6046495256555141 L WA IntakedB(A)6853566461605747 Mounting feet for RR
FrequencyHzTotal1252505001k2k4k8k MK 4 Ref. No. 5824
L WA Case breakoutdB(A)4434354038342922 Mounting feet for RRK
L WA IntakedB(A)5952565143393929 MK 2 Ref. No. 5822To fix fan on wall, floor or ceiling; made from galvanised steel.
∆ p stat. L WA ExhaustdB(A)7159636266656152 Pa ρ = 1.20 kg/m 3 Accessories for all modelsBackdraught shutter RR 250 C RRK 250 RSK 250 Ref. No. 5673Air stream operated, metal. Gravity shutter VK 250 Ref. No. 0759Air stream operated, polymer, light-grey. SB 250 C Rain repellent grille RAG 250 Ref. No. 0751From polymer, light-grey.

*

RR250 A Guard for spigot connection SGR 250 Ref. No. 5067For intake and exhaust installationon fan, made from galvanisedsteel.

*

Consider required minimum system resistance. V.m 3 /h cm/s Sound levels Flexible attenuator Total sound power levels and the spectrum figuresin dB(A) are given for case breakout intake and exhaustin the tables above the performance curves.In addition the case breakout figure is given as a sound pressure level at 1 metre (freefield conditions) in the technical data table (see facing page).Note: For silentbox the sound level on intake is lower than onexhaust.
InformationPages Technical description148 Selection chart149Design of systems12-16Modular comp. system150 FSD 250 Ref. No. 0680
Spigotted aluminium attenuatorwith 50 mm insulation. Length: 1 m. Spigotted attenuators SRSD 250/... see page 219
Spigotted attenuator with 50 mminsulation. Available in four lengths:300/600/900/1200 mm. In-line air filter box LFBR 250 Ref. No. 8580Air filter with big cross sectional area to be installed in-line with ducting. Spigots incorporate twin-seal rubber sealings to fitstandard size ducting. Electric heater battery EHR-R 6/250 Ref. No. 8712In duct casing made from galvanised sheet steel, for in-line installation. Water heater battery LPHW
Other accessoriesPages WHR 250 Ref. No. 9483Compact unit for in-line installation. Information for ducting systems All Helios components fit standard nominal duct diameters. The ducting usedmay be rigid, flexible made from aluminium, galvanised steel or plastic. Observe fire protection regulations where applicable.
Filters and heater batteries211-220 Flexible ducting, guards, duct componentsand roof outlets245-256 Valves257-263 Speed controllers and switches275-290 Transformer speed controller TSW 1.5 Ref. No. 1495 Electronic speed controller for RR and RRK ESA1 Ref. No. 0238 for SB ESA3 Ref. No. 0239 161
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 151 p.151
page 152 p.152
page 153 p.153
page 154 p.154
page 155 p.155
page 156 p.156
page 157 p.157
page 158 p.158
page 159 p.159
page 160 p.160
page 161 p.161
page 162 p.162
page 163 p.163
page 164 p.164
page 165 p.165
page 166 p.166
page 167 p.167
page 168 p.168
page 169 p.169
page 170 p.170
page 171 p.171
page 172 p.172
page 173 p.173
page 174 p.174
page 175 p.175
page 176 p.176
page 177 p.177
page 178 p.178
page 179 p.179
page 180 p.180
page 181 p.181
page 182 p.182
page 183 p.183
page 184 p.184
page 185 p.185
page 186 p.186
page 187 p.187
page 188 p.188
page 189 p.189
page 190 p.190
page 191 p.191
page 192 p.192
page 193 p.193
page 194 p.194
page 195 p.195
page 196 p.196
page 197 p.197
page 198 p.198
page 199 p.199
page 200 p.200
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
pdf-page pdf ae En 2008-12-49-01