WSAT WSAN 292614
y 2 □ DC □ >-i
Water chiller
► WSAT: cooling only
► WSAN: modern heat pump Air cooled Outdoor installation
Capacity from 81,4 to 160 kW
On Line Selection Program
Liquid building chillers of the WSAT and WSAN series are units designed for outdoor installation and for best energy efficiency.
The compressors are of the hermetic Scroll type. The units are fitted with an innovative microprocessor control for regulating and optimising all functions, thereby increasing the partial-load energy efficiency. An enamelled, hot-galvanised sheet metal load-bearing frame with prepainted aluminium outer panelling ensures maximum resistance to weathering. The base, made from painted galvanised metal sections with holes to facilitate lifting and earthing the unit, guarantees even weight distribution.
All the units are factory assembled and tested and ready for operation after connection to the electricity and water supplies, with consequent substantial reduction in installation costs.
functions and features
J I
JBREEZ^
ECOBreeze
Cooling only (WSAT)
Heating-Cooling (WSAN)
Outdoor inst.
Refrig. R407C
Refrig. R-22
Herm. Scroll
Free-Cooling
Air cooled
Ice protection system
available configurations
-
B
FC
404
ST
T
C
WSAT-2
(1) ENERGY RECOVERY:
(3) ENERGY SAVING:
► FCD Direct Free-Cooling
Version that allows cold to be recovered at no cost from the ambient when the external air temperature is lower than the system return water temperature.
(4) ACOUSTIC CONFIGURATION: 4 ST Standard
4 LN Silenced
This set-up is obtained by inserting the compressors in a soundproofed compartment and reducing the home fan speed of rotation with an uprated condensing section.
(5) ENERGY EFFICIENCY:
4 T Temperate climate (Standard)
(6) EXCHANGER APPROVALS:
4 CE PED (European test)
► C Clivet (In-house test)
► -
4D
Not required Partial recovery
Carried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat.
4R
Total recovery
Carried out using tube bundle exchargers suited for 100% recovery of condensation heat for producing hot water.
(2) LOW TEMPERATURE:
4 B Low water temperature
This version allows unit operation within the water and glycol mixing temperature range be^een +5°C and -8°C inclusive.
Two versions are available
- Unit for low temperatures only
- Unit with double operating set-point
The possibility of reducing the cooling capacity depends on the working temperature. Check with our sales office.
28
%= CLIVET'
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
pdf-page pdf ae En 2008-11-47-21