Chapter1Glassbreak/shock sensors 7
Acoustic sensor testing with the GT-2 tester
To verify sensor range and operation for 2000 model acoustic sensors, use the GT-2 tester and do the following:1.Remove the cover from the glassbreak sensor.2.To put the sensor in test mode, press the test button on the sensor two times. The sensor LEDs will blink slowly. (See the sensor installation instructions for test
button location).3.For a low frequency test , tap the wall or ceiling near the sensor. The sensor LEDs should stay lit during the alarm event.4.For a high frequency test , press the test button on the sensor two times. The sensor LEDs should blink rapidly. Place the cover on the sensor. Place the GT-2 tester behind the curtains of the window to be protected (see Figure2 on page6) and press the test mode switch on the tester ( Figure3 ). The sensor LEDs should remain lit during the alarm event.5.The sensor will time out of test mode in 15 minutes. >
Figure 3. GT-2 tester TESTLOW Test mode switch BATTERY