ULE Supply air valve for wall installation Supply air valve for wall installation with adjustable operations Flow pattern selection and pressure loss adjustment by front plate Airflow rate measurement and adjustment facility Detacable front plate
Open the catalog to page 1PART MATERIAL NOTE Collar Steel Front plate Steel Gasket Rubber combound Painted Finishing Special colour available White RAL 9010
Open the catalog to page 3The supply air flow is directed slightly towards the ceiling. The throw length is adjusted by turning the adjustment screw open or closed.
Open the catalog to page 4ULE is installed to the duct with finger screws from inside the valve. The front plate is mounted and the correct adjustment position selected. A plastic plug is fitted to cover the adjustment screw.
Open the catalog to page 5ADJUSTMENT Front plate position (A) is set with a adjustment screw. The volume flow rate is determined by setting a probe inside the devicev and reading the pressure difference between the probe and room. The airflow rate is calculated with the formula.
Open the catalog to page 6When the adjustment has been made, cover the screw with the plastic plug.
Open the catalog to page 7CODE DESCRIPTION 1 Cover plug 2 Adjustment screw 3 Front plate 4 Fixing screw 5 Collar For cleaning check first the adjustment position and remove the plastic plug and detach the front plate from the collar by opening the adjustment screw. Remove the collar by loosening the fixing screws and clean the components with damp cloth. They must not be immersed in water. Reassemble the valve in reverse order.
Open the catalog to page 8SUGGESTED SPECIFICATION ULE supply air valve shall have a detachable front plate and collar made of painted steel with a white (RAL 9010) standard colour. The collar shall have a screw fastening and incorporate a sealing gasket. Supply airflow rate and throw length shall be adjusted by turning the adjustment screw in the front plate. Pressure loss shall be selected at the same time as the flow pattern adjustment and balancing.
Open the catalog to page 9PRODUCT CODE ULE-D D = Connection size 100, 125 Specific CO = Colour W White (RAL 9010) X Special colour Code examble ULE-100, CO=W
Open the catalog to page 10All HALTON catalogs and technical brochures
-
Halton Vita Cell Room (VCR)
2 Pages
-
Halton Rex Expander (RXP)
16 Pages
-
Halton CBD
8 Pages
-
FS Halton AHUs
28 Pages
-
Halton KCD
3 Pages
-
KVE-CM
7 Pages
-
KMC - MobiChef
5 Pages
-
Halton MobiChef
12 Pages
-
R6B
9 Pages
-
Halton Vario
20 Pages
-
Halton FDS
7 Pages
-
Halton FDR
6 Pages
-
Halton FDI
6 Pages
-
Halton FDE
8 Pages
-
Halton FDC
5 Pages
-
ALE/ALU
8 Pages
-
AHF
5 Pages
-
JTH
4 Pages
-
FDC
5 Pages
-
AFB
7 Pages
-
TCG 2013
4 Pages
-
FCU 2013
6 Pages
-
HFB - Airflow Management Damper
17 Pages
-
VHB - Active VAV Diffuser
7 Pages
-
TLD - Wall Diffuser Unit
9 Pages
-
FDB2 -
4 Pages
-
CPA - Passive Chilled Beam
13 Pages
Archived catalogs
-
FCU Vertical Fancoil Unit
4 Pages
-
Halton ? AdaptableClimate
12 Pages
-
Halton ? Ventilation fire safety
12 Pages
-
Halton ? Chilled Beams
12 Pages
-
HALTON-POLLUSTOP
4 Pages
-
UNIPOINT
4 Pages
-
HALTON-KVD
6 Pages
-
HALTON-KCE
10 Pages
-
HALTON-KSK
6 Pages
-
KCJ
12 Pages
-
Halton - universal grilles
46 Pages
-
Halton - beam design guide
31 Pages