Heat Pumps
15Pages

{{requestButtons}}

Catalog excerpts

Heat Pumps - 1

PRODUCT DATA SHEETS HEAT PUMPS

Open the catalog to page 1
Heat Pumps - 2

HIGH-TEMPERATURE BRINE-TO-WATER HEAT PUMP: UNIVERSAL DESIGN - MAX. FLOW TEMPERATURE 70 °C HIGHER FLOW TEMPERATURES FOR HEATING AND DOMESTIC HOT WATER PREPARATION LOW-TEMPERATURE HEATING SYSTEMS AND DOMESTIC HOT WATER UP TO 60 °C Usually, when a heating system is modernised, a new, more High-temperature brine-to-water heat pumps are also suitable efficient heat generator must be integrated into an existing heat for new buildings. Excellent COPs can be achieved in distribution system. More often than not, the necessary flow combination with underfloor heating. High-temperature heat...

Open the catalog to page 2
Heat Pumps - 3

HIGH-TEMPERATURE HEAT PUMP Maximum flow temperature of 70 °C Hot water temperatures up to 60 °C with heat-pump-only operation High COPs through economiser Universal design for customisation of the distribution system Can be used for heating, domestic hot water and swimming pool water preparation UNIVERSAL DESIGN FOR FLEXIBLE USE Due to their universal design with integrated heat pump manager, the heat pumps can be adapted to numerous customer requirements: These heat pumps can be used as monovalent heat pump heating systems or in combination with other heat generators, if necessary, they...

Open the catalog to page 3
Heat Pumps - 4

Hydraulic Tower with Heat Pump Manager For air-to-water heat pumps installed outdoors Hydraulics – often underestimated but so important The simple and quick way to the perfect hydraulics The required heating water flow must be guaranteed in all The HPK 200S hydraulic tower is simply connected to the operating conditions for trouble-free operation of the heat pump. air-to-water heat pump installed outdoors via one electric and Coupled with a sufficiently large heating water volume, this two hydraulic connecting lines. The integrated components for ensures the minimum runtimes of the...

Open the catalog to page 4
Heat Pumps - 5

HPK 200S hydraulic tower High degree of operational safety and fast installation Integrated buffer tank (200 l), expansion vessel (24 l) and switchable supplementary heating (2, 4, 6 kW) Integrated circulating pumps ensure the heating water flow and supply an unmixed heating circuit Heat pump manager with all components connected ready-for-use Can be expanded to include domestic hot water preparation and an additional mixed heating circuit Energy saving hydraulics The dual differential pressureless manifold enables the maximum variety of hydraulic options without compromising when it comes...

Open the catalog to page 5
Heat Pumps - 6

REVERSIBLE BRINE-TO-WATER HEAT PUMP: Optimised for cooling operation with waste heat recovery Increased cooling requirements in buildings Nowadays, in many buildings the cooling requirements are The Solution: the reversible heat pump from Dimplex for heating and cooling higher than the heating requirements. The reasons for the The reversible brine-to-water heat pump from Dimplex is an increased cooling requirements and the lower heat consumption energy-efficient heating and cooling device. The integrated are obvious. The heat consumption is lower in buildings which regulation enables...

Open the catalog to page 6
Heat Pumps - 7

Reversible brine-to-water heat pump Max. flow temperature in heating operation 55 °C Min. flow temperature in cooling operation 8 °C Can be used for heating, cooling, domestic hot water and swimming pool water preparation Domestic hot water temperatures up to 60 °C with simultaneous heating or cooling request Heating and cooling with two compressors to permit flexible adaptation of the performance Heat pump manager with heating and cooling regulation The integrated regulation enables permanent heating or cooling operation with parallel domestic hot water or swimming pool water preparation....

Open the catalog to page 7
Heat Pumps - 8

Compact Brine-to-Water Heat Pump with high flow temperatures for domestic hot water preparation Optimal utilisation of the living space in new buildings The high level of thermal insulation in new buildings makes the The compact heat pump that does not require a heating element use of heat pumps even more efficient. Due to the low heat The high-temperature brine-to-water heat pump with hot water outputs, heat pumps are the clear winner in investment and cylinder meets the high demands of the technicians and operating cost comparisons with other heating systems. And the customers. The heat...

Open the catalog to page 8
Heat Pumps - 9

Compact brine-to-water heat pumps with domestic hot water preparation Compact design for direct connection of the heating and brine circuits Sound-insulated refrigerating circuit with economiser for high coefficients of performance Hot water temperatures up to 60 °C with heat-pump-only operation Wired ready for use for an unmixed heating circuit Heat pump and hot water cylinder can be transported separately Heat pump manager – the intelligent regulation The heat pump manager monitors the operation of the heat pump and offers all the functions of a modern heating regulation system, such as a...

Open the catalog to page 9
Heat Pumps - 10

Medium-Temperature Air-to-Water Heat Pumps Compact design for simple installation Tapping the air as heat source Compact design with high operational safety Dimplex air-to-water heat pumps are available for indoor and The LIKI 14TE air-to-water heat pump makes installation easy, outdoor installation. While for outdoor installation the air circuit quick and safe. The integrated air circuit with 90° air deflection is already installed in the heat pump, it must be configured for enables direct corner installation without air ducts or wall indoor installation. Installation can be in a corner...

Open the catalog to page 10
Heat Pumps - 11

Medium-temperature compact air-to-water heat pump Flow temperature of up to 65 °C Integrated heat pump manager with removable control panel High COPs due to high-performance evaporator Sound-optimised through low-noise ventilator and encapsulated compressor housing Hot water temperatures up to 60 °C with heat-pump-only operation Energy saving hydraulics The dual differential pressureless manifold enables the maximum variety of hydraulic options without compromising when it comes to efficiency. The hydraulic isolation is realised using two differential pressureless manifolds (bypass pipes)...

Open the catalog to page 11

All Dimplex catalogs and technical brochures

  1. LA 40TU-2

    5 Pages

  2. LA 0712BW

    2 Pages

  3. LA 0712BWC

    2 Pages

  4. LA 3860

    2 Pages

  5. Heat pump

    34 Pages

  6. SI 90TU

    6 Pages

  7. SI 22TU

    6 Pages

  8. LI 24TES

    10 Pages

  9. DHW 300

    2 Pages

  10. LA 60S-TU(R)

    4 Pages

  11. M Flex Air

    2 Pages

  12. M Flex

    6 Pages

  13. System C.

    9 Pages

  14. Plus Magazine

    100 Pages

  15. LIK12TU

    2 Pages

  16. System M.

    2 Pages

  17. System M

    15 Pages

  18. System Zero

    11 Pages

  19. DHW 400+.

    2 Pages

  20. Splydro

    2 Pages

  21. NEWS 2013

    11 Pages

Archived catalogs

  1. Product range

    118 Pages