video corpo

EXPRESS CATALOGUE 2012
47Pages

{{requestButtons}}

Catalog excerpts

EXPRESS CATALOGUE 2012 - 1

• All casings are hot dipped galvanised • verheat protection is fitted as standard O • High energy efficiency • Inverter controllable • Low installed noise levels Sizes 31JM - (315mm) to 100JM - (1000mm). Larger sizes up to 2800mm diameter are also available. Fan Performance All fans are tested to the latest internationally recognised standard IS05801 Part 1 (1997), installation category D (AMCA approved) for aerodynamic performance and BS848 Part 2 (1985) for acoustic performance. Coupled with a wide range of fan diameters, the adjustable pitch Aerofoil impeller gives the exact performance required, with a non overloading fan characteristic. Impellers A unique high efficiency aerofoil section blade with a purposely smoothed hub and clamp plate for adjustable pitch angle availability. Motors All motors are totally enclosed air stream rated class F insulation. Constructed from aluminium or cast iron as standard with special ‘T’ slot or pad mounted fixings. Single speed motors are suitable for speed control by voltage regulation where indicated. Three phase motors are suitable for use with frequency inverters. Two speed motors where available are pole change type. Suitable for horizontal through to vertical shaft operation. Supplied IP55, with removable drain plugs. Sealed for life bearings lubricated with wide temperature range grease. The BT and CT frames are fitted with overheat protection thermostat as standard. 80-160 frame motors are fitted with Thermistor OHP. These motors are suitable for inverter speed control down to 20% of full speed and where within scope incorporate IE2 compliant motors. Electrical Supply 220 - 240V / 50Hz / 1 Ph 380 - 420V / 50Hz / 3 Ph RANGE Temperature Range -40°C to 50°C as standard. (All motors are not suitable for starting at temperatures lower than -20°C.). When fans are operating in excess of 50°C they should be run at full speed only, fans can be operated up to 70°C with appropriate deration of motors. Most standard 3 Ph fans can be offered for a one off emergency operation at 200˚C for 2 hours. Casings JM Aerofoil fans are available in either a long cased form, complete with an externally mounted pre-wired electrical terminal box, or short cased for duct or plate installation. Casings are spun from sheet steel with integral pre-drilled and radiused inlet flanges. The galvanised finish gives a high resistance to corrosion and is ideal for external as well as internal use. Accessories Silencers, Mounting feet, Vibration isolators, Matching flanges, Flexible connectors, Air operated non return dampers, Guards, Bell mouth inlets. Electronic and transformer type speed controllers and frequency inverters. For a full range please see pages 43-48. The Fläkt Woods impellers are all high pressure die cast to offer thin aerofoil sections for low generation of noise. Every cast aluminium component is X-ray examined using Real Time Radiography inspection prior to assembly. The maximum pitch angles shown allow for speed control by frequency inverter (3ph only).

Open the catalog to page 1
EXPRESS CATALOGUE 2012 - 2

Performance Data

Open the catalog to page 2
EXPRESS CATALOGUE 2012 - 3

Performance Data 2 HOLES 23 DIA SUITABLE FOR CM20 GLANDS Product Code Electrical Data Product Code Speed rev/min Product Number Full Load Current (A) Speed Controller Sound pressure levels quoted are average dBA at 3m distance over a sphere, under free field conditions and are presented for comparative purposes only. When fans are operating in excess of 50°C they should be run at full speed only. For Short cased fans please omit the prefix from the product number and state S-type on enquiries/orders. Product numbers shown are for Long cased fans. Wiring diagrams can be found on pages 17-18....

Open the catalog to page 3
EXPRESS CATALOGUE 2012 - 4

Performance Data 3 Phase Product Code Electrical Data Product Code Speed rev/min Product Number Full Load Current (A) Speed Controller Sound pressure levels quoted are average dBA at 3m distance over a sphere, under free field conditions and are presented for comparative purposes only. When fans are operating in excess of 50°C they should be run at full speed only. For Short cased fans please omit the prefix from the product number and state S-type on enquiries/orders. Product numbers shown are for Long cased fans. Wiring diagrams can be found on pages 17-18. Bold text denotes Super Express...

Open the catalog to page 4
EXPRESS CATALOGUE 2012 - 5

Performance Data

Open the catalog to page 5
EXPRESS CATALOGUE 2012 - 6

Performance Data

Open the catalog to page 6
EXPRESS CATALOGUE 2012 - 7

Performance Data

Open the catalog to page 7
EXPRESS CATALOGUE 2012 - 9

CASED • esigned for emergency ventilation of hot D fire smoke applications High Temperature • Volume flows up to 21m3/s • Static pressures up to 600 Pa • 00°C or 400°C for two hours operation, 3 CE marked to EN12101-3 2002 • All casings are hot dipped galvanised • nverter controllable for ambient I temperatures Sizes 31JM - (315mm) to 100JM - (1000mm). Larger sizes up to 2500mm diameter are also available. Please enquire. Sizes Other sizes are available on request. Fan Performance All fans are tested to the latest internationally recognised standard IS05801 Part 1, installation category D...

Open the catalog to page 9
EXPRESS CATALOGUE 2012 - 10

Performance Data 2 Pole 6 - 31JM/16/2/5/40 EXPRESS - JM AEROFOIL HIGH TEMPERATURE Product Code Product Code Product Code Speed rev/min Product Number Full Load Current (at 400V) (A) Speed Controller Sound pressure levels quoted are average dBA at 3m distance over a sphere, under free field conditions and are presented for comparative purposes only. For Short cased fans please omit the prefix from the product number and state S-type on enquiries/orders. Product numbers shown are for Long cased fans. Wiring diagrams can be found on pages 25-26. Bold text denotes Super Express Product, next...

Open the catalog to page 10
EXPRESS CATALOGUE 2012 - 12

High Temperature Wiring Diagrams Additional circuits when fitted Thermal protection A/C Heaters When fitted * For ACDE rotation interchange supply

Open the catalog to page 12
EXPRESS CATALOGUE 2012 - 13

• 400mm - 1000mm diameter • Volume flow up to 12m3/s • Static pressures up to 650 Pa • Suitable for temperatures up to 200°C • Motor protection IP55 • Overheat protection fitted as standard • ll aluminium cast components A are x-ray examined • All casings are hot dipped galvanised • Multi-stage is available for higher pressures • All casings are hot dipped galvanised • Inverter speed controllable Sizes 40JM.Bif - 400mm, 50JM.Bif - 500mm, 63JM.Bif 630mm, 80JM.Bif - 800mm. 800 and 1000mm JM.Bif available please contact Fläkt Woods for details. Also larger sizes are available, please enquire....

Open the catalog to page 13

All FLAKT WOODS catalogs and technical brochures

  1. AP BIO

    2 Pages

  2. AP BIO

    12 Pages

  3. UV-C

    2 Pages

  4. ILOX 59PLUS

    2 Pages

  5. Shutter Roof

    2 Pages

  6. Air curtain

    12 Pages

  7. Veloduct

    66 Pages

  8. Axial Fans

    128 Pages

  9. Box Fans

    8 Pages

  10. ClimaFläkt

    93 Pages

  11. iQ Star Stella

    12 Pages

  12. Combi Cooler

    8 Pages

  13. OPTIMIX

    4 Pages