Stand
Group: Hager Group
video corpo

Berker Catalogue - 636 Pages

IR push-button 4gang with room thermostat and display
polar white, matt 7566 46 99 1
stainless steel 7566 46 93 1
glass, polar white 7566 46 91 1
Operating temperature -5 - +45 °C
IR hand-held transmitter order no. 2779 see house electronics.
Only for bus coupling unit plus order no. 7504 00 03 Labelling field see accessories order no. 7590 00 81
IR push-button 5gang with room thermostat and display
polar white, matt 7566 56 99 1
stainless steel 7566 56 93 1
glass, polar white 7566 56 91 1
Operating temperature -5 - +45 °C
IR hand-held transmitter order no. 2779 see house electronics.
Only for bus coupling unit plus order no. 7504 00 03 Labelling field see accessories order no. 7590 00 82
■ for installation in Igang wall boxes
■ with anti-dismantling protection
■ with blue operation LED and 8 white status LED (labelling field illumination)
■ Lc display with symbols and illumination, switchable via object
■ display of operating mode, controller lockout, room/ outside temperature, time (clock required)
■ text display (ASCII-format)
■ with 2 additional display buttons
■ button help function can be activated
■ end customer display scope parameterisable
■ for switch, push-button, dimmer, shutter and room thermostat functions
■ IR telegram with RC5 coding parameterisable per push-button
■ value transmitter for dimming, position, brightness and temperature values 1 and 2 byte
■ extension unit for light scene push-button
■ cyclic transmission can also be started via switching object
■ single and two push-button operation paramete-risable
■ one push-button operation for switching, pushing, shutters and dimming
■ area dimming
■ shutter operation concept short-long-short and long-short parameterisable
■ rockers or push-button lockable via object
■ alarm telegram after disconnection from bus coupling unit 1 bit, 1 or 2 byte
■ with room temperature timer and 2-week timer functions
■ for individual single room control
■ controller operating modes: comfort, standby, night and frost/heat protection mode
■ for heating and/or cooling mode with/without auxiliary step
■ control parameter for heating / cooling unit pre-set
■ for continuous (PI) or switched (2-point) control of max. 2 control circuits
■ temperature measurement via internal and/or external sensor with mean value formation
■ presence button parameterisable to extend comfort
■ separate window contact object
■ indicator objects for heating and cooling
■ with valve protection function
■ object for controller status
■ with button lock function
■ with flash-controller technology
■ programmable with ETS2 as of V1.2a and ETS3
■ for installation in Igang wall boxes
■ with anti-dismantling protection
■ with blue operation LED and 10 white status LED (labelling field illumination)
■ Lc display with symbols and illumination, switchable via object
■ display of operating mode, controller lockout, room/ outside temperature, time (clock required)
■ text display (ASCII-format)
■ with 2 additional display buttons
■ button help function can be activated
■ end customer display scope parameterisable
■ for switch, push-button, dimmer, shutter and room thermostat functions
■ IR telegram with RC5 coding parameterisable per push-button
■ value transmitter for dimming, position, brightness and temperature values 1 and 2 byte
■ extension unit for light scene push-button
■ cyclic transmission can also be started via switching object
■ single and two push-button operation paramete-risable
■ one push-button operation for switching, pushing, shutters and dimming
■ area dimming
■ shutter operation concept short-long-short and long-short parameterisable
■ rockers or push-button lockable via object
■ alarm telegram after disconnection from bus coupling unit 1 bit, 1 or 2 byte
■ with room temperature timer and 2-week timer functions
■ for individual single room control
■ controller operating modes: comfort, standby, night and frost/heat protection mode
■ for heating and/or cooling mode with/without auxiliary step
■ control parameter for heating / cooling unit pre-set
■ for continuous (PI) or switched (2-point) control of max. 2 control circuits
■ temperature measurement via internal and/or external sensor with mean value formation
■ presence button parameterisable to extend comfort
■ separate window contact object
■ indicator objects for heating and cooling
■ with valve protection function
■ object for controller status
■ with button lock function
■ with flash-controller technology
■ programmable with ETS2 as of V1.2a and ETS3
Berker Catalogue
  1. P. 1

  2. P. 446

    Controller sensor 180 comfort with slide ■ switch for off/automatic/on polar white, glossy # 7526 14 69 1 f red, glossy #752614...
  3. P. 447

    SH-BUTTON Push-button 4gang standard polar white, matt 7516 40 99 stainless steel 7516 40 93 glass, polar white 7516 40 91 Operating...
  4. P. 448

    Push-button 2gang comfort polar white, matt 7516 25 99 stainless steel 7516 25 93 glass, polar white 7516 25 91 Operating temperature...
  5. P. 449

    Push-buttons with room thermostat and display M > Push-button 3gang with room thermostat and display polar white, matt 7566 35 99 1...
  6. P. 450

    IR push-buttons with room thermostat and display Push-button 5gang with room thermostat and display polar white, matt 7566 55 99 1 stainless...
  7. P. 451

  8. P. 452

    Order no. Packing Order no. Packing unit unit SH-BUTTONS BCU / GROUP PUSH-BUTTONS BCU Push-button BCU's Push-button...
  9. P. 453

    Order no. Packing Order no. Packing unit unit Emergency switch covers Group push-button BCU 2gang light grey 7519...
  10. P. 454

    INSTABUS KNX/EIB QUICK OVERVIEW SWITCH / SHUTTER ACTUATORS Feature Switch actuator 2gang 16 A, order no. 75312008 Switch actuator 4gang...
  11. P. 455

    INSTABUS KNX/EIB QUICK OVERVIEW SWITCH / SHUTTER ACTUATORS Feature Shutter actuator 4gang 230 V AC / 2gang Switch / shutter actuator 8/4gang...
  12. P. 456

    INSTABUS KNX/EIB QUICK OVERVIEW DIMMING ACTUATORS DALI GATEWAY Feature Universal dim actuator 4gang, 20-210 W/VA, order no. 75314017 Universal...
  13. P. 457

  14. P. 458

  15. P. 459

  16. P. 460

  17. P. 470

  18. P. 480

  19. P. 490

  20. P. 500

  21. P. 600

Text version

All Berker catalogues and technical brochures

Archived catalogues

  1. Arsys copper Med

    1 Pages

    En
  2. Berker Arsys

    2 Pages

    En