Fläkt Woods Experience at your Service Fläkt Woods is one of the worldwide leaders in the air movement. Our expertise and skills in the design and manufacture of high technological equipment enable us to offer high level integrated solutions. Within Fläkt Woods issues such as energy efficiency as well as respect and protection of the Environment are of a great importance for us and the experience we gained has no comparison. Our expertise and our reputation have been built up on a century of innovation and engineering development, thus leaving a remarkable footmark from which arises the trust...

 Open the catalog to page 2

Shops, stores, shopping centres, hotel halls as well as industrial buildings are the typical examples where the continuous opening of the doors causes an exchange between the inside and outside air, thus originating sudden temperature changes. Consequently it is evident the need to keep the two environments separated without renouncing however to a clear entrance inviting to pop in. Fläkt Woods Air Curtains are the ideal solution for this: in winter warmth is retained inside and so is for the air conditioning in summer while rejecting dust, smoke, insects and bad smell from the outside. Air Curtains...

 Open the catalog to page 3

Electrical heating Water heating Without heating FEATURES: - Visible or recessed installation - Available in different colours - Version for cooling water available Heating output: AC-Linea Heights up to 5 metres APPLICATIONS Suitable for all commercial applications Heating output: AC-Comfort Heights up to 5 metres FEATURES: - Maintenance free - Elegant front panel with integrated slots - Available in different colours APPLICATIONS Suitable for all commercial applications where high performances and good design is required Heating output: AC-Comfort Flat Heights up to 3.5 metres 4 FEATURES: -...

 Open the catalog to page 4

Horizontal installation Vertical installation Recessed installation FEATURES: - Oval design - Many options available - Available in different colours Heating output: AC-Elite Oval Heights up to 3,5 metres APPLICATIONS Suitable for all commercial applications where high performances and a stylish solutions is needed FEATURES: - Rounded design - Many options available - Available in different colours Heating output: AC-Elite Round Heights up to 5 metres APPLICATIONS Suitable for all commercial applications where high performances and a stylish solutions is needed FEATURES: - Wing spread looking...

 Open the catalog to page 5

Water heating Electrical heating Without heating Horizontal installation Vertical installation Recessed installation Heating output: AC-Industrial Heights up to 6 metres FEATURES: - No need of dust filter - Special painting for high resistance - Frost protection available as option APPLICATIONS Suitable for big opening like factories, hangars, big warehouses and similar FEATURES: - Visible or recessed installation - Two different supply throw - High energy savings - Available in different colours - Version for cooling water available Heating output: from 10.5 to 70.7 kW Soft industrial application...

 Open the catalog to page 6

Distance from the supply Air velocities at different heights* ACAC-Elite AC-Elite Oval Comfort Round Flat AC-Elite Alas ACACAxiplus Doublejet 6m * Speed values are referred to models suitable to be installed at maximum height

 Open the catalog to page 7

Air Curtains AC-LINEA RANGE Three types: water heating, electrical heating and air only version (ambient) Airflow up to 16,900 m3/h Mounting heights of up to 5 metres Plug & Play versions with pre-wired control panel AC-Linea air curtains are available for horizontal mounting above openings. Mounting heights range from 2.5 to 5 metres. The air curtain is suitable for all commercial applications: shops, ofces, shopping centres and hotels. AC-Linea range includes ve types of air curtains (S - M - G - B - BB) available in lengths of 1, 1.5, 2, 2.5 and 3 metres (the last length is available as standard...

 Open the catalog to page 8

Technical specications - “Ambient” version Model Electrical supply Volt/Hz/ph Technical specications - Electric heating version Model Electrical supply Volt/Hz/ph * Free field sound pressure level measured at 3 metres at max. and minimum speed. Air curtains with electric heater are equipped with a 3-level overheating security system.

 Open the catalog to page 9

Technical specications - Water heating version (LPHW 90/70°C and 80/60°C) LPHW 90/70°C Heat. ΔP ΔT capac. kPa °C kW 14.3 9.5 18-52 LPHW 80/60°C Heat. ΔP ΔT capac. kPa °C kW 11.9 7.1 18-47 Electrical supply Volt/Hz/ph Technical specications - Water heating version for low temperature climates (LPHW 90/70°C and 80/60°C) LPHW 90/70°C Heat. ΔP ΔT capac. kPa °C kW 19.9 27.0 18-63 LPHW 80/60°C Heat. ΔP ΔT capac. kPa °C kW 16.5 19.7 18-56 Electrical supply Volt/Hz/ph * Free field sound pressure level measured at 3 metres at max. and minimum speed.

 Open the catalog to page 10

Technical specications - Water heating version (LPHW 70/50°C and 70/35°C) LPHW 70/50°C Heat. ΔP ΔT capac. kPa °C kW 9.5 4.8 18-41 LPHW 70/35°C Heat. ΔP ΔT capac. kPa °C kW 6.6 1.2 18-34 Electrical supply Volt/Hz/ph Technical specications - Water heating version for low temperature climates (LPHW 70/50°C and 70/35°C) LPHW 70/50°C Heat. ΔP ΔT capac. kPa °C kW 13.2 13.4 18-48 Electrical supply Volt/Hz/ph LPHW 70/35°C Heat. ΔP ΔT capac. kPa °C kW 9.7 2.8 18-40 * Free field sound pressure level measured at 3 metres at max. and minimum speed.

 Open the catalog to page 11

Technical specications - Water heating version (LPHW 60/40°C and 45/35°C) LPHW 60/40°C Heat. ΔP ΔT capac. kPa °C kW 7.3 3.1 18-35 LPHW 45/35°C Heat. ΔP ΔT capac. kPa °C kW 5.1 5.5 18-30 Electrical supply Volt/Hz/ph Technical specications - Water heating version for low temperature climates (LPHW 60/40°C and 45/35°C) LPHW 60/40°C Heat. ΔP ΔT capac. kPa °C kW 9.8 8,0 18-40 Electrical supply Volt/Hz/ph LPHW 45/35°C Heat. ΔP ΔT capac. kPa °C kW 6.8 14.9 18-34 * Free field sound pressure level measured at 3 metres at max. and minimum speed.

 Open the catalog to page 12

Suction Inspection door Control Hot water heating air curtains R510: 5-step manual control (included) • 5-step manual control of the airow for up to 10 units • Wireless remote control (optional) • Automatic operation controlled by external signal (door switch, thermostat) with programmable after run timer • Solenoid valve activated by Summer/Winter switch • Fan failure report to BMS (optional) 5-step manual or automatic control • 5-step manual control of the airow • 5-step automatic control of the airow controlled by door switch (high speed) with after run timer and thermostat (step 1) • Solenoid...

 Open the catalog to page 13

All FLAKT WOODS catalogs and technical brochures

  1. Product Range-Fans

    11 Pages

    En
  2. Shutter Roof

    2 Pages

    En
  3. Vertical Roof

    2 Pages

    En
  4. Air curtain

    12 Pages

    En
  5. Veloduct

    66 Pages

    En
  6. Smoke Master SMPA

    12 Pages

    En
  7. Axial Fans

    128 Pages

    En
  8. Box Fans

    8 Pages

    En
  9. Snow screen LSJ

    3 Pages

    En
  10. ClimaFläkt

    93 Pages

    En
  11. Econet Compact

    8 Pages

    En
  12. iQ Star Stella

    12 Pages

    En
  13. Combi Cooler

    8 Pages

    En
  14. OPTIMIX

    4 Pages

    En