SplitSystemLine2008 >
Residential Line
Galletti
www.galletti.it Model >
DW 210 TW 300
Power supply V-ph-Hz 230 - 1 - 50 230 - 1 - 50
Operation Inverter DC Inverter DC Cooling mode Cooling capacity kW 1,60 ~ 6,03 2,94 ~7,35
Current absorbed A 8,2 9,9Power input kW 1,81 2,19 Yearly consuption kWh 905 1095EER 3,07 3,21
Energetic efficiency class B A Heating mode Heating capacity kW 1,75 ~ 6,71 3,18 ~ 8,25
Current absorbed A 7 9,8Power input kW 1,55 2,16
COP 4,08 3,81
Energetic efficiency class A A Indoor unit >
DIW 090 DIW 120 TIW 090 TIW 090 TIW 120
Rustic fan motor power input W 18 22 18 18 22
Sound level dBA 25 ~ 36 28 ~ 42 25 ~ 36 25 ~ 36 28 ~ 42
Dehumidification capacity litri/h 2,8 3,8
Air flow max in cooling mode m3/h 420 480 420 420 480Air flow max in heating mode m3/h 480 582 480 480 582
Dimensions: height mm 265 265 265 265 265
Dimensions: lenght mm 795 795 795 795 795Dimensions: width mm 200 207 200 200 207
Weight net kg 7,2 8,3 7,2 7,2 8,3 Outdoor unit >
DEW 210 TEW 300
Fan motor power input W 40 100Sound level cooling mode dBA 49 53
Sound level heating mode dBA 50 54
Dimensions: height mm 550 643Dimensions: lenght mm 780 850Dimensions: width mm 278 330
Weight net kg 36 51
Gas line pipe diameter mm 6 / 10 6 / 10 6 / 10 6 / 10 6 / 10Max lenght pipe m 30 45 Mas difference in height between indoor and outdoor unit m 10 10 >
Reference conditions
Cooling mode Heating mode Air temperature dry bulb 27°CAir temperature wet bulb 19°C
Outdoor air temperature 35°C
Lenght pipe 7 m Indoor air temperature dry bulb 20°C
Outdoor air temperature dry bulb 7°C
Outdoor air temperature wet bulb 6°C
Lenght pipe 7 m >
Difference in height between indoor and outdoor unit 0 m >
Difference in height between indoor and outdoor unit 0 m 13 >