Contrôle d’accès centralisés
CA-A480-A Elevator Controller
Connected to the CT-V900-A controller’s expansion bus, each CA-A480-A can control up to 16 floors. The CAA480-Afloor control relays can be interfaced directly with an elevator’s floor control buttons. When a valid card is presented,
the appropriate floor control relays will become enabled allowing the cardholder to select the desired floor. DestinationControlled Mode, which requires a CA-A482-P Destination Reporting Module, offers far superior event trail and useraccountability. In addition to these advanced floor and elevator control features, the CA-A480-A also features
full supervision, backup battery and a
fire alarm input. >
Caractéristiques techniques :
16 on-board floor control relays Fire control input >
152
184 Control up to 64 floors and 2 elevator cabs Destination reporting (requires CA-A482-P
Destination Reporting Module) Connects directly to the RS-485 E-BUS Backup battery with selectable battery charge current Individual schedules per floor with on-board 12Vdc power supply Fully supervised (tamper, low battery and AC failure) with comprehensive LED display Fire alarm: 1 Tamper: 1 Relay outputs: 16 form C relays rated at 20A/16Vdc, N.C./N.O >
+ 5° C à + 55° C CA-A480-A CodeRefDescription F0111000030CA-A480-ANB16 FLOORS ELEVATOR CONTROLLER WITHOUT BOX F0111000006CA-A480-A16 FLOORS ELEVATOR CONTROLLER >
CA-A482-P Destination Reporting Module (DRM)
The DRM has 16 Floor Selection inputs, one for each floor control relay of the CA-A480-A Elevatorcontroller. Once a card is presented, the user can only select one floor. Once the floor is selected,all other floor selection buttons are de-activated. The user must present their card again in orderto select another floor. Each card swipe and individual floor selection is recorded by the system. >
130 Technical features :
Connects directly onto the CA-A480-Aelevator controller One-card swipe, one-floor operation Eliminate elevator cab tailgating. Each rider
must present their card to select a floor button >
127 16 floor-selection inputs and LED indicators Records Valid and Invalid floor selections Power input: 5Vdc Current consumption: 28mA (typical), 108mA (max) Inputs: 16 floor selection inputs Select activation LED: Yes (16 LEDs) DC input activation: 15Vdc (minimum), 16.5Vdc (max) Connection method: 14-way Flat Cable to CA-A480-A >
+ 5° C à + 55° C CA-A482-P CodeRefDescription F0111000007CA-482-PDESTINATION REPORTING MODULE >
20
www.cdvi.comwww.cdvgroup.com >