R6B - 1

Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is:   A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces where demand based ventilation, individual control and flexibility are not required. Product models & accessories  Model with combined cooling and heating exchanger

Open the catalog to page 1
R6B - 2

Integration with suspended ceiling Enabling Wellbeing

Open the catalog to page 2
R6B - 3

Material Part The Halton Rex 600 Basic's cooling/heating water pipe connections are Cu15/Cu10 with wall thickness of 0.9-1.0 mm fulfilling European Standard EN 1057:1996. The maximum chilled/hot water circuit operating pressure is 1.0 MPa. The supply air duct connection is 125 mm. Enabling Wellbeing

Open the catalog to page 3
R6B - 4

The Halton Rex 600 Basic chilled beam is designed to be installed flush with a suspended ceiling. The primary supply air enters the plenum of the active chilled beam. From there the air is diffused into the room through nozzles. The supply air nozzle jets efficiently induce ambient room air, which is then directed horizontally along the ceiling surface. The secondary air is drawn through the perforation located at the bottom of the beam. The air then cycled throu

Open the catalog to page 4
R6B - 5

Installation The Halton Rex 600 Basic active chilled beam is especially suitable for ceiling mounting running parallel to the exterior wall of the room. The chilled beam can be attached directly to the ceiling surface (H1 = 195 mm) or suspended using threaded drop rods (8 mm). Each beam is equipped with movable brackets fixed to both sides of the beam. It is recommended that the brackets be positioned one quarter of the unit length (L/4) away from the end of the beam. Install the main pipelines of the cooling and heating water circuits above the level of the chilled beam in order to enable...

Open the catalog to page 5
R6B - 6

Cooling The recommended cooling water mass flow rate is 0.02-0.10 kg/s, resulting in a temperature rise of 1-4 °C in the heat exchanger. To avoid condensation, the recommended inlet water temperature of the heat exchanger is over 14 °C Heating The recommended heating water mass flow rate is 0.01-0.04 kg/s, resulting in a temperature drop of 5-15 °C in the heat exchanger. The maximum recommended temperature of the inlet water for the heat exchanger is 35 °C. Balancing and control of water flow rates Balance the water flow rates of the Halton Rex 600 Basic chilled beam with adjustment valves...

Open the catalog to page 6
R6B - 7

Front panel Casing Supply air connection Heat exchanger Open the front panel (1) of the chilled beam. In Clean the supply air plenum and fins of the beams longer than 2400 mm, the front panel can heat exchanger (4) with a vacuum cleaner, taking care not to damage the fins. Clean the front panel and other visible painted plates using a damp cloth.

Open the catalog to page 7
R6B - 8

Technical specification The active chilled beam shall have an integral The fins shall be manufactured from aluminium. recirculation air path through the perforated front panel. Optionally, heating shall be incorporated within The front panel shall be openable from either side the heat exchanger by means of two 10-mm in order to allow general maintenance and pipes, connected in series. All joints shall be soldered and factory pressure- The front panel shall be removable without any special tools. The pipework s maximum operation pressure is The active chilled beam shall be 595 mm wide and...

Open the catalog to page 8
R6B - 9

Product code R6B-S-L S = Nozzle type A Bi-directional/ Nozzle 1 B Bi-directional/ Nozzle 2 C Bi-directional/ Nozzle 3 D Bi-directional/ Nozzle 4 E Bi-directional/ Nozzle 5 L = Total length 1200, 1800, 2400, 3000 Other options and accessories LD = Duct connection / Duct size / Damper L2N Left / 125 / Without damper TC = Cooling / Heating functions (Coil type) C Cooling H Cooling and Heating CO = Colour W White ( RAL 9010/20% gloss) ZT = Tailored product N No Code example R6B-A-3000, LD=L2N,TC=C,CO=W, ZT=N

Open the catalog to page 9

All HALTON catalogs and technical brochures

  1. Halton CBD

    8 Pages

  2. FS Halton AHUs

    28 Pages

  3. Halton KCD

    3 Pages

  4. KVE-CM

    7 Pages

  5. Halton Vario

    20 Pages

  6. Halton FDS

    7 Pages

  7. Halton FDR

    6 Pages

  8. Halton FDI

    6 Pages

  9. Halton FDE

    8 Pages

  10. Halton FDC

    5 Pages

  11. ALE/ALU

    8 Pages

  12. AHF

    5 Pages

  13. JTH

    4 Pages

  14. FDC

    5 Pages

  15. AFB

    7 Pages

  16. TCG 2013

    4 Pages

  17. FCU 2013

    6 Pages

  18. FDB2 -

    4 Pages

Archived catalogs

  1. UNIPOINT

    4 Pages

  2. HALTON-KVD

    6 Pages

  3. HALTON-KCE

    10 Pages

  4. HALTON-KSK

    6 Pages

  5. KCJ

    12 Pages