ABB i-bus
®
KNX Illumination and Luminaire Sensors
Type DetailOrder code PG MW ** Type DetailOrder code PG MW ** * * >
Switch/Dim Actuator, 16 A, MDRC EIB-Control Unit for Universal Dimmer, 2-fold, MDRC
Used for switching and dimming of 2, 4 or 8 independent groups of luminaries with electronic ballasts with 1 – 10 V control interfaces. On each channel the power supply of the ballasts can be switched on or off manually or via KNX with a floating load relay (16 A – AC1). Switch status indicator available. Comprehensive range of applications. Using the control module, up to 18 universal dimmers (2 groups with 9 devices) can be controlled via the ABB i-bus >
® 2CDC 071 004 F0007 . Two extension inputs are available for control via external push buttons. >
2CDC 071 243 F0003 6197/11-102-500 6198-0-0102 26 2 SD/S 2.16.1 2-fold2CDG 110 079 R0011 26 4 SD/S 4.16.1 4-fold2CDG 110 080 R0011 26 6 SD/S 8.16.1 8-fold2CDG 110 081 R0011 26 8 >
Universal Dimmer, MDRC
Universal dimmer with light-value memory and minimum brightness memory, soft off function and with intelligence >
Light Controller / Switch/Dim Actuator, 2-fold, 16 A, MDRC
for universal operation. Capacity expansion via output-side, parallel-connectable load lines with power module (max. 6 pcs. = 3000 W/VA 6583-500 >
SK 0068 B98 Master, 500 VA, 230 V, 50/60 Hz 6590-0-0178 total wattage). For incandescent
lamps manufacturers, tungsten-
halogen lamps manufacturer and low-voltage halogen lamps with conventional transformers or electronic transformers. Low-noise, short-circuit-proof, overload-proof. The device enables the switching and dimming of light-ing 19 2 groups using electronic ballasts with an 1 – 10 Vinterface via the ABB i-bus >
® in two independent circuits. 6584-500 Capacity Booster, 420 VA, 6590-0-0179 19 2 >
SK 0110 B99 230 V, 50/60 Hz In combination with the light sensor LF/U 1.1, the device can be used as a 2-fold light controller for constant light control. LR/S 2.2.1 GH Q631 0036 R0111 26 4 DG/S 1.1 2CDG 110 026 R0011 26 4 >
Light Sensor, FM
The light sensor is used for detecting the room brightness level in constant lighting applications in conjunction with the LR/S 2.2.1. Connection is via connecting terminal. >
DALI Gateway, 1-fold, MDRC
The 1-fold DALI gateway DG/S 1.1 is used to interface between DALI and KNX installations. Up to 128 DALI devices can be addressed, whereby 64 devices can be individually switched, dimmed and controlled with a brightness value, via KNX. The second 64 devices operate in broadcast mode or using coded addressing. The DALI functions such as scene control or fault indication can be programmed and activated via the KNX. LF/U 1.1 >
SK 0112 B99 GH Q631 0039 R0111 26 – >
2CDC 071 262 F0005 Switch/Dim Actuator, 1-fold, 10 A, LF
Built-in device for switching and dimming luminaires with electronic ballast via the ABB i-bus >
® . Switching ON/OFF and dimming also possible via conventional push buttons. DG/S 8.1 2CDG 110 025 R0011 26 6 >
SK 0073 B95 DALI Gateway, 8-fold, MDRC
6153 EB-500 6153-0-0027 26 – For controlling DALI devices (electronic ballasts, transformers etc.) via the ABB i-bus >
® . There are 8 separate, independent DALI outputs/
channels available. Up to 16 DALI devices can be connected per channel with a maximum of 128 devices per gateway. The functions of switching, dimming, set values and fault indication for lamps and electronic ballasts are available for each output. It is possible to set the lamp burn-in time and 16 lightscenes. The addressing or commissioning of the DALI devices is not necessary. >
2CDC 071 131 F0004 Switch/Dim Actuator/Sensor, 1-fold, 10 A, FM
FM Switch/Dim Actuator, 1-fold, 230 V , 50 Hz, 10 AX,cos phi 0.5. Bus coupler with 0 – 10 V interface for switching and dimming luminaires with electronic ballast via the ABB i-bus >
® SK 0128 B02 . 6114 U-500 6151-0-0177 26 – DSA/S 2.16.1 >
Universal Dim Actuator, 2-fold, 300 VA, MDRC DALI Switch Actuator, 2-fold, 16 AX, C-load, MDRC
2CDG 110 009 R0011 26 4 For switching and dimming of incandescent lamps, 230 V halogen lamps or low-voltage halogen lamps which are powered by wound or electronic transformers (automatic load detection). Output power 2 x 300 VA or 1 x 500 VA up to 45°C ambient temperature. Both outputs are independ-
ent of one another and can be supplied by different phases. Comprehensive application program with scene and time functions. Uses potential free contacts to switch 2 in dependent electrical loads via DALI control (Digital Addressable Lighting Interface). For use in conjunction with the DALI Gateways DG/S. Manual operation and display of the switching state of the contacts. The 16 AX-AC3 (C-Load) device is especially suitable for loads with high surge currents e.g. fluorescent lighting (AX) acc. EN 60669. >
May 2008 2CDC 821 001 F0005 UD/S 2.300.2 2CDG 110 074 R0011 26 4 >
Universal Dim Actuator, 1-fold, 400 VA, LF Control Unit for LUXCONTROL, MDRC
Built-in device for switching and dimming incandes-cent lamps and 230 V halogen lamps via the ABB i-bus The controller is used to control digitally dimmable devices with electronic ballast or transformers from the ABB range via the ABB i-bus >
SK 0076 B95 ® . Switching ON/OFF and dimming also possible via conventional push buttons. >
® . A maximum of 50 devices with electronic ballast can be connected in a lighting circuit. >
SK 0012 B98 6155 EB-101-500 6151-0-0062 26 – SL/S 50.1 GH Q605 0051 R0001 20 4 >
22