C-90 MB 5 PE (1) - 2 Pages

Sewage treatment / Oxyfix® C-90 MB 5 PE (1)

Product : Sewage treatment plant
Type :
Model :
Process :

Oxyfix® C-90
C-90 MB 5 PE (1)
Submerged fixed bed

PERFORMANCE
Considered influent water
Characterization  :
Pollutant load BOD5 :
Pollutant load COD :
Pollutant load SS :
Hydraulic load :

Sewage*
0,300 kg O2/day
0,675 kg O2/day
0,450 kg/day
0,750 m3/day

Purification performance
< 25
< 125
< 30

BOD5 :
COD :
SS :

mg O2/liter
mg O2/liter
mg/liter

COUPE AV-AV

* For the wastewater from a restaurant, a canteen…. We recommend placing a grease trap.
( 1/65 )

O P E R AT I O N
H
OUT

IN

F
B

A

C

D

E

G

ELECTROMECHANICAL KIT

Legend
A
B
C
D
E
F
G
H

Blower
Quantity :
Type :
Installed power :
Power consumption :
SPL (Sound Performance Lab) :
On / Off :
Voltage :

pc(s)
1
diaphragm blower
0,060 kW
0,052 kW
dB(A)
36
60/00 min.
1x230V

AU

Diffusers
Quantity :
Type :

AV

Primary settling compartment
Biological reactor
Secondary settling compartment
Bacterial support
Diffusers
Sludge recirculation
Settling cone
Ventilation

AU

AV

pc(s)
2
fine bubbles

Secondary sludge recirculation
airlift
-

Type :
Installed power :
Power consumption :
On / Off :

kW
kW
min.

A P P R O VA L S A N D C E R T I F I C AT E S
: 2012/04/132/A
: EN 12566-3 CPD 89/106/CEE
: CRT-009-KW

Control panel
Type :

(option)

Eloy Water

sa

Zoning de Damré
rue des Spinettes 13

4140 Sprimont
B e l g i u m

T. +32 4 382 44 00
F. +32 4 382 44 01

info@eloywater.com
www.eloywater.com

C-90 MB 5 PE (1)
  1. P. 1

  2. P. 2

    Measure UnitTank 1Total height* : Entry height* : Exit height* : Length : Width : Total volume : Useful volume : Weight : Manhole(s) : Ø...
Text version

All Eloy Water catalogues and technical brochures

  1. CB 38 EH (3)

    2 Pages

    En
  2. MB 27 EH (2)

    2 Pages

    En
  3. MB 17 EH (2)

    2 Pages

    En
  4. C-90 MB 9 PE (2)

    2 Pages

    En