800 mm ø Axial fans

Specification Electrical connection Casing Terminals in motor cap (IP 54).

With motorsupportmanufacturedfrom galvanised sheet steel.

Guard AVD DK models have hot dipped zinc plated motor sidewire guard to EN 294. Impeller Highly efficient, profiled 5 or 7 blade impeller, dynamically balanced and manufacturedfrom impact resistant polymers(explosion proof models from steel). Suitable for –30 to +60 °C. Speed control Some models are controllableby a transformer control (see table). All models (except explosion proof) are speed controllable by frequency inverter. AVD DK AVDRK

All dimensions in mm

Pitch angle The pitch angle is adjustable atstandstill (expect explosion proof) and has to be stated when ordering. The max. pitch shown for each motor must notbe exceeded. Reversed operation All models are reversible when wired to a reversing switch. For reverse air flow direction allowfor

1

/

3

drop in performance. Motor Totally enclosed motor, protected to IP 54/ IP 55.Sealed for life ball bearings withtropical protection of windings and radio suppression. Installation Installation in any position. Ensure that motor drainageholes face downwards.

Dimension B see tableDimension B see table

Dimensions Motor protection Dimensions are shown above.Pole-switching and explosion proof models may vary.Note dimension B in table below. All models (except pole switchingand explosion proof) have thermal contacts which must be connected to a motor protection unit (see table).All other models must be protected by a conventional circuit breaker (MCB/RCD). Sound levels Sound power levels in dB(A) (spectrum and totals) are given above the performance curves.

R.P.M. Air flowvolume(FID) Motorpower(nominal) Voltage
Currentat full load Max.pitchangle Wiringdiagram Max.air flowtemp. Nominalweight(net) Fan type Dim. BFlange/Footmotor Transformer controllerorPole switch AVD DK Ref.No. AVD RK Ref.No. incl.guard min
-1 V·m
3 /h kW VA ° No. +°C kg mm Type Ref. No. 3 Phase motor, 50 Hz, protection to IP 54 5 speed transformer 695 17780 0.55 400 2.0 32 776 40 73 AVD DK 800/8/..
3) 5305 AVD RK 800/8/..
3) 6954 135 — — 1445 33450 4.00 400/690 8.9 26 776 40 101 AVD DK 800/4/..
3) 5311 AVD RK 800/4/..
3) 6960 210 — — 1450 39190 5.50 400/690 11.5 33 776 40 115 AVD DK 800/4/..
3) 5312 AVD RK 800/4/..
3) 6961 290 — — 2 speed motor, 3 Phase, 400 V / 3 ph. / 50 Hz,Y/ -motor, protection to IP 55 580/685 15740/18590 0.40/0.67 400Y/

∆

1.0/2.9 35 520 40 86 AVD DK 800/8/8/..
4) 5306 AVD RK 800/8/8/..
4) 6955 180 RDS 4
5)6) 1316 775/920 15720/18670 0.43/0.75 400Y/

∆

1.2/2.2 22 520 40 70 AVD DK 800/6/6/..
4) 5307 AVD RK 800/6/6/..
4) 6956 125 RDS 4
5)6) 1316 755/930 19430/23930 0.71/1.32 400Y/

∆

2.1/3.5 32 520 40 98 AVD DK 800/6/6/..
4) 5309 AVD RK 800/6/6/..
4) 6958 180 RDS 4
5)6) 1316 2 speed motor, pole-switching, 3 ph. / 50 Hz, protection to IP 54 Pole switch 450/900 8595/17190 0.12/0.55 400/400 0.6/1.6 20 471 40 80 AVD DK 800/12/6/..
1) 5316 AVD RK 800/12/6/..
1) 6965 135 PDA 12 5081 455/940 10945/22610 0.25/1.10 400/400 1.2/2.9 29 471 40 88 AVD DK 800/12/6/..
1) 5317 AVD RK 800/12/6/..
1) 6966 180 PDA 12 5081 455/950 12350/25780 0.33/2.00 400/400 1.9/5.0 35 471 40 98 AVD DK 800/12/6/..
1) 5318 AVD RK 800/12/6/..
1) 6967 290 PDA 12 5081 695/1400 10020/20180 0.37/1.50 400/400 1.4/3.7 12 471 40 95 AVD DK 800/8/4/..
1) 5319 AVD RK 800/8/4/..
1) 6968 135 PDA 12 5081 700/1435 15810/32410 0.90/3.60 400/400 3.4/8.0 25 471 40 103 AVD DK 800/8/4/..
1) 5320 AVD RK 800/8/4/..
1) 6969 210 PDA 12 5081 715/1450 20110/40780 1.80/6.50 400/400 5.7/14.5 35 471 40 121 AVD DK 800/8/4/..
1) 5321 AVD RK 800/8/4..
1) 6970 325 PDA 25 5060 970/1440 15880/23580 0.75/2.10 400/400 2.3/4.6 15 473 40 95 AVD DK 800/6/4/..
2) 5322 AVD RK 800/6/4/..
2) 6971 180 PGWA 12 5083 965/1435 19515/29020 1.00/3.00 400/400 2.9/6.6 21 473 40 116 AVD DK 800/6/4/..
2) 5323 AVD RK 800/6/4/..
2) 6972 210 PGWA 12 5083 970/1450 27280/40780 2.20/6.00 400/400 5.6/12.5 35 473 40 128 AVD DK 800/6/4/..
2) 5324 AVD RK 800/6/4/..
2) 6973 325 PGWA 25 5061 Explosion proof E Exe II, 3 ph. / 50 Hz, protection to IP 54, temperature class T3 725 17190 0.55 400 2.20 32 470 40 81 AVD DK 800/8 Ex/.. 5326 AVD RK 800/8 Ex/.. 6974 135 not permitted 950 20340 0.95 400 2.70 23 470 40 90 AVD DK 800/6 Ex/.. 5329 AVD RK 800/6 Ex/.. 6976 135 not permitted 950 26710 1.90 400 4.70 35 470 40 118 AVD DK 800/6 Ex/.. 5330 AVD RK 800/6 Ex/.. 6977 210 not permitted 1450 31900 3.60 400/690 8.10 24 498 40 115 AVD DK 800/4 Ex/.. 5332 AVD RK 800/4 Ex/.. 6978 210 not permitted 1450 36820 5.00 400/690 10.00 30 498 40 143 AVD DK 800/4 Ex/.. 5333 AVD RK 800/4 Ex/.. 6979 290 not permitted
1) Dahlander-windings
2) Separate windings Full motor protection unit:
3) MSA, Ref. No. 1289
4) M4, Ref. No. 1571
5) Includes a full motor protection unit
6) alternative: TSD; 5 step transformer controll e without motor protection unit

98

ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
pdf-page pdf ae En 2008-12-49-01