Fastening

KeraTwin K12 35

5. Alternatively to the method described in item 4, or for thefastening of single panels, the terminal-clamp can also be used. In this case, only the base plate of the KT clamp is fastened to the bearing profile in accordance with the vertical grid. After the KeraTwin panel has been inserted, a separate clamp lip can be pressed in the base plate and a lateral hole of the KeraTwin panel. For further information, see the standard technical details of thesystem K12 which we will make available to you upon request.

Mounting instructions for KeraTwin K12(clamp fastening KT)

Substructure 4. Atthe last row, the edge-clamps are fastened as describedunder item 1 so that the area can be completed. Two verti- cal rows have to remain open. Two single-clamps are placed between two panels, one panel of the pair of panels is inserted into the already mounted twin-clamps, the other panel into the pre-assembled edge-clamps, pressed with the inserted clamps to the bearing profile, adjusted in height, drilled and fastened by means of stainless steel blind rivets. The mounting of the substructure must be carried out accordingto project-specific, static calculation. The profiles have to be mounted perpendicularly and in a flush way. The distance of the rails in horizontal direction must correspond to the longitudinal grid of the panels. Important: aprofile butt joint of the vertical bearing profilesbehind a panel is not allowed! See standard technical detail drawings. K12 with KT stainless steel clamps on vertical bearingprofiles1. The edge clamps are fastened to the bearing profile bymeans of stainless steel blind rivets* in accordance with the vertical grid of the panels. (For the arrangement of the clamps, see the sketch on page 34) 2. Four self-adhesive foamed pieces are used per panel.Mounting between panel and bearing profile. 3. The panel is put in pre-assembled KT clamps, two single-clamps are inserted on the other side; adjustment in height, drilling and fastening with stainless steel blind rivet. This process is repeated in vertical or horizontal direction.
KeraTwin *Stainless steel blind rivet ø 3.2 x 8 mm with 58 mm grip. Use a mounting tool withextended mouthpiece!
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-64
pdf-page pdf ae En 2008-10-41-12