Technical Data
AS
Solids
Discharge *
Rated
Motor power **
Rated
Speed
Weight ***
size
voltage
(kW)
current
(mm)
(V)
P1
(A)
(r/min)
(kg)
0530 S12/2W (1
40
G 2"
220-240 1~
1.77
1.20
8.22
2900
31
S12/2D
40
G 2"
400 3~
1.69
1.20
3.29
2900
31
S17/2D
40
G 2"
400 3~
2.31
1.70
3.97
2900
34
S26/2D
40
G 2"
400 3~
3.43
2.60
5.64
2900
40
0630 S10/4W (1
60
DN 65
220-240 1~
1.69
1.00
7.49
1450
37
S13/4D
60
DN 65
400 3~
1.93
1.30
3.60
1450
37
S22/4D
60
DN 65
400 3~
2.88
2.20
5.15
1450
43
0631 S12/2W (1
40
DN 65
220-240 1~
1.77
1.20
8.22
2900
35
S12/2D
40
DN 65
400 3~
1.69
1.20
3.29
2900
35
S17/2W (1
40
DN 65
220-240 1~
2.36
1.65
10.60
2900
35
S17/2D
40
DN 65
400 3~
2.31
1.70
3.97
2900
35
S30/2D
40
DN 65
400 3~
3.74
3.00
6.23
2900
42
0641 S30/2D
45
DN 65
400 3~
3.74
3.00
6.23
2900
41
0830 S10/4W (1
60
DN 80
220-240 1~
1.69
1.00
7.49
1450
40
S13/4D
60
DN 80
400 3~
1.93
1.30
3.60
1450
37
S22/4D
60
DN 80
400 3~
2.88
2.20
5.15
1450
43
0840 S12/2W (1
30
DN 80
220-240 1~
1.77
1.20
8.22
2900
33
S12/2D
30
DN 80
400 3~
1.69
1.20
3.29
2900
33
S17/2D
30
DN 80
400 3~
2.31
1.70
3.97
2900
33
S26/2D
30
DN 80
400 3~
3.43
2.60
5.64
2900
39
* G = internal thread, DN = flange; ** = Power at mains; P2 = Power at motor shaft; *** Weight with 10 m cable; Cable: Standard = 4G1.5, Ex = 7G1.5
1 Start and Run capacitor to the following specification required for use without control panel: Start: 125-160uF (the recommended start time for the motors is two seconds) Run: 40uF [2x20uF] for S10/4W, 30uF for S12/2W and S17/2W
Dimensions (mm)
AS
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
0530 S12/2 & 17/2
432
293
331
160
236
125
175
133
100
18
155
n.a.
20
n.a.
n.a.
S26/2
444
293
331
160
236
125
175
133
100
18
155
n.a.
20
n.a.
n.a.
0630 S10/4 & 13/4
437
309
348
157
294
140
247
147
57
18
245
195
15
132
40
S22/4
450
309
348
157
294
140
247
147
57
18
245
195
15
132
40
0631 S12/2 & 17/2
409
305
346
160
237
140
247
145
54
18
245
195
15
132
40
S30/2
421
305
346
160
237
140
247
145
54
18
245
195
15
132
40
0641 S30/2
428
308
346
160
237
140
247
148
54
18
245
195
15
132
40
0830 S10/4 & 13/42
437
307
305
160
294
200
342
147
88
18
275
195
20
182
25
S22/4
450
307
305
160
294
200
342
147
88
18
275
195
20
182
25
0840 S12/2 & 17/2
418
280
305
130
210
200
342
148
88
18
275
195
20
182
25
S26/2
430
280
305
130
210
200
342
148
88
18
275
195
20
182
25
AS 0530 AS 0630 - 0840
_owest switch-off level; minimum switch-on level must be at least 100 mm higher. AS 0830 & 0840 require full submergence when operating * Elbow not supplied