PVL-136 - 2 Pages

PVL-136
PVL-136
© Copyright 2009 Advanced Green Technologies FLEXPVL1360509
APPLICATION CRITERION
• For installation on approved substrates.
• Installation by certified installers only.
• Installation temperature between
10°C - 40°C (50°F - 100°F)
• Maximum roof temperature 85°C (185°F)
• Minimum slope five eighth inch of fall per
foot (5/8” per foot)
• Maximum slope 21:12
• Refer to manufacturers installation guide for
approved substrates & installation.
IV Curves at various levels of irradiance at
Air Mass 1.5 and 25° C Cell Temperature
ELECTRICAL SPECIFICATIONS for one PVL-136:
Standard Test Conditions (STC)
(1000 W/m2• AM 1.5, 25° C Cell Temperature)
- Maximum Power (Pmax): 136 W
- Voltage at Pmax (Vmp): 33.0 V
- Current at Pmax (Imp): 4.1 A
- Short-circuit Current (Isc): 5.1 A
- Open-circuit Voltage (Voc): 46.2 V
- Maximum Series Fuse Rating: 8 A
Nominal Operating Cell Temperature (NOCT)
(800 W/m2, AM 1.5, 1 m/sec. wind)
- Maximum Power (Pmax): 105 W
- Voltage at Pmax (Vmp): 30.8 V
- Current at Pmax (Imp): 3.42 A
- Short-circuit Current (Isc): 4.1 A
- Open-circuit Voltage (Voc): 42.2 V
- NOCT: 46° C
TEMPERATURE COEFFICIENTS
(at AM 1.5, 1000 W/m2 irradiance)
• Temperature Coefficient of Isc: 5.1 mA/K (0.10%/oC)
• Temperature Coefficient of Imp: 4.1 mA/K (-0.38%/oC)
• Temperature Coefficient of Voc: -176 mV/K (-0.21%/oC)
• Temperature Coefficient of Vmp: -102 mV/K (0.10%/oC)
• Temperature Coefficient of Pmax: -286 mW/K (-0.21%/oC)
NOTES:
1. Actual performance may vary up to 10% from rated power due to low temperature
operation, spectral and other related effects. Maximum system open circuit voltage
not to exceed 600 VDC per UL
2. Electrical specications are based on measurements performed at standard test
conditions of 1000 W/m2 irradiance, Air Mass 1.5, and Cell Temperature of 25°C
after stabilization.
3. During the first 8-10 weeks of operation, electrical output exceeds specified ratings.
4. Power output may be higher by 15%, operating voltage may be higher by 11%
and operating current may be higher by 4%.
5. Specification subject to change without notice.

PVL-136
  1. P. 1

    PVL-136PVL-136Photovoltaic Laminate (PVL) SeriesPERFORMANCE CHARACTERISTICSCONSTRUCTION CHARACTERISTICSQUALIFICATIONS AND SAFETYFEATURES• High Temperature...
  2. P. 2

Text version