Open the catalog to page 1Safety of the built environment is a crucial factor on land and sea. Halton’s leading fire safety solutions ensure protection in buildings, on board ships and in extreme working conditions, such as on offshore platforms and in industries, where people’s lives are at risk unless necessary precautions are taken. 2
Open the catalog to page 2Ensuring ventilation fire safety Fire and smoke pose a significant threat in the built environment. Ventilation fire safety solutions are primarily designed to protect people and to ensure their safety in case of fire. However, adequate precautions will also protect the building structure. Halton fire safety solutions are widely used, from the most demanding industrial applications to commercial and institutional buildings around the world. Solutions that comply with British and European standards. In the European Union member countries, fire dampers must be tested according to the EN...
Open the catalog to page 3Fire operation (J) Fire damper open Fire damper range: Insulated EIS 60-120 fire dampers • Halton FDI for circular ducts (EIS 60) • Halton FDR for rectangular ducts (EIS 120) • Halton FDC for circular ducts (EIS 120) Non-insulated ES 90/60 fire and smoke dampers • Halton FDE for circular ducts (ES 90) • Halton FDS for rectangular ducts (ES 60) Fire damper management system range MSH: • Unit for 8 or 16 fire dampers • Unit with smoke detector operation Fire valves: • Halton FRH, compliant with
Open the catalog to page 4re safety solutions - compartmentation Fire dampers are located in each fire compartment wall or ceiling to prevent the spread of heat and fire from one compartment to another through the ventilation system. As a basic rule, the ventilation system must not impair the fire safety provided by the building structure. Accordingly, the fire dampers are usually selected to meet the fire resistance period of the fire compartment-separating element. The fire dampers are classified for tightness (E), insulation (I), smoke tightness (S) and fire resistance in minutes. Fire damper operation. The fire...
Open the catalog to page 5Normal operation Smoke damper open Fire (smoke) operation Smoke damper closed SDI SDE SDS MSH Smoke damper range: Non-insulated ES 60 and ES 90 smoke damper Insulated EIS 60 smoke damper • Halton SDS for rectangular ducts • Halton SDI for circular ducts (EIS 60) Smoke damper management system range MSH: Non-insulated ES 90 smoke damper • Unit for 8 or 16 fire dampers • Halton SDE for circular ducts • Unit with smoke detector operation 6
Open the catalog to page 6imiting the spread of smoke It is smoke, not fire that causes the most casualties. Toxic smoke can cause unconsciousness in only a few minutes. And even if injuries to people are avoided, smoke is likely to cause major financial losses by damaging property. Afterwards, the rebuilding period may also lead to loss of business. Therefore smoke must be efficiently prevented from spreading - and therefore the new standards and revised building codes place great emphasis on smoke management. The smoke dampers are equipped with electrical spring return actuators configured for safety position -...
Open the catalog to page 7Normal operation Compartment in fire Smoke exhaust fan off Damper closed Smoke exhaust fan on Damper open EDE EDS Smoke exhaust damper range: • Halton EDE for circular ducts • Halton EDS for rectangular ducts 8
Open the catalog to page 8moke Exhaust Solutions A burning building creates a lot of heat, smoke and toxic fire gases. They all reduce visibility, make exhaust and fire fighting more difficult, and increase the risk of combustion and fire stress to the building structures. In order to secure personal safety, effective fire fighting and minimal damages to structures and property, the developing smoke must be extracted during the early stages of the fire. The key tasks for the smoke exhaust system are ensuring that people find their evacuation routes and facilitating the evacuation itself by keeping the routes free...
Open the catalog to page 9Reliable fire safety made easy Choose Halton as your fire safety partner. To meet the highest standards, all Halton products are tested to the finest detail and comply with the latest British BS and European EN standards To ensure top quality and full environmental responsibility, Halton complies with ISO 9001 and 14001 quality systems. The product and production quality is annually inspected byVTT. Solutions for all fire and smoke safety applications. Halton offers a full range of fire dampers, smoke dampers and smoke exhaust dampers together with a fire damper management system and...
Open the catalog to page 10to match all installation cases as delivered, they simplify the design, purchasing and installation processes considerably. Similarly, Halton's pricing structure is simple and transparent, as additional installation accessories are not required. Motorized and manual systems. Fire and smoke dampers can be equipped with an actuator for testing the system. The status of the dampers is also available to the building management system to ensure proper operation of the ventilation With increasing emphasis on smoke safety, the share of motorized fire and smoke dampers is increasing. Earliest...
Open the catalog to page 11All HALTON catalogs and technical brochures
-
Halton Vita Cell Room (VCR)
2 Pages
-
Halton Rex Expander (RXP)
16 Pages
-
Halton CBD
8 Pages
-
FS Halton AHUs
28 Pages
-
Halton KCD
3 Pages
-
KVE-CM
7 Pages
-
KMC - MobiChef
5 Pages
-
Halton MobiChef
12 Pages
-
R6B
9 Pages
-
Halton Vario
20 Pages
-
Halton FDS
7 Pages
-
Halton FDR
6 Pages
-
Halton FDI
6 Pages
-
Halton FDE
8 Pages
-
Halton FDC
5 Pages
-
ALE/ALU
8 Pages
-
AHF
5 Pages
-
JTH
4 Pages
-
FDC
5 Pages
-
AFB
7 Pages
-
TCG 2013
4 Pages
-
FCU 2013
6 Pages
-
HFB - Airflow Management Damper
17 Pages
-
VHB - Active VAV Diffuser
7 Pages
-
TLD - Wall Diffuser Unit
9 Pages
-
FDB2 -
4 Pages
-
CPA - Passive Chilled Beam
13 Pages
Archived catalogs
-
FCU Vertical Fancoil Unit
4 Pages
-
Halton ? AdaptableClimate
12 Pages
-
Halton ? Chilled Beams
12 Pages
-
HALTON-POLLUSTOP
4 Pages
-
UNIPOINT
4 Pages
-
HALTON-KVD
6 Pages
-
HALTON-KCE
10 Pages
-
HALTON-KSK
6 Pages
-
KCJ
12 Pages
-
Halton - universal grilles
46 Pages
-
Halton - beam design guide
31 Pages