video corpo

CCC - Adaptable Active Chilled Beam
13Pages

{{requestButtons}}

Catalog excerpts

CCC - Adaptable Active Chilled Beam - 1

CCC Adaptable Active Chilled Beam • Combined cooling, heating, and supply air unit for • Manual adjustment or demand-based control of flush installation within a suspended ceiling supply air flow rate; demand-based operation using • Well suited for spaces with high cooling loads, low air flow damper in constant-pressure ductwork zone humidity load, and variable ventilation requirements • Ideal solution for applications where high-quality • Additional air flow rate has no effect on cooling/ environmental conditions, demand-based ventilation, heating capacities in the constant-pressure ductwork and individual room control are appreciated • Typical applications: office rooms, landscape offices, meeting rooms, team rooms, patient care rooms, Product Models & Accessories etc. • Model with combined cooling and heating coil, or • Enhanced life-cycle performance with low air and model with electric heating foil water flow rates • Model with manual or motorised Halton Air Quality In-built flexibility for easy and fast adaptation of (HAQ) control or with reservation for retrofitting operation during space layout and usage changes • Individually adjustable velocity conditions with • Model with air flow adjustment damper Halton Velocity Control (HVC) • Model with integrated exhaust valve • Model with direct light fittings • In-built flexibility of partition wall relocations with • Model adapted to Dampa ceiling installation Halton Velocity Control • Individually adjustable supply air flow rate for changes in layout or space usage, with Halton Air Quality (HAQ) control CCC - Adaptable Active Chilled Beam 450

Open the catalog to page 1
CCC - Adaptable Active Chilled Beam - 2

Performance values are presented for operation with HVC in position 3. If Lmin will be > 5 m then use HVC The impact of HVC compared to presented values in average: position 2: -15% of Pw and Position 1: -35 % of Pw Leff Effective length, length of cooling coil, mm Pa Supply air capacity, W Pw Coil capacity, W NZ Nozzle type DPtot Chilled beam chamber pressure, Pa Lmin Minimum distance between central lines of two supply units, m Ld Distance where supply air jet detaches from the ceiling, m Qv-Aq HAQ diffuser air flow, l/s Pt Total cooling power with HAQ Room temperature (Tr) Chilled water...

Open the catalog to page 2
CCC - Adaptable Active Chilled Beam - 3

Coil length Cooling/heating water pipe connections are Cu15/ The supply air duct connection is 125 mm. Cu10 with wall thickness of 1.0 mm fulfilling European Standard EN 1057:1996. The electric heating foil system fulfils EN 60335-1 The maximum chilled/hot water circuit operating Class I standards. ccc - Adaptable Active Chilled Beam

Open the catalog to page 3
CCC - Adaptable Active Chilled Beam - 4

Model with direct light fittings Exhaust valve integration PRODUCT MODELS AND ACCESSORIES ACCESSORY MODEL Combined cooling and heating coil Coil with hot water circulation Cooling/heating copper water pipe connections are Ø 15/10 mm Electric heating Electric foil for heating Airflow adjustment damper Removable through access panel Halton Air Quality control (HAQ damper) Manual operation HAQ takes 300 mm of the total beam length, decreasing the effective beam length. Motorised operation. Power supply: 24 VAC. Control signal: 0 ... 10 VDC. In retrofitting, motorisation of HAQ is possible HAQ...

Open the catalog to page 4
CCC - Adaptable Active Chilled Beam - 5

Function The CCC chilled beam is designed to be installed flush Velocity control in the occupied zone with a suspended ceiling. Halton Velocity Control (HVC) is used for adjusting The primary supply air enters the plenum of the active room air velocity conditions either when room layout chilled beam. From there it is diffused into the room is changed (e.g., in cases where the partition wall through nozzles and supply slots located at the bottom is located near the chilled beam) or when local, individual velocity conditions need to be altered. HVC The supply air nozzle jets efficiently...

Open the catalog to page 5
CCC - Adaptable Active Chilled Beam - 6

The Halton Air Quality control unit’s position and the selection of chilled beam nozzle size allow adjustment of the primary air flow rate in the space. The air flow adjustment damper (MSM) can be used for balancing air flow. A detachable adjustment module allows access for cleaning of ductwork. When a motorised air quality control (HAQ) unit is used, the maximum and minimum air flow rates are adjusted with the stroke limiters of the damper. The air Airflow rate control flow adjustment damper (MSM) is not recommended The supply air flow of the chilled beam nozzle jets are for use in...

Open the catalog to page 6
CCC - Adaptable Active Chilled Beam - 7

Light distribution curves The chilled beams with luminaires are equipped with optics suitable for working with monitors. Delivery includes the luminaires with fluorescent lamps installed. The connecting cable with a plug can be delivered factory-installed upon request. The luminaires are delivered with either standard or dimmable electronic ballasts. Luminaire properties Ballast electronic electronic electronic Wiring diagram 1. Connection with standard electronic ballast (HF) 2.Connection with dimmable electronic ballast (HFR) ccc - Adaptable Active Chilled Beam

Open the catalog to page 7
CCC - Adaptable Active Chilled Beam - 8

CCC with exhaust valve Luminaire type Luminaire type Luminaire length Luminaire length Coil length Coil length Total beam length One-piece mm Total beam length One-piece mm CCC - Adaptable Active Chilled Beam 457 Number of luminaires in a chilled beam

Open the catalog to page 8
CCC - Adaptable Active Chilled Beam - 9

Duct installation of the exhaust valve Replacing manual HAQ with motorised HAQ Electric heating foil Duct installation of the exhaust valve Note: URH + S is not possible The CCC active chilled beam is suitable for ceiling mounting running along the long or short side of a room. In selection of the beam orientation, the location of the supply air and water circuit connections should be taken into account. The beam can be attached directly to the ceiling surface (H1 = 220 mm) or suspended using threaded drop rods (8 mm). Each beam is equipped with movable brackets fixed to both sides of the...

Open the catalog to page 9
CCC - Adaptable Active Chilled Beam - 10

Adjustment Nozzle jet airflow rate qv1 Cooling The recommended cooling water mass flow rate is 0.02-0.10 kg/s, resulting in a temperature rise of 1-4 °C in the heat exchanger. To avoid condensation, the recommended inlet water temperature of the heat measured static chamber pressure, Pa The recommended heating water mass flow rate is 0.01-0.04 kg/s, resulting in a temperature drop of The maximum temperature of the inlet water for the heat exchanger is 35 °C. The supply air flow rate of the Halton Air Quality Balancing and control of water flow rates control unit is determined by measuring...

Open the catalog to page 10

All HALTON catalogs and technical brochures

  1. Halton CBD

    8 Pages

  2. FS Halton AHUs

    28 Pages

  3. Halton KCD

    3 Pages

  4. KVE-CM

    7 Pages

  5. R6B

    9 Pages

  6. Halton Vario

    20 Pages

  7. Halton FDS

    7 Pages

  8. Halton FDR

    6 Pages

  9. Halton FDI

    6 Pages

  10. Halton FDE

    8 Pages

  11. Halton FDC

    5 Pages

  12. ALE/ALU

    8 Pages

  13. AHF

    5 Pages

  14. JTH

    4 Pages

  15. FDC

    5 Pages

  16. AFB

    7 Pages

  17. TCG 2013

    4 Pages

  18. FCU 2013

    6 Pages

  19. FDB2 -

    4 Pages

Archived catalogs

  1. UNIPOINT

    4 Pages

  2. HALTON-KVD

    6 Pages

  3. HALTON-KCE

    10 Pages

  4. HALTON-KSK

    6 Pages

  5. KCJ

    12 Pages