Catalogue Guide to the products for air conditioning
www.clivet.it
print switch display
Page / 150
Clivet - 110055, 28026
/ 150
See other catalogues for Clivet
Text version of the page
accessories
y z □ DC 13 >-i
Rubber antivibration mounts
Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/aluminium with Fin Guard (Silver) treatment
Copper/copper condenser coil Serial communication module (MODBUS) Steel mesh filter on water side Room keypad
Service keypad (cable from 1,5 metres) Phase monitor
Double temperature control kit, set point compensation 4-20 mA, 3-way valve
Set point compensation with according to outdoor enthalpy
S
4 Unit without hydronic group WSAT-EE only:
Q 4 Device for operation with low external air temperature with variable contemporary fan speed
S 4 Set point compensation with fresh air sensor
S S
s s s s
s
Key to symbols:
Q Accessories supplied separately.
technical data
Sizes
51
► Cooling capacity WSAT-EE
(1)
kW
12,3
Total input WSAT-EE
(1)(2)
kW
4,33
Total EER at 100% - WSAT-EE
2,84
ESEER - WSAT-EE
3,25
4 Heater capacity
(3)
kW
13,6
Total input
(2)(3)
kW
4,40
COP
2,89
Pump working head WSAT-EE
(1)
kPa
135
Number of refrigerant circuits
Number and type of compressors
(4)
Sound pressure level WSAT-EE
(5)
dB(A)
60
Power supply
V/Ph/Hz
61
71
81
91
14,4
16,2
18,2
21,2
5,22
5,79
6,50
8,31
2,76
2,80
2,80
2,55
3,42
3,28
3,28
3,00
16,3
18,0
20,6
24,3
5,00
5,76
6,46
8,23
3,01
2,92
3,00
2,85
131
116
118
97
1
1 SCROLL
60
60
62
63
400/3/50+N
Data referred to the following conditions:
(1) Internal exchanger water = 12/7°C; external air temperature 35°C.
(2) Total input is obtained from the compressor input + fan input + auxiliary circuit input.
(3) Ambient temperature = 7°C (R.H. = 85%); internal exchanger water outlet temperature 45°C.
(4) ROT = rotary compressor
(5) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions.
dimensions and functional spaces
Sizes
51
61
71
81
91
WSAT-EE
Length (A)
mm
1040
1040
1325
1325
1325
Width (B)
mm
411
411
555
555
555
Height (C)
mm
1175
1175
1225
1225
1225
4(A1)
mm
100
100
100
100
100
(A2)
mm
500
500
500
500
500
(B2)
mm
150
150
150
150
150
Weight in oper.
Kg
120
124
162
165
168
WSAN-EE
Length (A)
mm
1040
1325
1325
1325
1325
Width (B)
mm
411
555
555
555
555
Height (C)
mm
1175
1225
1225
1225
1225
MA1)
mm
100
100
100
100
100
(A2)
mm
500
500
500
500
500
(B2)
mm
150
150
150
150
150
Weight in oper.
Kg
130
170
172
175
178
The above data refer to standard units.
-or trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
CAUTION!
19
ftjDJVET'
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
pdf-page pdf ae En 2008-12-49-03