video corpo

PAC + / PAC + R
2Pages

{{requestButtons}}

Catalog excerpts

PAC + / PAC + R - 1

FC PAC+ 08-1050-EN:Mise en page 1 10-10-2008 12:10 Pagina 1 PAC + / PAC + R PAC + PAC +R 3 models from 8 to 14 kW PAC + / PAC + R PAC + / PAC + R 08 PAC + / PAC + R 10 PAC + / PAC + R 12 8.1 2.3 3.53 6.2 2.3 5.1 2.3 1.43 48 11.2 3.1 3.6 8.1 3.0 7.2 3.1 1.97 33 14.1 3.9 3.63 10.0 3.6 8.7 3.7 2.52 51 HEAT PUMPS Water system at 30/35°C Capacity at outside temp. of 7°C kW Power input Heating kW COP Capacity at outside temp. of 2°C* kW Power input at outside temp. of 2°C • • • • Operates at outside temperatures of up to -15°C. Water leaving temperature up to 55°C Low noise levels Compatible with heated flooring, radiators and water terminal units. kW Power input at outside temp. of -7°C kW Nominal water flow m3/h Available hydraulic pressure (HS) kPa Outdoor temperature operating limits see the technical sheet for detai- °C Min./max. water leaving temperature led operational data °C Capacity at air temp 35°C, water temp 18/23°C (PAC + only) kW Power input Cooling kW EER Outdoor temperature operating limits °C kW kW Heating capacity at outside temp. of -7°C* 2 VERSIONS TO SUIT ALL YOUR NEEDS Capacity at outside temp. of 7°C Power input kW Power input at outside temp. of -7°C • Designed to power heated flooring, radiators or water terminal units • Reversible: Heater mode and cooling mode • Built-in 6 kW electrical supply point • Safety power-off switch • Built-in 5 l expansion tank • Supplied with room thermostat • Designed to fit with your existing heating installation, and to releave your boiler if necessary • Heating mode only • Optional control management kit with programmable room thermostat • Optional hydraulic connection kit with 3-way valves kW Nominal water flow PAC + R: This heat pump releaves your boiler m3/h Available hydraulic pressure (HS) kPa Outdoor temperature operating limits see the technical sheet for detailed operational data 7.7 2.8 5.1 2.8 1.36 50 °C Capacity at air temp 35°C, water temp 7/12°C - PAC + only kW Power input kW Sound pressure level at 5m in open space** dB(A) dB(A) 5.6 2.5 39 64 Weight kg 180 mm Electrical heater capacity (PAC + only) kW 7.7 3.6 39 64 183 Compressor type inches litres Power cable (PAC + /PAC + R) mm2 Main fuse (PAC + /PAC + R) A Power cable (PAC + /PAC + R) mm2 Main fuse (PAC + /PAC + R) A 188 1150x401x1309 6 (2+4) Coaxial 1” female 1” female inches Expansion tank (PAC + only) Power supply 3N~400V Water inlet Water outlet Power supply 1~230V 7.1 4.2 39 64 Scroll Heat exchanger Pipe line 13.6 4.6 9.1 4.5 2.43 55 -15°C 25°C / 55°C Sound power level** Cooling 10.7 3.8 6.9 3.7 1.90 38 °C Min./max. water leaving temperature STANDARD EQUIPMENT PAC + only: • 5-litre expansion tank • 6 kW electrical heater • Room thermostat 9.8 4.5 2.21 20°C / 45°C 7°C / 18°C Dimensions (WxDxH) • Scroll compressor • Smooth hydrophilic fin heat exchanger • Ventilators with protruding blades • Heat exchange protection grille • Coaxial heat exchanger • Electric and control panel • Phase controller for three-phase models • softstarter device on single-phase models • Cycle inversion valve • 3-speed water circulation pump • Safety selector • Automatic purging • Safety valve • Water filler valve • High-/Low pressure pressostats 8.9 3.7 2.42 Water system at 40/45°C Heating PAC + : This heat pump provides for heating needs only 7.2 2.5 2.84 °C Min./max. water leaving temperature -15°C 25°C / 55°C 5 3x10 / 3x2.5 63 / 20 - 5 3x16 / 3x4 63 / 25 5x4 / 5x2.5 25 / 16 5 3x16 / 3x6 63 / 32 5x4 / 5x2.5 32 / 16 * Value includes defrosting. ** Sound level of units equipped with sound insulation on compressor (supplied as standard). Add 3 dB(A) is this insulation if removed. Your official dealer Airwell Group 1bis, Avenue du 8 mai 1945 Saint Quentin en Yvelines 78284 GUYANCOURT France Tel. +33 (0)1 39 44 78 00 Fax +33 (0)1 39 44 65 17 www.airwell.com CM PAC+ 1 - A.1 GB - These specifications are intended as a guideline and are subject to change without notice - photos are non-contractual - Printed in EU. • “Ready to use” monobloc, all parameters set at the factory. • Softstarter device for single-phase models. • Phase controller for three-phase models. • Low susceptibility to clogging with coaxial heat exchanger. • Optimised accessibility to components eases installation and maintenance. • Outdoor ambient temperature controled, to ensure comfort and optimum COP. kW Capacity at outside temp of -7°C* THE + PRODUCTS AN AIRWELL GROUP COMPANY

Open the catalog to page 1
PAC + / PAC + R - 2

FC PAC+ 08-1050-EN:Mise en page 1 10-10-2008 12:10 Pagina 2 AIR/WATER HEAT sous reserve d'obtenKon A TRUE HEAT PUMP OPTIMISED TO RECOVER HEAT FROM THE AIR Exceptionally good COP and high water temperatures with the green optimised performance with coaxial heat exchanger acting against the current in heating mode Heating water input - > Heating water output Diagram: Coaxial heat exchanger A SMOOTH-FIN EVAPORATOR AT A RATE OF 1.8 mm TO EASE THE FLOW OF CONDENSATION AND DEFROSTING WATER A large exchanging surface for SIMPLE ELECTROMAGNETIC EQUIPMENT (NO ELECTRIC DIAGRAM) WITH GLOBALLY...

Open the catalog to page 2

All AIRWELL catalogs and technical brochures

  1. PAC HT

    4 Pages

  2. PAC BT

    8 Pages

  3. 2019 HEATING

    56 Pages

  4. Heating

    80 Pages

  5. NDLP

    1 Pages

  6. DK-DN

    2 Pages

  7. X AR

    2 Pages

  8. AQVL/AQVH

    2 Pages

  9. CWP HP

    2 Pages

  10. MQL / MQH

    2 Pages

  11. VHF

    2 Pages

  12. XLM OG

    2 Pages

  13. AQU@FAN II

    2 Pages

  14. K OG

    4 Pages

  15. CRWC/CRWN

    16 Pages

Archived catalogs

  1. had

    2 Pages

  2. DAKOTA WDI

    4 Pages

  3. SAF 024-045

    2 Pages