ABB i-bus
®
ORM1003 Type Optical
Smoke sensor DetailOrder code 2CDG 430 001 R0011 PG 52 MW ** – Type DetailOrder code PG MW ** E1000BREL12NL
Modern detector Base, 12 V,for Series 1000 2CDG 430 006 R0011 52 * – * FPA03 Aerosol, 250 ml GH V902 0012 V0021 52 – E1000RTU >
Optical Smoke Detector
Remote Test Unit for Series 1000 and 300 2CDG 430 007 R0011 52 – >
Electronic Solid-State Siren
The detector base E1000BREL12NL is used together with the optical smoke detector ORM1003 for early detection of fire in buildings. The detector base can be connected to 12 V intruder zones, e.g. zone terminals MT/S 4.12.1 and MT/U 2.12.1. The supply voltage is 12 V DC. A floating two-
way contact serves as an alarm output. An optional reed relay RL in the last detector of the zone monitors the supply voltage and the removal of a smoke detec-
tor from the base. For testing the detector, a testing aerosol or a remote test unit can be used. Electronic solid-state siren with intermittent tone for alarm purposes in indoor installations. RL Reed Relay, 12 V GH V927 0013 V0100 52 – >
SK 0188 B02 SK 0160 B01 SSS GH V927 0001 V0001 50 – SSF/GB >
Combination Signalling Device
GH Q305 0018 R0001 50 – Siren in an aluminium protective housing with additio-nal protective enamel coating and strobe
luminaire mounted on top. Protected against sabotage by a case tamper contact. The alarm inputs are wired onto a terminal
design strip.
VdS Class C. ORM2351 Optical Smoke Detector, programmable 2CDG 430 008 R0011 52 – >
SK 0105 B01 B312NL Detector Base, 12 V, for Series 300 2CDG 430 012 R0011 52 – 2CDG 430 013 R0011 52 – FPA03 Aerosol, 250 ml GH V902 0012 V0021 52 – S300RPTU Remote Programming and Test Unit for Series 300 RL Reed Relay, 12 V GH V927 0013 V0100 50 – >
Optical Smoke Detector, programmable
The detector base B312NL is used together with the optical smoke detector ORM2351 for early detection of fire in buildings. The detector base can be connected to 12 V intruder zones, e.g. zone terminals MT/S 4.12.1 and MT/U 2.12.1. The supply voltage is 12 V DC. A floating two-way contact serves as an alarm output. An optional reed relay RL in the last detector of the zone monitors the supply voltage and the removal of a smoke detector from the base. For testing the detector, a testing aerosol or releasing device can be used. Additionally the ORM 2351 offers a comfortable programming option for the smoke sensitivity in 3 steps and further options. The Remote Programming and Test Unit can also trigger the detector and reads out its degree of pollution. >
2CDC 081 351 F0004 SGL >
GH Q305 0008 R0001 50 – The SGL detector is able to measure and evaluate the concentration of natural gas or liquidfied gas in the air. The detector requires a 10 – 30 V DC voltage supply and has a relay output contact for connection to, for example, the zone terminals. With LED-indicator and Piezo buzzer. >
SK 0101 B01 40
MDRC = Modular DIN-rail Component, SM = Surface Mounting, FM = Flush Mounting, LF = Light Fitting, *PG = Price Group, **MW = Module Width 18 mm