OTTdensing and High Efficiency ot Water and Heating Products Mini Product Guide

Open the catalog to page 1
Mini Brochure - 3

Head Office & Distribution, ACV UK ACV UK is a subsidiary of the ACV International Group that has been designing, manufacturing and marketing technological systems for hot water generation since 1922. ACV International was founded in Belgium and pioneered the Tank-in-Tank concept – a cutting edge design providing exceptional performance. All products are manufactured on two production sites in Belgium and in the USA and available through fourteen distributors. ACV has a presence on all five continents. Most ACV products are based on the Tank-in-Tank concept. This technology gives our...

Open the catalog to page 3
Mini Brochure - 4

What is Tank-in-Tank technology? A simple and effective concept delivering outstanding reliable performance. Primary Water The Tank-in-Tank is a DHW tank entirely immersed within an outer tank which contains the primary fluid, with the inner tank itself being a stainless steel heat exchanger. The corrugated wall of the inner tank forms a large heat exchange surface that can heat the domestic water in a very short time. It also provides a uniform temperature throughout the volume of the tank. Since the inner tank can move freely, it can expand and contract under changes in pressure and...

Open the catalog to page 4
Mini Brochure - 5

SmartLine SLE and SLE Plus Fast recovery Tank-in-Tank cylinder – standard 3kW immersion, perfect partner to condensing boilers and heat pumps. ACV has adapted the proven Tank-in-Tank design of the SLE cylinder to maximise its full potential. The addition of multiple ports on the SLE Plus not only gives the installer flexible installation options but also gives the customer a cylinder built with the future in mind! Tank-in-Tank Technology The tried and tested ACV thermal storage technology has proved to be remarkably simple, efficient and reliable. An inner stainless steel hot water cylinder...

Open the catalog to page 5
Mini Brochure - 6

Technical Data SLE SLE SLEPLUS SLE PLUS SLE PLUS Maximum useable input from boiler kW 23 31 39 53 68 Maximum operating pressure Primary: 3 bar Secondary: 10 bar Performance Data SLE SLE SLEPLUS SLEPLUS SLEPLUS Please Note: Performance data assumes a primary flow temperature of85X and a domestic cold water supply of WC High efficiency hot water storage I 5

Open the catalog to page 6
Mini Brochure - 7

SmartLine SL Fast recovery Tank-in-Tank cylinder – perfect partner to condensing boiler. At a time when consumers are demanding higher performance from their hot water installations, the traditional coil based cylinders find it more difficult to deliver high volumes of water for the modern user. ACV Tank-in-Tank technology represents a significant advance in the science of hot water production. A greater heat transfer surface means Tank-in-Tank units recover much faster than any other type of hot water storage cylinder – keeping boiler cycling to a minimum, and ultimately giving improved...

Open the catalog to page 7
Mini Brochure - 8

Technical Data Primary pressure drop mbar 90 95 92 Primary flow rate Ltrs/hr 6200 6400 7200 Maximum useable input from boiler kW 73 88 88 Primary connections (female BSP) 0 1V2" 1V2" 2" Hot water connections (male BSP) 0 1V2" 1V2" 1V2" Maximum operating temperature °C 90 90 90 Maximum operating pressure Primary: 4 bar Secondary: 10 bar Performance Data Litres in first 10 minutes Litres in first 10 minutes Litres in first 10 minutes Litres in first hour Litres in first hour Litres in first hour Initial heat up time 10°C to 85°C Please Note: Performance data assumes a primary flow temperature...

Open the catalog to page 8
Mini Brochure - 9

SmartLine SLME Designed for a range of applications and a multiple choice of energy sources. Multi-Energy cylinder with the advantages of Tank-in-Tank technology and the added benefit of a carbon steel coil located at the bottom in the primary water. The large heating surface area and increased primary volume of the SLME tanks not only increase recovery time, but also ensure all energy from your renewable source is absorbed into the tank, reducing fuel bills and ultimately helping the environment. Due to the unique design of the Multi-Energy cylinder and the large primary thermal store, it...

Open the catalog to page 9
Mini Brochure - 10

Technical Data Max operating pressure heating circuit bar 3 3 3 3 3 3 Max operating pressure DHW circuit bar 10 10 10 10 10 10 Max operating pressure coil circuit bar 10 10 10 10 10 10 Hot water connections 0 3/4" M 3/4" M 3/4" M 3/4" M 3/4" M I'tf'M Immersion heater connection 0 1V2" F 1V2" F 1V2" F 1V2" F 1V2" F Performance Data Heating Source - external boiler connected to tank Please Note: Performance data assumes a primary flow temperature of85X and a domestic cold water supply of I OX High efficiency hot water storage

Open the catalog to page 10
Mini Brochure - 11

Jumbo Fast recovery Tank-in-Tank hot water storage. A large heat exchange surface (1.5 to 2.5 times more than that of a traditional coil) enables the Jumbo to heat a high volume of domestic hot water in a very short time. The unique design of the heat exchanger offers reduced recovery times and improves the overall efficiency and performance of the installation. • Tank-in-Tank floor standing indirect hot water storage tank • Stainless steel construction - no need for sacrificial anodes • High performance - fast heat up and rapid recovery • Fully insulated • Stove enamelled steel casing,...

Open the catalog to page 11
Mini Brochure - 12

Technical Data Jumbo 800 Total capacity Primary capacity Heating surface area Primary pressure drop Hot water connections (male BSP) Maximum useable input from boiler Primary connections (female BSP) Primary flow rate Weight empty Weight full Maximum operating temperature Maximum operating pressure Primary: 5 bar Secondary: 10 bar Performance Data Jumbo 800 Litres in first 10 minutes Litres in first 10 minutes Litres in first 10 minutes Litres in first hour Litres in first hour Litres in first hour Stainless steel inner tank Steel outer tank 120 mm thick mineral wool insulation Primary...

Open the catalog to page 12
Mini Brochure - 13

HeatMaster® 25C Condensing, high performance heating and hot water combination boiler, designed for residential and smaller commercial applications. The HeatMaster 25C brings the benefits of HeatMaster into residential and small commercial applications. ACV’s unique integrated Tank-inTank method of hot water storage ensures the HeatMaster 25C delivers responsive, reliable heating and hot water for all seasons. Higher outputs available on request Responds to high peak demand and high continuous flow • 35 kW input during production of domestic hot water • 365 litres of hot water in the first...

Open the catalog to page 13

All ACV catalogs and technical brochures

  1. E-TECH

    7 Pages

  2. WATERMASTER

    2 Pages

  3. Smart ME

    2 Pages

  4. Heliosplan S

    52 Pages

  5. Comfort

    4 Pages

  6. HeatMaster

    2 Pages

Archived catalogs

  1. SolarMaster

    16 Pages

  2. etech p

    27 Pages

  3. alfaF - FV

    2 Pages

  4. PUFFER – S1

    12 Pages

  5. Compact A

    18 Pages

  6. alfa

    2 Pages