Catalogue PRICES LIST
www.acfri.com
print switch display
Page / 28
Manufacturer's
contact details
ACFRI - 23859, 247687, 18831, 17142, 27500, 19838
/ 28
See all the products ACFRI
Text version of the page

FITTINGS : 3 Garden trolleys TECHNICTECHNIC

-Ext. dimensions L 1466 x P 1400 xH 2270-Depth with building ramp 1485-Int. dimensions L 850 x P 1230 xH 1880-Isolated floor thickness 17 mm withramp-Insulation thickness 70 mm ofpolyurethane-Int. Ext. stainless steel304 l finish -Right hand hinging, left keyboard(inversion on request) -Tension TRI 400 V + T + N-Delivery assembled

GN 1/1 –20 levels - 3 Trolleys 600 x 400 2 Trolleys GN 2/1 –20 levels - 1 Trolley 600 x800Compatible with trolley GN 2/1 Capic, Frima

AR 240 AR 240

STANDARD BLASTSTANDARD BLAST

StandardStandard

-

Electronic controller HACCP with core probe 3 points and independent ambient probe-fan with reinforced waterproof ness-Treated anticorrosion evaporator -Stainless steel back, top, and fan's grid-Contemporary door heating strip-Defrosting and drying of evaporators by resistances and ventilation-Semi isolated stainless steel floor with access ramp manufacturer-New keyboard above the door-Guide-trolley bar Air output : 3 x 6500 = 19 500 m3/H FAST COOLINGCooling in 110 min: 240 kg

Basic series Basic series --AR 240 STD AR 240 STD ––Cycle 110 minutes Cycle 110 minutes

of mashed potato thickness 4.5 cm from + 65 to + 10°C core temperature, + 3°C on average product. Cooling in 90 min : 210 kg of mashed potato thickness 4.5 cm from + 65 to + 10°C core temperature, +3°C on average product. Version 10 hp hermetic remote air cooled home condensing unit

AR 240 STD RD / C110

Ex Works Public price without VAT (Euros) Refrigerating power +32°C amb: Electrical power: Diameter of the connections Aspiration 1”3/8Liquid 5/8” Blast without condensing unit Remote condensing unitBlast + remote condensing unit

17 142

22 807 W at 0 °C 16 238 W at -10°C10 592 W at -20°C Blast with Cond. unit 16900 W

6 240

Performance series Performance series --AR 240 STD AR 240 STD ––Cycle 90 minutes Cycle 90 minutes

FAST COOLING AND OCCASIONAL FREEZINGCooling in 90 min: 240 kg of mashed potato thickness 4.5 cm from + 65 to + 10°C core temperature, + 3°C on average product. Cooling in 110 min: 405 kg of mashed potato thickness 4.5 cm from + 65 to + 10°C core temperature, + 3°C on average product. Freezing in 240 min : 80 kg of mashed potato thickness 4.5 cm from + 65 to -18°C core temperature. Version 10 hp semi hermetic remote air cooled condensing unit

AR 240 STD RD /C90

Refrigerating power +32°C amb Electrical power: Diameter of the connections Blast without condensing unit Remote condensing unitBlast + remote condensing unit 27 310 W at 0°C22 340 W at -10°C 14 650 W at -20°C Blast 5 000 WCond. unit 11 900 W Aspiration 1”3/8Liquid 5/8”

7 530 24 67217 142 23 382

OPTIONSOPTIONS

Ex Works Public price without VAT (Euros) HACCP ELECTRONIC CONTROLLER OPTION BLAST OPTION Printer of the temperatures assembled and cabled in factory 718 €Progressif Temp(3 sequences of blowing during the cycle) 140 € Multi probes (3 coreprobes, incompatible withthe optionProgressif Temp)265 €Traceability solutions Seewithus Additional door759 €Additional controller for second door 229 €Collecting vat of defrost water Free on inquiryStainless steel trolley GN 1/1 -20 levels 585 € Stainless steel trolley 600 x 400 -20 levels 668 €Shelves suppliers GN 1/1 12 €Shelves 600x40016 €Connect‘easy (connector without tool for probe) 72 €Lock26 €Condensing unit options See page 23 and 24 21 UNIT PRICE CLASSICAL WITH TROLLEYS

ACFRI -Z.A. DES BORDES –8, rue Pierre Josse-91070 BONDOUFLE –FRANCE -TEL : 00 33 1 69 11 83 00 –Fax : 00 33 1 60 86 74 77 –E-mail : acfri@acfri.com -http://www.acfri.com

ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf ae En 2009-11-48-24