C80/1, C90, C150SensorC150VKK, C260Power unitC105S Logix Fenix
(SACF10)
Type For heaters Functions
° C- Temperature adjustment range +(40–110) >
Times
C80/1Separate sensor included230 V 1N~max 8 kWC90Separate sensor included
400 V 3 N~max 9 kWC150Separate sensor included400 V 3 N~max 15 kWC150VKKSeparate sensor included
400 V 3 N~max 15 kWC260Control unit, 2-group power
unit and separate sensor
included
400 V 3 N~16A, max 22 kW25A, max 34 kWKA3(optional)C105S LogixControl unit and two sensors
400 V 3 N~max 10,5 kW(K15GS, max 15,5 kW)
Fenix400 V 3 N~SACF10 wireless control unitfor controlling power units.SACF150 power unit forcontrolling heatersSACF165S power unit forcontrolling Combi heater orheater and separate steamerSACF100 power unit forcontrolling colour light JM20E–JM30E (2–3 kW)D23E–D36E (2,3–3,6 kW)
KV30E–KV80E (3–8 kW)
M45E–M80E (4,5–8 kW)
HH6 (6 kW)JM20E–JM30E (2–3 kW)D23E–D36E (2,3–3,6 kW)KV30E–KV80E (3–8 kW)M45E–M90E (4,5–9 kW)
HH6–HH9 (6–9 kW)JM20E–JM30E (2–3 kW)D23E–D36E (2,3–3,6 kW)
KV30E–KV80E (3–8 kW)
M45E–M90E (4,5–9 kW)T9–T10,5 (9–10,5 kW)HH6–HH12 (6–12 kW)
F10,5–F15 (10,5–15 kW)
K11G–K15G (11–15 kW)JM20E–JM30E (2–3 kW)D23E–D36E (2,3–3,6 kW)
KV30E–KV80E (3–8 kW)
M45E–M90E (4,5–9 kW)T9–T10,5 (9–10,5 kW)HH6–HH12 (6–12 kW)
F10,5–F15 (1O,5–15 kW)
K11G–K15G (11–15 kW)F16,5–F18 (16,5–18 kW)K11G–K15G (11–15 kW)L20–L33 (20–33 kW)
D29S (2,9 kW)KV50SE/A–KV90SE/A (5–9 kW)
T7C/A–T9C/A (7–9 kW)
K11GS–K15GS (10,3–15,5 kW)
JM20E–JM30E (2–3 kW)D23E–D36E (2,3–3,6 kW)KV30E–KV80E (3–8 kW)
M45E–M90E (4,5–9 kW)
HH6–HH9 (6–9 kW)
T9–T10,5 (9–10,5 kW)F10,5 (10,5 kW)SS20/A Digital control unit
- Digital temperature display, max. +125 ° CDigital control unit- Digital temperature display, max. +125 - Operating 4 h(alternatively 6 or 12 h)- Pre-setting time 0–12 h- Operating 4 h(alternatively 6 or 12 h)- Pre-setting time 0–12 h- Operating 4 h(alternatively 6 or 12 h)- Pre-setting time 0–12 h- Operating 12 h(alternatively 6 or 18 h)- In manual operation, the operatingtime is 0–12 h at half-hour intervals- Operating 12 h(alternatively 6 or 18 h)- In manual operation, the operatingtime is 0–12 h at half-hour intervals- Can be modified for 3-shift use- Operating 4 h (adjustable)- Pre-setting time 0–12 h ° C- Temperature adjustment range +(40–110) >
25070 ° CDigital control unit- Digital temperature display, max. +125 >
3+1h - + 223 ° C- Temperature adjustment range +(40–110) ° CDigital control unit- Digital temperature display, max. +125 >
Sensor
Power unit
51 ° C- Temperature adjustment range +(40–110) ° C- Week timer and remote control functionDigital control unit, 2-group power unit- Digital temperature display, max. +125 >
73 ° C- Temperature adjustment range +(40–110) >
27 ° C- Week timer and remote control functionCover with a
lock furniture for control unitsC150, C150VKK and C260Digital control unit- Digital temperature display, max. +125 ° C- Temperature adjustment range +(40–110) >
350 ° C- Heater control
- Steamer control, RH 10–95%
- Combined heater and steamer control >
280112 SACF10
SACF150, SACF165SSACF100
39 102 - User-prompting touch
screen furniture.
- Features to control:
- temperature - humidity -
lights
- colour lights
- ventilation
- week timer - adjustable operating time
- adjustable pre-setting time >
155 SACF150 power unit for controlling
same heaters as C150 control unit.SACF165S power unit for controllingsame heaters as C105S control unitand also following models:HH12 (12 kW)
F15 (15 kW)
K11G –K15G (11 –15 kW) >
350 66 205 321 66 145