Product catalogue - 19 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

simple and complete construction system HD III block with insulation for external bearing walls, with high thermal insulation For millennia, wood has been the most widely used raw material. This fact has contributed con- siderably to the development of wood-concrete formwork blocks that in many northern countries (Germany, Austria, Switzerland) have been suc- cessfully used for over 60 years. The wood is ground, then mineralized with the aid of the cement; this mix, via a block-making machine, is turned into solid blocks. In this way the porous structure, which is very important for the transpiration...

 Open the catalogue to page 2

... with full respect for bio-building Within Federal Germany, after passing the rela- tive tests, the formwork has been recognized as a biological material, and constant company and government controls ensure the best unchange- able quality. Besides the remarkable technical characteristi- cs, the Isotex formwork offers fast and easy in- stallation. You start by laying the first course with mortar so as to level it; the following courses are laid dry, and on reaching a height of approxi- mately 1.5 m the concrete is poured. The remarkable lightness of the block, its dimen- sions (8 pieces per...

 Open the catalogue to page 3

* The calculation of the thermal transmittance has been made according to the criteria of the UNI 10355 stan- dard and the EN ISO 6946 standard, using a three-di- mensional calculation program with finite elements va- lidated according to EN 10211/1 and on the basis of the thermal conductivity data obtained from experimental • For this block are not provide technical values as it does not meet current standards. ** Note: The test certificates can be requested from ISO- TEX or viewed on the WEBSITE. These are site tests values that have been processed according to the clues provided in the technical...

 Open the catalogue to page 4

STANDARD BLOCKS HDIII 33/14 HDIII38/14 with graphite Dill 38/12 with cork DIM 44/18 with graphite HB 44/15-2 *** Test performed in the laboratory with the standards UNI EN ISO 140-3:2006 and UNI EN ISO 717-1:2007 **** Test performed in the laboratory with the standards UNI EN ISO 140-3:2010 and UNI EN ISO 717-1:2007 FORMWORK BLOCKS ISOTEX COMPLY AT THE REQUIREMENT OF THE GUIDELINES APPROVED FROM THE MINISTRY OF PUBLIC WORK. (JULY 2011). Shoulder block straight shoulders.

 Open the catalogue to page 5

hygrometric tests provi ni immoral per nu'ta La prova e consistita nell'iromerqere in acqua distillata per acta al tezza un provino essiccata e nel verificare a vista, sulla superficit esterna ed a intervalli reqolari. la risalita dell'acoua sul provino, Risultati dclla prova : I risultati dolle prove efFettuate eviden.ii-.no la differenza struttu- rale dei blocchi a cassero Isotex esaminati coi normal! blocchi in la- terizio : il basso valore della dennita dei blocchi a cassero Isotex, 500 kq/m3 rispetto ai 1200 * lflOO kq/m3 dei blocchi in laterizio, 6 dovuta eseenzialmente alia loro struttura...

 Open the catalogue to page 6

fire rating tests with loaded walls and floors CLASSIFICA TION REPORT I fuoco del solaio port«nte cfRnomlnuto Resistance to fair rfjssificttticn repcit tor I'm ksidte/yanng llocv namr/d Norma tecnlca ferhn■est :;Ki.-vJ:itJ prodolli o doull elainonll da coatruzione - Pprlo 2: CloBsillqiifione aullo baao dui (fall di provn dciivali da provo di loaitiUwu ul fuoco, olomonll di VimltWIone construction products unif building Clements - Putt 2: Classification using test data from Urn rasislanco fusts, excluding vonMahon services ScSo fa stj*n cor.jSet 5 1. Rifstimontn delln claiiailu:fi/itirm / Rofaronco...

 Open the catalogue to page 7

construction details Corner with blocks of thickness 30 cm. The spe- cial piece called UNI rh is positioned on the side of the 30 cm block the block 45 cm long called PASS should be inserted to bring the module to blocks are laid in the two directions of the wall. The UNI Ih block is positioned on the next course so as to cross and bind the corner well, repeating the operation as above (45 cm block in the direc- tion of the 30 cm thickness of the UNI block). Half rh and half Ih blocks should be inserted in each pack of UNI blocks. Before positioning the UNI blocks it is necessary to create an...

 Open the catalogue to page 8

construction details FORMWORK BLOCKS ISOTEX COMPLY AT THE REQUIREMENT OF THE GUIDELINES APPROVED FROM THE MINISTRY OF PUBLIC WORK. (JULY 2011). Alternating UNI universal blocks with TS half blocks makes the shoulders of doors and windows. Lintels of doors and windows are made by cutting the TS blocks on site. In this way, cold bridges are eliminated. REINFORCEMENT OF WALL OF ISOTEX BLOCKS VERTICAL SECTION JUTTING REINFORCEMENT REINFORCED BELT DIFFUSED VERTICAL DIFFUSED HORIZONTAL FLOOR SLAB RESUMPTION FROM HORIZONTAL SECTION DIFFUSED HORIZONTAL REINFORCEMENT HORIZONTAL REINFORCEMENT DIFFUSED VERTICAL...

 Open the catalogue to page 9

instructions for laying blocks When making the foundation it is necessary to in- sert the vertical reinforcement with a pitch of 25 cm (the pitch of the holes in the blocks) with a height of approximately 50 cm (fig. 6 page 8). The other possibility is to insert this vertical reinforcement with resins on the made foundation with the first course of blocks laid. The first course is laid on two layers of mortar posi- tioned only in correspondence with the walls of the blocks in order to be able to level it properly (it is recommended to use a spirit level);the layer of mortar on the entire width...

 Open the catalogue to page 10

technical instructions plaster set, on average an interval is needed of at least 3-4 weeks; this time varies depending on the climatic conditions. For this type of finish (for the outside) that, to be suc- cessful, must be made with the undercoat (15 mm) fully ripened in order to avoid the formation of cracks, the objective difficulty in checking the undercoat has fully ripened, and control that modality and time of application are fully respected. One solution more su- itable we can easily support, considering the positive experience had since 1995 on differents sites, consi- dering that in the...

 Open the catalogue to page 11

element in wood concrete for floor slab The positive experience of over 60 years obtained with using wood-concrete blocks, C&P has realized a project that utilizes wood-concrete elements for The goal, as we will see in the following documenta- tion, is to resolve, with a single operation, situations such as completely eliminating all the relative noise and cold bridges for a construction, the fire rating, thermo-acoustic insulation, taking advantage in this sense of the greater inertia of this floor sla compa- red to several other solutions. The bearing structure obtained inside the element, added...

 Open the catalogue to page 12