TecCrete ® Data Center Flooring
Open the catalog to page 1The TecCrete Data Center product is based on Haworth’s proven TecCrete access flooring platform. For the last 30 years, it has been the leading choice for architects and developers who prefer a top-quality access flooring system with best-in-class features. Haworth, a family owned manufacturer based in Michigan since 1948, is committed to making TecCrete products in the USA. Tec C r et e Data Center Haworth has built on TecCrete’s legendary performance and durability by adding technology-friendly surface finishes and high-efficiency airflow panels to create the TecCrete Data Center, an advanced...
Open the catalog to page 2-- T ec C r e t e PER FO R MAN CE Product Static Loading Rating Dynamic Load Rating System Panel Understructure Concentrated Uniform Ultimate Rolling 10-Pass Rolling 10,000-Pass 1250 1 1/8” Panel Cornerlock 1250 lbs 600 lbs 1800 lbs 1200 lbs 800 lbs 1500 1 1/8” Panel Stringer 1500 lbs 700 lbs 2500 lbs 1500 lbs 1250 lbs 2000 1 1/2” Panel Stringer 2000 lbs 800 lbs 2800 lbs 1500 lbs 1250 lbs 2500 1 1/2” Panel HD Stringer 2500 lbs 900 lbs 3100 lbs 2000 lbs 2000 lbs Standard Duty panel for everyday applications. 1.125” Heavy Duty panel for heavier load requirements. 1.5” P ed esta ls fo r sta n da...
Open the catalog to page 3-- Engineered for reliability, safety, and installation ease T ec C r e t e PER FO R MAN CE Proprietary Concrete and Steel Composite Design Product Static Loading Rating Panel Understructure Concentrated Uniform Ultimate 1250 1 1/8” Panel Cornerlock 1250 lbs 600 lbs 1800 lbs 1200 lbs 800 lbs 1500 1 1/8” Panel Stringer 1500 lbs 700 lbs 2500 lbs 1500 lbs 1250 lbs 2000 1 1/2” Panel Stringer 2000 lbs 800 lbs 2800 lbs 1500 lbs 1250 lbs 2500 1 1/2” Panel HD Stringer 2500 lbs 900 lbs 3100 lbs 2000 lbs 2000 lbs Standard Duty panel for everyday applications. • olid 1 1/8” or 1 1/2” thick throughout S...
Open the catalog to page 4AIrflow panel options for all applications Th e Hawo rth T ec C r e t e data center coo li n g advantag e 56% open area Triad™ Chamfer Airflow panel features patented airflow enhancement technology. • Steel design offers heavy-duty load capacity. • ulti-directional fins under panel increases airflow over M flat-bottom grates. 56% open Triad Chamfer • igher cooling plume allows cold air to H reach entire height of rack. Airflow panel. • pper server temperatures can be U reduced 10 – 20 degrees Fahrenheit. 25% open area perforated panels Airflow fins • verall cooling requirements may be O reduced...
Open the catalog to page 5AIrflow panel options for all applications Th e Hawo rth T ec C r e t e data center coo li n g advantag e 56% open area Triad™ Chamfer Airflow panel features patented airflow enhancement technology. T ec C r e t e I nteg r al Ai r S e als Only TecCrete Data Center panels have the option of an integral air seal attached directly to the panel side. • Steel design offers heavy-duty load capacity. • ulti-directional fins under panel increases airflow over M flat-bottom grates. 56% open Triad Chamfer • igher cooling plume allows cold air to H reach entire height of rack. Airflow panel. • pper server...
Open the catalog to page 6Surface Finish Systems Bare crete engineered for the Long Run data center and Supported by the Industry’s Longest Standard Warranty Against Delamination T ec C r e t e Data Center TecCrete Bare—the latest in finishing technology • nly TecCrete access floor can be used O bare with field applied Electraseal ESD or Electra-guard conductive coatings. • urable bare finish eliminates the hassle D and expense resulting from cracking, chipping or delamination of high pressure laminate. • are tiles can be secured using B cornerlock screws to eliminate the use of stringers, saving both time and expense....
Open the catalog to page 7product summary Solid panel system options: • TecCrete 1250 without stringer • TecCrete 1500 with stringer • TecCrete 1500sl without stringer • TecCrete 2000 with stringer • TecCrete 2500 with stringer Solid panel finish options: • Field-applied acrylic surface finish • Field-applied Electraseal™ ESD finish • Field-applied Electraguard conductive finish • actory-applied 1/16” or 1/8” anti-static or conductive F high-pressure laminate with TecTrim™ edge • Factory-applied conductive vinyl with captured trim 25% airflow panel finish options: • Factory applied 1/16” or 1/8” antistatic or conductive...
Open the catalog to page 8For more information call 800.344.2600 or 616.393.3000. Download additional copies at haworth.com This brochure is printed on FSC® certified U2®:XG™ paper, manufactured with electricity in the form of renewable energy (wind, hydro, biogas) and contains a minimum of 30% post-consumer recovered fiber. FSC is a global benchmark for responsible forest management. Haworth is a registered trademark of Haworth, Inc. Printed in USA ©Haworth, Inc 2011 12.11 Item #0724 Haworth.com | Haworth-Europe.com | Haworth-Asia.com
Open the catalog to page 92 Pages
290 Pages
7 Pages
5 Pages
7 Pages
6 Pages
16 Pages
18 Pages
6 Pages
4 Pages
2 Pages
42 Pages
2 Pages
2 Pages
2 Pages
5 Pages
4 Pages
2 Pages
2 Pages
4 Pages
3 Pages
4 Pages
52 Pages
11 Pages
4 Pages
8 Pages
2 Pages
2 Pages
2 Pages
9 Pages
2 Pages
7 Pages
6 Pages
2 Pages
2 Pages
5 Pages
2 Pages
1 Page
2 Pages
2 Pages
5 Pages
3 Pages
44 Pages
20 Pages
2 Pages
15 Pages
16 Pages
4 Pages
2 Pages
2 Pages
5 Pages
7 Pages
9 Pages
2 Pages
9 Pages
14 Pages
9 Pages
10 Pages
2 Pages
2 Pages
2 Pages
2 Pages
5 Pages
29 Pages
385 Pages
8 Pages
24 Pages
7 Pages
28 Pages
24 Pages
20 Pages
52 Pages
20 Pages
32 Pages
11 Pages
8 Pages
16 Pages
16 Pages
12 Pages
10 Pages
14 Pages
10 Pages
9 Pages
4 Pages
5 Pages
2 Pages
2 Pages
2 Pages
16 Pages
2 Pages
26 Pages
14 Pages
2 Pages
2 Pages
2 Pages
2 Pages
19 Pages
11 Pages
15 Pages
2 Pages
5 Pages
2 Pages
18 Pages
3 Pages
2 Pages
10 Pages
2 Pages
2 Pages
16 Pages
2 Pages
9 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
10 Pages
4 Pages
7 Pages
14 Pages
2 Pages
5 Pages
8 Pages
7 Pages
7 Pages
20 Pages
19 Pages
18 Pages
55 Pages