| Features □ Plug-in unit with CEE plug and phase seguence changeover facility. □ Easily transported and fitted. Compact dimensions allow passage through a standard contemporary door opening. □ Dynamic pressure level sensor on the tank, with separate sensors for inflow level and high water building alarm. □ Trouble-free maintenance thanks to simple removal of the motor housing. □ Five horizontal inlet ports (4 xDN100,1x DN 150) and three vertical (2 xDN100,1x DN 150). Verticalvent line DN 70. Two small diameter ports (DN 40/50) suitable only for wastewater. DN 40 is suitable for connection of a hand membrane pump. □ Discharge Range DN 80, plus Ranged socket with 4" sleeve and clips (fordischarge pipe DN80/100). □ Integrated valve system consisting of two ball-type, nonreturn valves. □ Two pumps; very quiet thanks to 4-pole, slow-running motors. □ Direct contract toilet connection possible in the case of wall-mounted WC units. □ Vortex impeller with large free passage and rear blade mounting, for reliable pumping of both faecal and faecal-free sewage. □ Sloping container floor prevents deposits. □ Built-in mains alarm (visual and acoustic), can be converted to mains-independent by inserting battery. □ Maximum allowable temperature of the medium is 40 °C; or up to 60 °C intermittent (max. 5 minutes). |