Contrôle d’accès centralisés
CT-V900-A 2-Door Controller
The CT-V900-A is at the heart of every access control system. The Server, hardware expansion modules,multi-purpose inputs, card readers, keypads and outputs are connected directly to the CT-V900-A.
Multi-controller systems are joined together via the RS-485 communication bus. Distributed database
architecture allows each controller to make split-second decisions without the need of the server computer.
Lightning-quick, robust and remarkable stability make the CT-V900-A the professional’s choice.
330
390
100 Caractéristiques techniques
Control 2 doors (Reader In / REX Out) or 1 Door (Reader In / Reader Out) Add up to 6 more doors to the CT-V900-A using
the CA-A470-A expansion module 10,920 on-board card database 256 Schedules 256 Access Levels 2048 Event Buffer 16 on-board inputs (*using ATZ 2R/3R) 2 on-board 12 Vdc or 24 Vdc field-selectable
lock outputs 2 on-board Form C dry contact relay outputs
(N/O - N/C) Fully distributed database architecture (access decisions
made locally) Flash firmware - Upload firmware via the computer >
CT-V900-A E-Bus technology add-on hardware modules can be up to 1220m (4000ft) away from the CT-V900-A 2.5A switching power supply >
+ 5° C à + 55° C Supports common Wiegand, Track 2 ABA (mag stripe) and BCD (keypad) formats >
Input Specifications :
Easy maintenance with snap-off terminal blocks Reader Inputs/Ports: 2 Battery backup functionality (2 x 12V 7AH
gel-type batteries) Keypad Inputs/Ports: 2 Multi-purpose Inputs: 16 (using ATZ 2R/3R) Lithium battery protection in case of complete power failure >
Output Specifications :
12/24Vdc Lock outputs: 2 >
Communication :
Relays: 2 Form C Dry Contact 5A/30Vdc N.C/N.O Plug and play technology Reader Outputs: Six 25mA Open collector outputs (Red/Green LEDs, Buzzer) RS-485 E-Bus for expansion modules Connect modules up to 1220m (4000ft) away
from the controller >
Electrical Specifications :
RS-232/485 port enabling communication
with the software Power input: 24Vac, 75VA or higher, 50/60Hz transformer Supply current: 2.5A maximum Battery capacity: Two 12Vdc, 7Ah, acid/lead gelcell batteries >
Elevator Control :
Controlled
elevators: 2 cars/cabs with 64 floors
per car/cab >
On-board Protection :
Schedules per floor: Yes Auxiliary outputs: 2.5A (24Vdc), 1A (12Vdc & 5Vdc)
fuseless protection Floor groups: 128 Requirements: Standard, Professional or Enterprise edition software AC protection: 5A fuse Battery reversal: 7A fuse CodeRefDescription F0111000001CT-V900-ANB2-DOOR CONTROLLER WITHOUT BOX F0111000028CT-V900-A2-DOOR CONTROLLER WITH BOX F0111000003TR24/7524 V 75 VA CLASS 2 TRANSFORMER >
14
www.cdvi.comwww.cdvgroup.com >