SOUND INSULATION - 44 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

  11. P. 20

  12. P. 30

  13. P. 40

Catalogue excerpts

SOUND INSULATION For sound absorption in reinforced concrete stairs and landings Thermal insulation Sound insulation

 Open the catalogue to page 1

SOUND INSULATION OUR CONVICTION: FORWARD CONSTRUCTING. Not just to reflect the current state of building technology, but always to be a decisive step ahead – this is our promise. This is why we constantly achieve pioneering work in all product areas. Our employees consistently use their extensive practical experience and creativity to benefit our customers. Through regular collaborative dialogue with our target groups, we develop today the products which are needed tomorrow. With our dynamics we set consistently milestones in building technology – yesterday, today and tomorrow. This is what we...

 Open the catalogue to page 2

SOUND INSULATION CONTENT 04  Sound insulation For sound absorption in reinforced concrete stairs and landings For straight and spiral flights of stairs 36  Impact sound plate type TSP For stair stringers and stair landings We are always there for you. We will be wherever you are.

 Open the catalogue to page 3

SOUND INSULATION TYPE OVERVIEW SCHALL-ISOBOX® TYPE TSB-F PAGE 10 Impact sound insulation element for prefabricated stair landings. Stair landing - wall SCHALL-ISOBOX® TYPE TSB-M+B PAGE 12 Impact sound insulation element for in-situ concrete stair landings. Stair landing - wall SCHALL-ISOBOX® TYPE TSB-T PAGE 14 Impact sound insulation element with reinforcement cage for stair landings. Stair landing - wall SCHALL-ISOBOX® TYPE TSB-BT PAGE 16 Impact sound insulation element with supporting element for stair landings. Stair landing - wall SCHALL-ISODORN TYPE HQW PAGE 18 Impact sound insulation element...

 Open the catalogue to page 4

SOUND INSULATION TYPE OVERVIEW SCHALL-ISOSTEP® TYPE HT-V PAGE 26 Impact sound insulation element for sound absorption in flights of stairs. Flight of stairs - stair landing SCHALL-ISOTRITT® TYPE Z PAGE 30 Impact sound insulation element for sound absorption in prefabricated staircases. Flight of stairs - stair landing SCHALL-ISOTRITT® TYPE ZB PAGE 30 Impact sound insulation element for sound absorption in prefabricated staircases. Flight of stairs - base plate IMPACT SOUND PLATE TYPE TSP PAGE 36 Impact sound plate for stair stringers and stair landings. Staircase - wall

 Open the catalogue to page 5

SCHALL-ISOBOX® type TSB Impact sound reduction ≥ Lw*=23 dB IMPACT SOUND BOX FOR STAIR LANDINGS APPLICATION AREA The SCHALL-ISOBOX® TSB is used to isolate the impact sound generated in staircases between stair landings and staircase walls so that it is not transferred into living or working areas. The SCHALL-ISOBOX® is made of polyethylene with integrated elastomeric bearings to transfer the load. Depending on the design, positive and/or negative shearing and horizontal forces can be transferred. ▪▪ Type-tested ▪▪ Considerable impact sound reduction ▪▪ R90 fire safety inspection report ▪▪ Simple...

 Open the catalogue to page 6

On-site edge insulation strips e.g. TSP impact sound plate SCHALL-ISOBOX type TSB-MB In-situ concrete landing On-site bracket reinforcement as per structural analysis Avoid sound bridging problems Elastomer bearing PRODUCT VERSIONS/TYPE DESIGNATIONS On-site edge insulation strips e.g. TSP impact sound plate SCHALL-ISOBOX type TSB-MB On-site edge insulation strips e.g. TSP impact sound plate In-situ concrete landing SCHALL-ISOBOX type TSB-MB On-site edge insulation strips e.g. TSP impact sound plate SCHALL-ISOBOX® type TSB-F Avoid sound bridging problems On-site bracket reinforcement as per structural...

 Open the catalogue to page 7

TECHNICAL BASICS & DIMENSIONING TABLE SCHALL-ISOBOX® TYPE DESIGNATION TSB MB 12 = lower bearing / = lower & upper bearings / = lower, upper & side bearings MB = brick + concrete / F = prefabricated part / BT = concrete supporting element / T = reinforcement cage TSB = impact sound box SCHALL-ISOBOX® DIMENSIONS Lower, upper & side bearings Lower & upper bearings SOUND INSULATION Elastomer bearing as per DIN 4141 and building control approval Bearing load Sound absorption * see test report from the Fraunhofer Institute for Building Physics FIRE PROTECTION SCHALL-ISOBOX® product versions TSB T/TSB...

 Open the catalogue to page 8

ARRANGEMENT OF THE ELEMENTS NOTES It is recommended that the landings are supported at four points using ISOBOX® elements. The SCHALL-ISOBOX® may, of course, be arranged differently for specific staircase or landing types. SUGGESTED ARRANGEMENT FOR SCHALL-ISOBOX® TYPE TSB - FLOOR PLAN Stair landing Stair landing TSP PL peripheral impact sound plate Flight of stairs and landings Support on opposite sides of the landing Stair landing Stair landing TSP PL peripheral impact sound plate Flight of stairs and landings Support on opposite side and adjacent side of the landing

 Open the catalogue to page 9

TSB-F PRODUCT VERSION APPLICATION Isolation of the impact sound generated in prefabricated landings and staircase walls SYSTEM COMPONENTS RATED VALUES FOR CONCRETE ≥ C20/25 Element TSB-F * With a landing thickness < 180 mm, the finished bracket in the SCHALL-ISOBOX® must be filled with mortar (MG IIa). DIMENSIONING THE CONNECTING LANDING SLAB Evidence of the transfer of forces into the neighbouring component must be provided by the responsible structural engineer in all cases. The properties of the connecting slab can be verified as follows: ▪▪ Use of flush beams as bar-like connections to the...

 Open the catalogue to page 10

INSTALLATION INSTRUCTIONS TSB-F: INSTALLING THE PREFABRICATED PART Prefabricated landing slab support bracket ▪▪ Produce a landing slab with bracket supports ▪▪ With regard to the landing size, the thickness of the surrounding TSP impact sound plate must be taken into account; see page 36 ▪▪ After removing the formwork, fit the impact sound box onto the bracket. Note the "THIS SIDE UP" marking TSB-F: INSTALLING THE PREFABRICATED PART ON THE BUILDING SITE ▪▪ Bond the impact sound plate type TSP to the side across the entire surface ▪▪ Align the prefabricated landing with attached impact sound boxes...

 Open the catalogue to page 11

TSB-M+B PRODUCT VERSION APPLICATION Isolation of the impact sound generated in in-situ concrete landings and staircase walls SYSTEM COMPONENTS ▪▪ TSB impact sound box ▪▪ Assembly plate for the formwork for reinforced concrete walls ▪▪ Packing for stabilisation while concreting or to support brickwork RATED VALUES FOR CONCRETE ≥ C20/25 Element TSB-M+B * With a landing thickness < 180 mm the finished bracket in the SCHALL-ISOBOX® must be filled with mortar (MG IIa). MEASURING THE CONNECTING LANDING SLAB Evidence of the transfer of forces into the neighbouring component must be provided by a structural...

 Open the catalogue to page 12