Catalogue Facade Systems
www.agrob-buchtal.de
print switch display
Page / 64
Make a request   
AGROB BUCHTAL - 786, 19249, 21647
/ 64
See other catalogues for AGROB BUCHTAL
Text version of the page
50 KerAion Plus
Ceramic composite elements KerAion Plus with invisible fastening
The KerAion Plus composite elements consist of 8 mm thick KerAion base modern panels which are covered with 6 or 8 mm thick ceramic tiles in-plant. The individual building tiles of the surface covering with a maximum side length of 40 cm must not cover more than an area of 0.12 m2 (DIN 18515, Part 1). KerAion Plus is available in diverse standard sizes from 600 x 600 to 1200 x 1200 mm. The grid sizes of the small-size ceramic surface cover­ing are matched to the respective base panel size. Bonding and pointing are carried out by a specially tested technique. The composite elements are non-combustible, building material class A2.
The invisible fastening of the elements is carried out with the proven system KerAion Quadro, which permits the connection to commercially available substructures.
Especially in the field of the protection of historical monuments, at renovations and restorations intended to preserve the original character of small-size building ceramics facades, KerAion Plus offers an ideal solution. But also in the case of new buildings these composite elements offer the possibility of combining the look of smaller ceramic sizes with the fastening technique and the advantages as regards construction physics of rear-ventilated, heat-insulated facade systems.
We will be pleased to verify the technical and economical feasi­bility of these project-specific solutions. Please contact us.
As an enlargement of the existing approvals nos. Z.-33.1.21 and Z-33.1-27, KerAion Plus has the general approval of the super­vising authority by the "Deutsches Institut fur Bautechnik" (German Institute for Structural Engineering).
Administration building, Berlin, Germany
O <
Ceramic composite element
Important:
The use of silicone caoutchoucs must be absolutely avoided, because silicone fluids segregate and effect sticky surfaces on which dirt adheres. Therefore, only use the system components mentioned (foamed piece, EPDM rubber profile, neoprene rub­ber washer) and pointing, bonding and sealing materials recommended by us. We will be pleased to inform you in detail. The usual final cleaning after completion of the construction works is still required.
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-64
pdf-page pdf ae En 2008-10-41-11